1
-
-
0003418872
-
-
International Commission on Radiation Units and Measurements, ICRU Publications, Bethesda, MD
-
International Commission on Radiation Units and Measurements. ICRU Report 50. Prescribing, recording, and reporting photon beam therapy (1993), ICRU Publications, Bethesda, MD
-
(1993)
ICRU Report 50. Prescribing, recording, and reporting photon beam therapy
-
-
-
2
-
-
0003418875
-
-
International Commission on Radiation Units and Measurements, ICRU, Bethesda, MD
-
International Commission on Radiation Units and Measurements. ICRU Report 62. Prescribing, recording, and reporting photon beam therapy (Supplement to ICRU Report 50) (1999), ICRU, Bethesda, MD
-
(1999)
ICRU Report 62. Prescribing, recording, and reporting photon beam therapy (Supplement to ICRU Report 50)
-
-
-
3
-
-
0036229217
-
Margins for geometric uncertainty around organs at risk in radiotherapy
-
McKenzie A., van Herk M., and Mijnheer B. Margins for geometric uncertainty around organs at risk in radiotherapy. Radiother Oncol 62 (2002) 299-307
-
(2002)
Radiother Oncol
, vol.62
, pp. 299-307
-
-
McKenzie, A.1
van Herk, M.2
Mijnheer, B.3
-
4
-
-
0842324877
-
On the use of margins for geometrical uncertainties around the rectum in radiotherapy planning
-
Muren L.P., Ekerold R., Kvinnsland Y., et al. On the use of margins for geometrical uncertainties around the rectum in radiotherapy planning. Radiother Oncol 70 (2004) 11-19
-
(2004)
Radiother Oncol
, vol.70
, pp. 11-19
-
-
Muren, L.P.1
Ekerold, R.2
Kvinnsland, Y.3
-
5
-
-
0026745010
-
Maximizing setup accuracy using portal images as applied to a conformal boost technique for prostatic cancer
-
Bijhold J., Lebesque J.V., Hart A.A., et al. Maximizing setup accuracy using portal images as applied to a conformal boost technique for prostatic cancer. Radiother Oncol 24 (1992) 261-271
-
(1992)
Radiother Oncol
, vol.24
, pp. 261-271
-
-
Bijhold, J.1
Lebesque, J.V.2
Hart, A.A.3
-
6
-
-
0036661305
-
Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report
-
Stroom J.C., and Heijmen B.J. Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report. Radiother Oncol 64 (2002) 75-83
-
(2002)
Radiother Oncol
, vol.64
, pp. 75-83
-
-
Stroom, J.C.1
Heijmen, B.J.2
-
7
-
-
0033041247
-
Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability
-
Stroom J.C., de Boer H.C., Huizenga H., et al. Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability. Int J Radiat Oncol Biol Phys 43 (1999) 905-919
-
(1999)
Int J Radiat Oncol Biol Phys
, vol.43
, pp. 905-919
-
-
Stroom, J.C.1
de Boer, H.C.2
Huizenga, H.3
-
8
-
-
0023132335
-
Implementation of random positioning error in computerised radiation treatment planning systems as a result of fractionation
-
Leong J. Implementation of random positioning error in computerised radiation treatment planning systems as a result of fractionation. Phys Med Biol 32 (1987) 327-334
-
(1987)
Phys Med Biol
, vol.32
, pp. 327-334
-
-
Leong, J.1
-
9
-
-
22444449581
-
Testing the new ICRU 62 'Planning Organ at Risk Volume' concept for the rectum
-
Muren L.P., Karlsdottir A., Kvinnsland Y., et al. Testing the new ICRU 62 'Planning Organ at Risk Volume' concept for the rectum. Radiother Oncol 75 (2005) 293-302
-
(2005)
Radiother Oncol
, vol.75
, pp. 293-302
-
-
Muren, L.P.1
Karlsdottir, A.2
Kvinnsland, Y.3
-
10
-
-
0043066889
-
Unexpected changes of rat cervical spinal cord tolerance caused by inhomogeneous dose distributions
-
Bijl H.P., van Luijk P., Coppes R.P., et al. Unexpected changes of rat cervical spinal cord tolerance caused by inhomogeneous dose distributions. Int J Radiat Oncol Biol Phys 57 (2003) 274-281
-
(2003)
Int J Radiat Oncol Biol Phys
, vol.57
, pp. 274-281
-
-
Bijl, H.P.1
van Luijk, P.2
Coppes, R.P.3
-
11
-
-
33746851796
-
Predicting dose uncertainty in moving organs at risk
-
Yi B.Y., Ahn S.D., Choi E.K., and Ha S.W. (Eds), Jeong Publishing, Seoul
-
Stroom J., Lebesque J., van Herk M., et al. Predicting dose uncertainty in moving organs at risk. In: Yi B.Y., Ahn S.D., Choi E.K., and Ha S.W. (Eds). Proceedings of the XIVth International Conference on the Use of Computers in Radiation Therapy (2004), Jeong Publishing, Seoul 86-88
-
(2004)
Proceedings of the XIVth International Conference on the Use of Computers in Radiation Therapy
, pp. 86-88
-
-
Stroom, J.1
Lebesque, J.2
van Herk, M.3
-
12
-
-
0033039065
-
Acute morbidity reduction using 3DCRT for prostate carcinoma. A randomized study
-
Koper P.C., Stroom J.C., van Putten W.L., et al. Acute morbidity reduction using 3DCRT for prostate carcinoma. A randomized study. Int J Radiat Oncol Biol Phys 43 (1999) 727-734
-
(1999)
Int J Radiat Oncol Biol Phys
, vol.43
, pp. 727-734
-
-
Koper, P.C.1
Stroom, J.C.2
van Putten, W.L.3
|