메뉴 건너뛰기




Volumn 61, Issue 3, 2005, Pages 779-788

The impact of daily setup variations on head-and-neck intensity-modulated radiation therapy

Author keywords

Head and neck cancer; Intensity modulated radiation therapy; Set up variation

Indexed keywords

DEGREES OF FREEDOM (MECHANICS); FRACTURE FIXATION; ONCOLOGY; PATIENT MONITORING; PATIENT TREATMENT; RADIOTHERAPY; TISSUE; TOXICITY; TUMORS;

EID: 13844254871     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2004.07.696     Document Type: Article
Times cited : (234)

References (38)
  • 1
    • 0028938971 scopus 로고
    • Accuracy of field alignment in radiotherapy of head and neck cancer utilizing individualized face mask immobilization--a retrospective analysis of clinical practice
    • C.F. Hess, R.D. Kortmann, R. Jany Accuracy of field alignment in radiotherapy of head and neck cancer utilizing individualized face mask immobilization--a retrospective analysis of clinical practice Radiother Oncol 34 1995 69 72
    • (1995) Radiother Oncol , vol.34 , pp. 69-72
    • Hess, C.F.1    Kortmann, R.D.2    Jany, R.3
  • 2
    • 0036318477 scopus 로고    scopus 로고
    • Dose-volume specification: New challenges with intensity-modulated radiation therapy
    • J.A. Purdy Dose-volume specification: New challenges with intensity-modulated radiation therapy Semin Radiat Oncol 12 2002 199 209
    • (2002) Semin Radiat Oncol , vol.12 , pp. 199-209
    • Purdy, J.A.1
  • 3
    • 0033985180 scopus 로고    scopus 로고
    • Future directions in 3-D treatment planning and delivery: A physicist's perspective
    • J.A. Purdy Future directions in 3-D treatment planning and delivery: A physicist's perspective Int J Radiat Oncol Biol Phys 46 2000 3 6
    • (2000) Int J Radiat Oncol Biol Phys , vol.46 , pp. 3-6
    • Purdy, J.A.1
  • 4
    • 0036680295 scopus 로고    scopus 로고
    • Determination and delineation of nodal target volumes for head-and-neck cancer based on patterns of failure in patients receiving definitive and postoperative IMRT
    • K.S. Chao, F.J. Wippold, G. Ozyigit Determination and delineation of nodal target volumes for head-and-neck cancer based on patterns of failure in patients receiving definitive and postoperative IMRT Int J Radiat Oncol Biol Phys 53 2002 1174 1184
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 1174-1184
    • Chao, K.S.1    Wippold, F.J.2    Ozyigit, G.3
  • 5
    • 0342588064 scopus 로고    scopus 로고
    • Selection and delineation of lymph node target volumes in head and neck conformal radiotherapy: Proposal for standardizing terminology and procedure based on surgical experience
    • V. Gregoire, E. Coche, G. Cosnard Selection and delineation of lymph node target volumes in head and neck conformal radiotherapy: Proposal for standardizing terminology and procedure based on surgical experience Radiother Oncol 56 2000 135 150
    • (2000) Radiother Oncol , vol.56 , pp. 135-150
    • Gregoire, V.1    Coche, E.2    Cosnard, G.3
  • 6
    • 0032788053 scopus 로고    scopus 로고
    • A three dimensional CT-based target definition for elective irradiation of the neck
    • P.J. Nowak, O.B. Wijers, F.J. Lagerwaard A three dimensional CT-based target definition for elective irradiation of the neck Int J Radiat Oncol Biol Phys 45 1999 33 39
    • (1999) Int J Radiat Oncol Biol Phys , vol.45 , pp. 33-39
    • Nowak, P.J.1    Wijers, O.B.2    Lagerwaard, F.J.3
