메뉴 건너뛰기




Volumn 53, Issue 1, 1998, Pages 41-45

Airway auscultation. A new method of confirming tracheal intubation

Author keywords

Equipment, airway auscultation, stethoscope; Intubation, tracheal, complications

Indexed keywords

ADULT; AGED; AIRWAY; ARTICLE; AUSCULTATION; BREATHING APPARATUS; CAPNOGRAPHY; CLINICAL TRIAL; ENDOTRACHEAL INTUBATION; ESOPHAGUS INTUBATION; FEMALE; HUMAN; MAJOR CLINICAL STUDY; MALE; MORBIDITY; MORTALITY; OBSERVER VARIATION; RANDOMIZED CONTROLLED TRIAL; SINGLE BLIND PROCEDURE; STETHOSCOPE;

EID: 0031973770     PISSN: 00032409     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1365-2044.1998.00273.x     Document Type: Article
Times cited : (6)

References (17)
  • 1
    • 0025270124 scopus 로고
    • Adverse respiratory events in anaesthesiology. A closed claims analysis
    • Caplan RA, Posner KL, Ward RJ, Cheney FW. Adverse respiratory events in anaesthesiology. A closed claims analysis. Anesthesiology 1990; 72: 828-33.
    • (1990) Anesthesiology , vol.72 , pp. 828-833
    • Caplan, R.A.1    Posner, K.L.2    Ward, R.J.3    Cheney, F.W.4
  • 4
    • 0011889199 scopus 로고
    • London: BMJ Publishing Group
    • O'Flaherty D. Capnography. London: BMJ Publishing Group, 1994.
    • (1994) Capnography
    • O'Flaherty, D.1
  • 5
    • 0023896934 scopus 로고
    • The oesophageal detector device. Assessment of a new method to distinguish oesophageal from tracheal intubation
    • Wee MYK. The oesophageal detector device. Assessment of a new method to distinguish oesophageal from tracheal intubation. Anaesthesia 1988; 43: 27-9.
    • (1988) Anaesthesia , vol.43 , pp. 27-29
    • Wee, M.Y.K.1
  • 6
    • 0024077831 scopus 로고
    • The oesophageal detector device
    • Nunn JF. The oesophageal detector device. Anaesthesia 1988; 43: 804.
    • (1988) Anaesthesia , vol.43 , pp. 804
    • Nunn, J.F.1
  • 7
    • 0029589689 scopus 로고
    • SCOTI - A new device for identification of tracheal intubation
    • Murray D, Ward ME, Sear JW. SCOTI - a new device for identification of tracheal intubation. Anaesthesia 1995; 50: 1062-4.
    • (1995) Anaesthesia , vol.50 , pp. 1062-1064
    • Murray, D.1    Ward, M.E.2    Sear, J.W.3
  • 8
    • 0029083136 scopus 로고    scopus 로고
    • Detection of accidental oesophageal intubation
    • Calder I. Detection of accidental oesophageal intubation. British Journal of Anaesthesia 1996; 75: 247.
    • (1996) British Journal of Anaesthesia , vol.75 , pp. 247
    • Calder, I.1
  • 9
    • 0025690459 scopus 로고
    • Use of the oesophageal detector device in children under one year of age
    • Haynes SR, Morton NS. Use of the oesophageal detector device in children under one year of age. Anaesthesia 1990; 45: 1067-9.
    • (1990) Anaesthesia , vol.45 , pp. 1067-1069
    • Haynes, S.R.1    Morton, N.S.2
  • 10
    • 0024487091 scopus 로고
    • Detection of oesophageal intubation: The cola complication
    • Zbinden S, Schupfer G. Detection of oesophageal intubation: the cola complication. Anaesthesia 1989; 44: 81.
    • (1989) Anaesthesia , vol.44 , pp. 81
    • Zbinden, S.1    Schupfer, G.2
  • 11
    • 0027248049 scopus 로고
    • The esophageal detector device-does it work?
    • Zalski L, Abello D, Gold MI. The esophageal detector device-does it work? Anesthesiology 1993; 79: 244-7.
    • (1993) Anesthesiology , vol.79 , pp. 244-247
    • Zalski, L.1    Abello, D.2    Gold, M.I.3
  • 12
    • 0028081712 scopus 로고
    • Video analysis of two emergency tracheal intubations identifies flawed decision-making
    • Mackenzie CF, Craig GR, Parr MJ, Horst R. Video analysis of two emergency tracheal intubations identifies flawed decision-making. Anesthesiology 1994; 81: 763-71.
    • (1994) Anesthesiology , vol.81 , pp. 763-771
    • Mackenzie, C.F.1    Craig, G.R.2    Parr, M.J.3    Horst, R.4
  • 13
    • 0029790278 scopus 로고    scopus 로고
    • Efficacy of the self-inflating bulb in confirming tracheal intubation in the morbidly obese
    • Lang DJ, Wafai Y, Salem MR, Czinn EA, Halim AA, Baraka A. Efficacy of the self-inflating bulb in confirming tracheal intubation in the morbidly obese. Anesthesiology 1996; 85: 246-53.
    • (1996) Anesthesiology , vol.85 , pp. 246-253
    • Lang, D.J.1    Wafai, Y.2    Salem, M.R.3    Czinn, E.A.4    Halim, A.A.5    Baraka, A.6
  • 14
    • 0029808566 scopus 로고    scopus 로고
    • Configuration of the SCOTI device with different tracheal tubes
    • Nandwani N, Caranza R, Raphael JH. Configuration of the SCOTI device with different tracheal tubes. Anaesthesia 1996; 51: 932-4.
    • (1996) Anaesthesia , vol.51 , pp. 932-934
    • Nandwani, N.1    Caranza, R.2    Raphael, J.H.3
  • 15
    • 0028221011 scopus 로고
    • Neural network based detection of esophageal intubation
    • Leon MA, Rasanen J, Mangar D. Neural network based detection of esophageal intubation. Anesthesia and Analgesia 1994; 78: 548-53.
    • (1994) Anesthesia and Analgesia , vol.78 , pp. 548-553
    • Leon, M.A.1    Rasanen, J.2    Mangar, D.3
  • 16
    • 0031044163 scopus 로고    scopus 로고
    • SCOTI vs. Wee. An assessment of two oesophageal intubation detection devices
    • Lockey DJ, Woodward W. SCOTI vs. Wee. An assessment of two oesophageal intubation detection devices. Anaesthesia 1997; 52: 242-3.
    • (1997) Anaesthesia , vol.52 , pp. 242-243
    • Lockey, D.J.1    Woodward, W.2
  • 17
    • 0027687760 scopus 로고
    • Use of the esophageal stethoscope in pediatric transports
    • Bugnitz M, Mantz D. Use of the esophageal stethoscope in pediatric transports. Air Medical Journal 1993; 12: 429-30.
    • (1993) Air Medical Journal , vol.12 , pp. 429-430
    • Bugnitz, M.1    Mantz, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.