-
1
-
-
0035869712
-
A prospective study of salivary function sparing in patients with head and neck cancers receiving intensity-modulated or three dimensional radiation therapy: initial results
-
Chao K.S., Deasy J.O., Markman J., et al. A prospective study of salivary function sparing in patients with head and neck cancers receiving intensity-modulated or three dimensional radiation therapy: initial results. Int J Radiat Oncol Biol Phys 49 (2001) 907-916
-
(2001)
Int J Radiat Oncol Biol Phys
, vol.49
, pp. 907-916
-
-
Chao, K.S.1
Deasy, J.O.2
Markman, J.3
-
2
-
-
13844254871
-
The impact of daily set-up variations on head and neck intensity modulated radiation therapy
-
Hong T.S., Tome W.A., Chappell R.J., Chinnaiyan P., Mehta M.P., and Harari P.M. The impact of daily set-up variations on head and neck intensity modulated radiation therapy. Int J Radiat Oncol Biol Phys 61 (2005) 779-788
-
(2005)
Int J Radiat Oncol Biol Phys
, vol.61
, pp. 779-788
-
-
Hong, T.S.1
Tome, W.A.2
Chappell, R.J.3
Chinnaiyan, P.4
Mehta, M.P.5
Harari, P.M.6
-
3
-
-
0035425538
-
A protocol for the reduction of systematic patient setup errors with minimal portal imaging workload
-
de Boer H.C., and Heijmen B.J. A protocol for the reduction of systematic patient setup errors with minimal portal imaging workload. Int J Radiat Oncol Biol Phys 50 (2001) 1350-1365
-
(2001)
Int J Radiat Oncol Biol Phys
, vol.50
, pp. 1350-1365
-
-
de Boer, H.C.1
Heijmen, B.J.2
-
5
-
-
0034237797
-
The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy
-
van Herk M.P., Remeijer P., Rasch C., and Lebesque J.V. The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. Int J Radiat Oncol Biol Phys 47 (2000) 1121-1135
-
(2000)
Int J Radiat Oncol Biol Phys
, vol.47
, pp. 1121-1135
-
-
van Herk, M.P.1
Remeijer, P.2
Rasch, C.3
Lebesque, J.V.4
-
6
-
-
0346106247
-
When should systematic patient positioning errors in radiotherapy be corrected
-
Bortfeld T., van Herk M., and Jiang S.B. When should systematic patient positioning errors in radiotherapy be corrected. Phys Med Biol 47 23 (2002) N297-N302
-
(2002)
Phys Med Biol
, vol.47
, Issue.23
-
-
Bortfeld, T.1
van Herk, M.2
Jiang, S.B.3
-
7
-
-
39749094602
-
Evaluation of image-guidance strategies in the treatment of localized prostate cancer
-
Kupelian P.A., Lee C., Langen K.M., et al. Evaluation of image-guidance strategies in the treatment of localized prostate cancer. Int J Radiat Oncol Biol Phys 70 4 (2008) 1151-1157
-
(2008)
Int J Radiat Oncol Biol Phys
, vol.70
, Issue.4
, pp. 1151-1157
-
-
Kupelian, P.A.1
Lee, C.2
Langen, K.M.3
-
8
-
-
51049113795
-
Optimisation du processus d'imagerie de haute énergie (MVCT) pour la tomothérapie hélicoïdale des cancers de la prostate
-
Beldjoudi G., Yartsev S., Battista J.J., and Van Dyk J. Optimisation du processus d'imagerie de haute énergie (MVCT) pour la tomothérapie hélicoïdale des cancers de la prostate. Cancer Radiother 12 5 (2008) 316-322
-
(2008)
Cancer Radiother
, vol.12
, Issue.5
, pp. 316-322
-
-
Beldjoudi, G.1
Yartsev, S.2
Battista, J.J.3
Van Dyk, J.4
-
9
-
-
27144446357
-
Assessment of a customised immobilisation system for head and neck IMRT using electronic portal imaging
-
Humphreys M., Guerrero Urbano M.T., Mubata C., et al. Assessment of a customised immobilisation system for head and neck IMRT using electronic portal imaging. Radiother Oncol 77 (2005) 39-44