  • 7
    • 0032843202 scopus 로고    scopus 로고
    • A simplified CT-based definition of the lymph node levels in the node negative neck
    • O.B. Wijers, P.C. Levendag, T. Tan A simplified CT-based definition of the lymph node levels in the node negative neck Radiother Oncol 52 1999 25 42
    • (1999) Radiother Oncol , vol.52 , pp. 25-42
    • Wijers, O.B.1    Levendag, P.C.2    Tan, T.3
  • 8
    • 0032900493 scopus 로고    scopus 로고
    • An imaging-based classification of the cervical nodes designed as an adjunct to recent clinically based nodal classifications
    • P.M. Som, S.D. Curtin, A.A. Mancuso An imaging-based classification of the cervical nodes designed as an adjunct to recent clinically based nodal classifications Arch Otolaryngol Head Neck Surg 125 1999 388 396
    • (1999) Arch Otolaryngol Head Neck Surg , vol.125 , pp. 388-396
    • Som, P.M.1    Curtin, S.D.2    Mancuso, A.A.3
  • 9
    • 0032850759 scopus 로고    scopus 로고
    • Dose, volume, and function relationships in parotid salivary glands following conformal and intensity-modulated irradiation of head-and-neck cancer
    • A. Eisbruch, R.K.T. Haken, H.M. Kim Dose, volume, and function relationships in parotid salivary glands following conformal and intensity-modulated irradiation of head-and-neck cancer Int J Radiat Oncol Biol Phys 45 1999 577 587
    • (1999) Int J Radiat Oncol Biol Phys , vol.45 , pp. 577-587
    • Eisbruch, A.1    Haken, R.K.T.2    Kim, H.M.3
  • 10
    • 0030248816 scopus 로고    scopus 로고
    • Parotid gland sparing in patients undergoing bilateral head and neck irradiation: Techniques and early results
    • A. Eisbruch, J.A. Ship, M.K. Martel Parotid gland sparing in patients undergoing bilateral head and neck irradiation: Techniques and early results Int J Radiat Oncol Biol Phys 36 1996 469 480
    • (1996) Int J Radiat Oncol Biol Phys , vol.36 , pp. 469-480
    • Eisbruch, A.1    Ship, J.A.2    Martel, M.K.3
  • 11
    • 0037358291 scopus 로고    scopus 로고
    • Intensity-modulated radiation therapy (IMRT) for locally advanced paranasal sinus tumors: Incorporating clinical decisions in the optimization process
    • C. Tsien, A. Eisbruch, D. McShan Intensity-modulated radiation therapy (IMRT) for locally advanced paranasal sinus tumors: Incorporating clinical decisions in the optimization process Int J Radiat Oncol Biol Phys 55 2003 776 784
    • (2003) Int J Radiat Oncol Biol Phys , vol.55 , pp. 776-784
    • Tsien, C.1    Eisbruch, A.2    McShan, D.3
  • 12
    • 20244364349 scopus 로고    scopus 로고
    • Treatment planning and delivery of intensity-modulated radiation therapy for primary nasopharynx cancer
    • M.A. Hunt, M.J. Zelefsky, S. Wolden Treatment planning and delivery of intensity-modulated radiation therapy for primary nasopharynx cancer Int J Radiat Oncol Biol Phys 49 2001 623 632
    • (2001) Int J Radiat Oncol Biol Phys , vol.49 , pp. 623-632
    • Hunt, M.A.1    Zelefsky, M.J.2    Wolden, S.3
  • 13
    • 0028215864 scopus 로고
    • Quality assurance in fractionated stereotactic radiotherapy
    • A.P. Warrington, R.W. Laing, M. Brada Quality assurance in fractionated stereotactic radiotherapy Radiother Oncol 30 1994 239 246
    • (1994) Radiother Oncol , vol.30 , pp. 239-246
    • Warrington, A.P.1    Laing, R.W.2    Brada, M.3
  • 14
    • 0026480610 scopus 로고
