메뉴 건너뛰기




Volumn 91, Issue 2, 1999, Pages 566-568

The esophageal detector device is unreliable when the stomach has been ventilated

Author keywords

Esophageal detector device; Gastric inflation; Intubating laryngeal mask airway; Laryngospasm

Indexed keywords

ADULT; ARTICLE; CASE REPORT; DEVICE; ENDOTRACHEAL INTUBATION; ENDOTRACHEAL TUBE; ESOPHAGUS; HUMAN; LARYNGEAL MASK; MALE; PRIORITY JOURNAL; RELIABILITY;

EID: 0032820217     PISSN: 00033022     EISSN: None     Source Type: Journal    
DOI: 10.1097/00000542-199908000-00035     Document Type: Article
Times cited : (22)

References (14)
  • 1
    • 0026667714 scopus 로고
    • The esophageal detector device: A rapid and accurate method for assessing tracheal versus esophageal intubation in a porcine model
    • Foutch RG, Magellsen MD, MacGilen JG: The esophageal detector device: A rapid and accurate method for assessing tracheal versus esophageal intubation in a porcine model. Ann Em Med 1992; 21: 1073-6
    • (1992) Ann Em Med , vol.21 , pp. 1073-1076
    • Foutch, R.G.1    Magellsen, M.D.2    Macgilen, J.G.3
  • 2
    • 0023896934 scopus 로고
    • The oesophageal detector device: Assessment of a new method to distinguish oesophageal from tracheal intubation
    • Wee MYK: The oesophageal detector device: Assessment of a new method to distinguish oesophageal from tracheal intubation. Anaesthesia 1988; 43:27-9
    • (1988) Anaesthesia , vol.43 , pp. 27-29
    • Wee, M.Y.K.1
  • 3
    • 0024550719 scopus 로고
    • The oesophageal detector device
    • Williams KN, Nunn FJ: The oesophageal detector device. Anaesthesia 1989; 44:412-14
    • (1989) Anaesthesia , vol.44 , pp. 412-414
    • Williams, K.N.1    Nunn, F.J.2
  • 4
    • 0027248049 scopus 로고
    • The oesophageal detector device. Does it work?
    • Zaleski L, Abello D, Gold MI: The oesophageal detector device. Does it work? ANESTHESIOLOGY 1993; 79:244-7
    • (1993) Anesthesiology , vol.79 , pp. 244-247
    • Zaleski, L.1    Abello, D.2    Gold, M.I.3
  • 5
    • 0027363609 scopus 로고
    • Use of the self-inflating bulb for detecting esophageal intubation after 'esophageal ventilation.'
    • Salem MR, Wafai Y, Baraka A, Taimorrazy B, Joseph NJ, Nimmagadda U: Use of the self-inflating bulb for detecting esophageal intubation after 'esophageal ventilation.' Anesth Analg 1993; 77:1227-31
    • (1993) Anesth Analg , vol.77 , pp. 1227-1231
    • Salem, M.R.1    Wafai, Y.2    Baraka, A.3    Taimorrazy, B.4    Joseph, N.J.5    Nimmagadda, U.6
  • 7
    • 0029790278 scopus 로고    scopus 로고
    • Efficacy of the self-inflating bulb in confirming tracheal intubation in the morbidly obese
    • Lang DJ, Wafai Y, Salem MR, Czinn EA, Halim AA, Baraka A: Efficacy of the self-inflating bulb in confirming tracheal intubation in the morbidly obese. ANESTHESIOLOGY 1996; 85:246-53
    • (1996) Anesthesiology , vol.85 , pp. 246-253
    • Lang, D.J.1    Wafai, Y.2    Salem, M.R.3    Czinn, E.A.4    Halim, A.A.5    Baraka, A.6
  • 8
    • 0031948445 scopus 로고    scopus 로고
    • The self-inflating bulb to detect esophageal intubation during emergency airway management
    • Kasper CL, Deem S: The self-inflating bulb to detect esophageal intubation during emergency airway management. ANESTHESIOLOGY 1998; 88:898-902
    • (1998) Anesthesiology , vol.88 , pp. 898-902
    • Kasper, C.L.1    Deem, S.2
  • 10
    • 0025690459 scopus 로고
    • Use of the oesophageal detector device in children under one year of age
    • Haynes SR, Morton NS: Use of the oesophageal detector device in children under one year of age. Anaesthesia 1990; 45:1067-9
    • (1990) Anaesthesia , vol.45 , pp. 1067-1069
    • Haynes, S.R.1    Morton, N.S.2
  • 11
    • 0030840388 scopus 로고    scopus 로고
    • The intubating laryngeal mask. I. Development of a new device for intubation of the trachea
    • Brain AIJ, Verghese C, Addy EV, Kapila A: The intubating laryngeal mask. I. Development of a new device for intubation of the trachea. Br J Anaesth 1997; 79:699-703
    • (1997) Br J Anaesth , vol.79 , pp. 699-703
    • Brain, A.I.J.1    Verghese, C.2    Addy, E.V.3    Kapila, A.4
  • 12
    • 0028871836 scopus 로고
    • Die kehlkopfmaske bei schwieriger intubation
    • Langenstein H: Die Kehlkopfmaske bei schwieriger Intubation. Anaesthesist 1995; 44:712-18
    • (1995) Anaesthesist , vol.44 , pp. 712-718
    • Langenstein, H.1
  • 13
    • 84981909759 scopus 로고
    • Oesophageal detector device
    • Mathias JA: Oesophageal detector device. Anaesthesia 1989; 44:931
    • (1989) Anaesthesia , vol.44 , pp. 931
    • Mathias, J.A.1
  • 14
    • 0028113168 scopus 로고
    • The oesophagus detector device
    • Donahue PL: The oesophagus detector device. Anaesthesia 1994; 49:863-5
    • (1994) Anaesthesia , vol.49 , pp. 863-865
    • Donahue, P.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.