-
(2005)
Radiother Oncol
, vol.77
, pp. 39-44
-
-
Humphreys, M.1
Guerrero Urbano, M.T.2
Mubata, C.3
-
10
-
-
33846842265
-
Evaluation of image-guidance protocols in the treatment of head and neck cancers
-
Zeidan O.A., Langen K.M., Meeks S.L., et al. Evaluation of image-guidance protocols in the treatment of head and neck cancers. Int J Radiat Oncol Biol Phys 67 (2007) 670-677
-
(2007)
Int J Radiat Oncol Biol Phys
, vol.67
, pp. 670-677
-
-
Zeidan, O.A.1
Langen, K.M.2
Meeks, S.L.3
-
12
-
-
0035252566
-
Comparison of set-up accuracy of three different thermoplastic masks for the treatment of brain and head and neck tumours
-
Gilbeau L., Octave-Prignot M., Loncol T., Renard L., Scalliet P., and Gregoire V. Comparison of set-up accuracy of three different thermoplastic masks for the treatment of brain and head and neck tumours. Radiother Oncol 58 (2001) 155-162
-
(2001)
Radiother Oncol
, vol.58
, pp. 155-162
-
-
Gilbeau, L.1
Octave-Prignot, M.2
Loncol, T.3
Renard, L.4
Scalliet, P.5
Gregoire, V.6
-
13
-
-
33645989447
-
Analysis of interfractional set-up errors and intrafractional organ motions during IMRT for head and neck tumours to define an appropriate planning target volume (PTV) and planning organs at risk volume (PRV) margins
-
Suzuki M., Nishimura Y., Nakamatsu K., et al. Analysis of interfractional set-up errors and intrafractional organ motions during IMRT for head and neck tumours to define an appropriate planning target volume (PTV) and planning organs at risk volume (PRV) margins. Radiother Oncol 78 (2006) 283-290
-
(2006)
Radiother Oncol
, vol.78
, pp. 283-290
-
-
Suzuki, M.1
Nishimura, Y.2
Nakamatsu, K.3
-
14
-
-
43049174612
-
Patterns of failure and toxicity after intensity modulated radiotherapy for head and neck cancer
-
Schoenfield G.O., Amdur R.J., Morris C.G., Li J.G., Hinerman R.W., and Mendenhall W.M. Patterns of failure and toxicity after intensity modulated radiotherapy for head and neck cancer. Int J Radiat Oncol Biol Phys 71 (2008) 377-385
-
(2008)
Int J Radiat Oncol Biol Phys
, vol.71
, pp. 377-385
-
-
Schoenfield, G.O.1
Amdur, R.J.2
Morris, C.G.3
Li, J.G.4
Hinerman, R.W.5
Mendenhall, W.M.6
-
15
-
-
33746834078
-
Limitations of the planning organ at risk volume (PRV) concept
-
Stroom J.C., and Heijmen B.J. Limitations of the planning organ at risk volume (PRV) concept. Int J Radiat Oncol Biol Phys 66 (2006) 279-286
-
(2006)
Int J Radiat Oncol Biol Phys
, vol.66
, pp. 279-286
-
-
Stroom, J.C.1
Heijmen, B.J.2
-
16
-
-
63649160518
-
Dose-volume population histogram: a new tool for evaluating plans whilst considering geometrical uncertainties
-
Nguyen T.B., Hoole A.C.F., Burnet N.G., and Thomas S.J. Dose-volume population histogram: a new tool for evaluating plans whilst considering geometrical uncertainties. Phys Med Biol 54 4 (2009) 935-947
-
(2009)
Phys Med Biol
, vol.54
, Issue.4
, pp. 935-947
-
-
Nguyen, T.B.1
Hoole, A.C.F.2
Burnet, N.G.3
Thomas, S.J.4
-
17
-
-
0036229217
-
Margins for geometric uncertainty around organs at risk in radiotherapy
-
McKenzie A., van Herk M., and Mijnheer. Margins for geometric uncertainty around organs at risk in radiotherapy. Radiother Oncol 62 (2002) 299-307
-
(2002)
Radiother Oncol
, vol.62
, pp. 299-307
-
-
McKenzie, A.1
van Herk, M.2
Mijnheer3
|