    • Computer systems and mechanical tools for stereotactically guided conformation therapy with linear accelerators
    • W. Schlegel, O. Pastyr, T. Boertfeld Computer systems and mechanical tools for stereotactically guided conformation therapy with linear accelerators Int J Radiat Oncol Biol Phys 24 1992 781 787
    • (1992) Int J Radiat Oncol Biol Phys , vol.24 , pp. 781-787
    • Schlegel, W.1    Pastyr, O.2    Boertfeld, T.3
  • 15
    • 0029806583 scopus 로고    scopus 로고
    • Pelizzari Repositioning accuracy of a noninvasive head fixation system using a stereotactic head mask
    • R.J. Hamilton, F.T. Kuchnir, Pelizzari Repositioning accuracy of a noninvasive head fixation system using a stereotactic head mask Med Phys 23 1996 1909 1917
    • (1996) Med Phys , vol.23 , pp. 1909-1917
    • Hamilton, R.J.1    Kuchnir, F.T.2
  • 16
    • 0035312748 scopus 로고    scopus 로고
    • Three-dimensional accuracy and interfractional reproducibility of patient fixation and positioning using a stereotactic head mask system
    • C.P. Karger, O. Kaekel, J. Debus Three-dimensional accuracy and interfractional reproducibility of patient fixation and positioning using a stereotactic head mask system Int J Radiat Oncol Biol Phys 49 2001 1493 1504
    • (2001) Int J Radiat Oncol Biol Phys , vol.49 , pp. 1493-1504
    • Karger, C.P.1    Kaekel, O.2    Debus, J.3
  • 17
    • 0035479374 scopus 로고    scopus 로고
    • The TALON removable head frame system for stereotactic radiosurgery/radiotherapy: Measurement for repositioning accuracy
    • B.J. Salter, M. Fuss, D.G. Vollmer The TALON removable head frame system for stereotactic radiosurgery/radiotherapy: Measurement for repositioning accuracy Int J Radiat Oncol Biol Phys 51 2001 555 562
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 555-562
    • Salter, B.J.1    Fuss, M.2    Vollmer, D.G.3
  • 18
    • 0036627977 scopus 로고    scopus 로고
    • Fractionated stereotactic radiotherapy: A short review
    • W.A. Tomé, M.P. Mehta, S.L. Meeks Fractionated stereotactic radiotherapy: A short review Technol Res Treat 1; 2002 153 172
    • (2002) Technol Res Treat , vol.1 , pp. 153-172
    • Tomé, W.A.1    Mehta, M.P.2    Meeks, S.L.3
  • 19
    • 0036800554 scopus 로고    scopus 로고
    • The effect of set-up uncertainties, contour changes, and tissue in homogeneities on target dose volume histograms
    • B.C.J. Cho, M. van Herk, B.J. Mijner The effect of set-up uncertainties, contour changes, and tissue in homogeneities on target dose volume histograms Med Phys 29 2002 2305 2318
    • (2002) Med Phys , vol.29 , pp. 2305-2318
    • Cho, B.C.J.1    Van Herk, M.2    Mijner, B.J.3
  • 20
    • 0035996471 scopus 로고    scopus 로고
    • On cold spots in tumor subvolumes
    • W.A. Tomé, J.F. Fowler On cold spots in tumor subvolumes Med Phys 29 2002 1590 1598
    • (2002) Med Phys , vol.29 , pp. 1590-1598
    • Tomé, W.A.1    Fowler, J.F.2
  • 21
    • 0028142075 scopus 로고
    • Reproducibility of field alignment in difficult patient positioning
    • R.D. Kortmann, C.F. Hess, R. Jany Reproducibility of field alignment in difficult patient positioning Int J Radiat Oncol Biol Phys 29 1994 869 872
    • (1994) Int J Radiat Oncol Biol Phys , vol.29 , pp. 869-872
    • Kortmann, R.D.1    Hess, C.F.2    Jany, R.3
  • 22
    • 0028952712 scopus 로고
    • Is the standardized helmet technique adequate for irradiation of the brain and the cranial meninges?
    • R.D. Kortmann, C.F. Hess, W. Hoffman Is the standardized helmet technique adequate for irradiation of the brain and the cranial meninges? Int J Radiat Oncol Biol Phys 32 1995 241 244
    • (1995) Int J Radiat Oncol Biol Phys , vol.32 , pp. 241-244
    • Kortmann, R.D.1    Hess, C.F.2    Hoffman, W.3
  • 23
    • 0032903601 scopus 로고    scopus 로고
    • HIT '91 (prospective, co-operative study for the treatment of malignant brain tumors in childhood): Accuracy and acute toxicity of the irradiation of the craniospinal axis--results of the quality assurance program
    • R.D. Kortmann, B. Timmermann, J. Kuhl HIT '91 (prospective, co-operative study for the treatment of malignant brain tumors in childhood): Accuracy and acute toxicity of the irradiation of the craniospinal axis--results of the quality assurance program Strahlenther Onkol 175 1999 162 169
    • (1999) Strahlenther Onkol , vol.175 , pp. 162-169
    • Kortmann, R.D.1    Timmermann, B.2    Kuhl, J.3
  • 24
    • 17444451753 scopus 로고    scopus 로고
    • Three dimensional variability in patient positioning using bite block immobilization in 3D conformal radiation treatment for ENT-tumors
    • J. Willner, U. Hadinger, M. Neumann Three dimensional variability in patient positioning using bite block immobilization in 3D conformal radiation treatment for ENT-tumors Radiother Oncol 43 1997 315 321
    • (1997) Radiother Oncol , vol.43 , pp. 315-321
    • Willner, J.1    Hadinger, U.2    Neumann, M.3
  • 25
    • 0035252342 scopus 로고    scopus 로고
    • Set-up verification using portal imaging; Review of current clinical practice
    • C.W. Hurkmans, P. Remeijer, J.V. Lebesque Set-up verification using portal imaging; review of current clinical practice Radiother Oncol 58 2001 105 120
    • (2001) Radiother Oncol , vol.58 , pp. 105-120
    • Hurkmans, C.W.1    Remeijer, P.2    Lebesque, J.V.3
  • 26
    • 0035252566 scopus 로고    scopus 로고
    • Comparison of setup accuracy of three different thermoplastic masks for the treatment of brain and head and neck tumors
    • L. Gilbeau, M. Octave-Prignot, T. Loncol Comparison of setup accuracy of three different thermoplastic masks for the treatment of brain and head and neck tumors Radiother Oncol 58 2001 155 162
    • (2001) Radiother Oncol , vol.58 , pp. 155-162
    • Gilbeau, L.1    Octave-Prignot, M.2    Loncol, T.3
  • 28
    • 0027991368 scopus 로고
    • Photogrammetric accuracy measurements of head holder systems used for fractionated radiotherapy
    • M. Menke, F. Hirschfeld, T. Mack Photogrammetric accuracy measurements of head holder systems used for fractionated radiotherapy Int J Radiat Oncol Biol Phys 29 1994 1147 1155
    • (1994) Int J Radiat Oncol Biol Phys , vol.29 , pp. 1147-1155
    • Menke, M.1    Hirschfeld, F.2    MacK, T.3
  • 29
    • 0034811788 scopus 로고    scopus 로고
    • Optically guided intensity modulated radiotherapy
    • W.A. Tomé, S.L. Meeks, T.R. McNutt Optically guided intensity modulated radiotherapy Radiother Oncol 61 2001 33 44
    • (2001) Radiother Oncol , vol.61 , pp. 33-44
    • Tomé, W.A.1    Meeks, S.L.2    McNutt, T.R.3
  • 30
    • 0034653771 scopus 로고    scopus 로고
    • Image localization for frameless stereotactic radiotherapy
    • S.L. Meeks, F.J. Bova, T.H. Wagner Image localization for frameless stereotactic radiotherapy Int J Radiat Biol Phys 46 2000 1291 1299
    • (2000) Int J Radiat Biol Phys , vol.46 , pp. 1291-1299
    • Meeks, S.L.1    Bova, F.J.2    Wagner, T.H.3
  • 32
    • 0035577194 scopus 로고    scopus 로고
    • The effect of setup uncertainty on normal tissue sparing with IMRT for head-and-neck cancer
    • M.A. Manning, Q. Wu, R.M. Cardinale The effect of setup uncertainty on normal tissue sparing with IMRT for head-and-neck cancer Int J Radiat Biol Phys 51 2001 1400 1409
    • (2001) Int J Radiat Biol Phys , vol.51 , pp. 1400-1409
    • Manning, M.A.1    Wu, Q.2    Cardinale, R.M.3
  • 33
    • 0034004037 scopus 로고    scopus 로고
    • Treatment planning algorithm corrections accounting for random setup uncertainties in fractionated stereotactic radiotherapy
    • S.F. Zavgorodni Treatment planning algorithm corrections accounting for random setup uncertainties in fractionated stereotactic radiotherapy Med Phys 27 2000 685 690
    • (2000) Med Phys , vol.27 , pp. 685-690
    • Zavgorodni, S.F.1
  • 34
    • 0037037771 scopus 로고    scopus 로고
    • A fluence-convolution method to calculate radiation therapy dose distributions that incorporate random set-up error
    • W.A. Beckham, P.J. Keall, J.V. Diebers A fluence-convolution method to calculate radiation therapy dose distributions that incorporate random set-up error Phys Med Biol 47 2002 3465 3473
    • (2002) Phys Med Biol , vol.47 , pp. 3465-3473
    • Beckham, W.A.1    Keall, P.J.2    Diebers, J.V.3
  • 35
    • 0037297108 scopus 로고    scopus 로고
    • Patterns of failure in patients receiving definitive and postoperative IMRT for head-and-neck cancer
    • K.S. Chao, G. Ozyigit, B.N. Tran Patterns of failure in patients receiving definitive and postoperative IMRT for head-and-neck cancer Int J Radiat Oncol Biol Phys 55 2002 312 321
    • (2002) Int J Radiat Oncol Biol Phys , vol.55 , pp. 312-321
    • Chao, K.S.1    Ozyigit, G.2    Tran, B.N.3
  • 36
    • 0036569761 scopus 로고    scopus 로고
    • Intensity-modulated radiotherapy in the treatment of nasopharyngeal carcinoma: An update of the UCSF experience
    • N. Lee, P. Xia, J.M. Quivey Intensity-modulated radiotherapy in the treatment of nasopharyngeal carcinoma: An update of the UCSF experience Int J Radiat Oncol Biol Phys 53 2002 12 22
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 12-22
    • Lee, N.1    Xia, P.2    Quivey, J.M.3
  • 37
    • 0034024133 scopus 로고    scopus 로고
    • Intensity-modulated radiation therapy in head and neck cancer: The Mallinckrodt experience
    • K.S. Chao, D.A. Low, C.A. Perez Intensity-modulated radiation therapy in head and neck cancer: The Mallinckrodt experience Int J Cancer 90 2000 92 103
    • (2000) Int J Cancer , vol.90 , pp. 92-103
    • Chao, K.S.1    Low, D.A.2    Perez, C.A.3
  • 38
    • 0035869712 scopus 로고    scopus 로고
    • A prospective study of salivary function sparing in patients with head-and-neck cancers receiving intensity-modulated or three-dimensional radiation therapy: Initial results
    • K.S. Chao, J.O. Deasy, K. Markman A prospective study of salivary function sparing in patients with head-and-neck cancers receiving intensity-modulated or three-dimensional radiation therapy: Initial results Int J Radiat Oncol Biol Phys 49 2001 907 916
    • (2001) Int J Radiat Oncol Biol Phys , vol.49 , pp. 907-916
    • Chao, K.S.1    Deasy, J.O.2    Markman, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.