-
1
-
-
0014191637
-
The enzyme electrode
-
Updike SJ, Hicks GP: The enzyme electrode. Nature 1967;214:986-988.
-
(1967)
Nature
, vol.214
, pp. 986-988
-
-
Updike, S.J.1
Hicks, G.P.2
-
2
-
-
84942558425
-
Monitor and control of blood and tissue oxygen tensions
-
Clark LC: Monitor and control of blood and tissue oxygen tensions. Trans Am Soc Artif Intern Organs 1956;2:41.
-
(1956)
Trans Am Soc Artif Intern Organs
, vol.2
, pp. 41
-
-
Clark, L.C.1
-
4
-
-
0027346053
-
How the first enzyme electrode was invented
-
Clark LC: How the first enzyme electrode was invented. Biosens Bioelectron 1993;8:iii-vii.
-
(1993)
Biosens Bioelectron
, vol.8
-
-
Clark, L.C.1
-
6
-
-
0016372122
-
Progress toward a glucose sensor for the artificial pancreas
-
Bessman SP, Schultz RD: Progress toward a glucose sensor for the artificial pancreas. Adv Exp Med Biol 1974;50:189-196.
-
(1974)
Adv Exp Med Biol
, vol.50
, pp. 189-196
-
-
Bessman, S.P.1
Schultz, R.D.2
-
7
-
-
0017255492
-
Continuous extracorporeal monitoring of animal blood using the glucose electrode
-
Layne EC, Schultz RD, Thomas LJ, Slama G, Sayler DF, Bessman SP: Continuous extracorporeal monitoring of animal blood using the glucose electrode. Diabetes 1976;25: 81-89.
-
(1976)
Diabetes
, vol.25
, pp. 81-89
-
-
Layne, E.C.1
Schultz, R.D.2
Thomas, L.J.3
Slama, G.4
Sayler, D.F.5
Bessman, S.P.6
-
9
-
-
0014711450
-
Electrochemicalenzymatic analysis of blood glucose and lactate
-
Williams DL, Doig AR Jr, Korosi A: Electrochemicalenzymatic analysis of blood glucose and lactate. Anal Chem 1970;42:118-121.
-
(1970)
Anal Chem
, vol.42
, pp. 118-121
-
-
Williams, D.L.1
Doig Jr., A.R.2
Korosi, A.3
-
10
-
-
0016165501
-
An artificial endocrine pancreas
-
Albisser AM, Leibel BS, Ewart TG, Davidovac Z, Botz CK, Zingg W: An artificial endocrine pancreas. Diabetes 1974;23:389-396.
-
(1974)
Diabetes
, vol.23
, pp. 389-396
-
-
Albisser, A.M.1
Leibel, B.S.2
Ewart, T.G.3
Davidovac, Z.4
Botz, C.K.5
Zingg, W.6
-
11
-
-
0016185358
-
Clinical control of diabetes by the artificial pancreas
-
Albisser AM, Leibel BS, Ewart TG, Davidovac Z, Botz CK, Zingg W, Schipper H, Gander R: Clinical control of diabetes by the artificial pancreas. Diabetes 1974;23:397-404.
-
(1974)
Diabetes
, vol.23
, pp. 397-404
-
-
Albisser, A.M.1
Leibel, B.S.2
Ewart, T.G.3
Davidovac, Z.4
Botz, C.K.5
Zingg, W.6
Schipper, H.7
Gander, R.8
-
12
-
-
0016259390
-
The artificial beta cell-A continuous control of blood sugar by external regulation of insulin infusion (glucose controlled insulin infusion system)
-
Pfeiffer EF, Thum C, Clemens AH: The artificial beta cell-a continuous control of blood sugar by external regulation of insulin infusion (glucose controlled insulin infusion system). Horm Metab Res 1974;6:339-342.
-
(1974)
Horm Metab Res
, vol.6
, pp. 339-342
-
-
Pfeiffer, E.F.1
Thum, C.2
Clemens, A.H.3
-
13
-
-
0018192374
-
Development and evaluation of a glucose analyzer for a glucose-controlled insulin infusion system (Biostator)
-
Fogt EJ, Dodd LM, Jenning EM, Clemens AH: Development and evaluation of a glucose analyzer for a glucose controlled insulin infusion system (Biostator). Clin Chem 1978;24:1366-1372. (Pubitemid 8392017)
-
(1978)
Clinical Chemistry
, vol.24
, Issue.8
, pp. 1366-1372
-
-
Fogt, E.J.1
Dodd, L.M.2
Jenning, E.M.3
Clemens, A.H.4
-
14
-
-
6844252532
-
Blood sugar by post
-
Knight RK, Keen H: Blood sugar by post. BMJ 1961;1:1168.
-
(1961)
BMJ
, vol.1
, pp. 1168
-
-
Knight, R.K.1
Keen, H.2
-
15
-
-
0018224358
-
Jet injection of insulin during self-monitoring of blood glucose
-
Danowski TS, Sunder JH: Jet injection of insulin during selfmonitoring of blood glucose. Diabetes Care 1978;1:27-33. (Pubitemid 9211712)
-
(1978)
Diabetes Care
, vol.1
, Issue.1
, pp. 27-33
-
-
Danowski, T.S.1
Sunder, J.H.2
-
16
-
-
0017879646
-
Home monitoring of blood-glucose. Method for improving diabetic control
-
Sonksen PH, Judd SL, Lowy C: Home monitoring of blood glucose. Method for improving diabetic control. Lancet 1978;i:729-732. (Pubitemid 8303167)
-
(1978)
Lancet
, vol.1
, Issue.8067
, pp. 729-732
-
-
Sonksen, P.H.1
Judd, S.L.2
Lowy, C.3
-
17
-
-
0017833678
-
Self-monitoring of blood-glucose. Improvement of diabetic control
-
Walford S, Gale EAM, Allison SP, Tattersall RB: Selfmonitoring of blood glucose. Improvement of diabetic control. Lancet 1978;i:732-735. (Pubitemid 8303168)
-
(1978)
Lancet
, vol.1
, Issue.8067
, pp. 732-735
-
-
Walford, S.1
Gale, E.A.M.2
Allison, S.P.3
Tattersall, R.B.4
-
18
-
-
0018238448
-
Home blood glucose monitoring as an aid in diabetes management
-
Skyler JS, Lasky IA, Skyler DL, Robertson EG, Mintz DH: Home blood glucose monitoring as an aid in diabetes management. Diabetes Care 1978;1:150-157. (Pubitemid 9171567)
-
(1978)
Diabetes Care
, vol.1
, Issue.3
, pp. 150-157
-
-
Skyler, J.S.1
Lasky, I.A.2
Skyler, D.L.3
-
19
-
-
0018552435
-
Feasibility of improved blood glucose control in patients with insulin-dependent diabetes mellitus
-
Peterson CM, Jones RL, Dupuis A, Levine BS, Bernstein R, O'Shea M: Feasibility of improved blood glucose control in patients with insulin-dependent diabetes mellitus. Diabetes Care 1979;2:329-335. (Pubitemid 11190664)
-
(1979)
Diabetes Care
, vol.2
, Issue.4
, pp. 329-335
-
-
Peterson, C.M.1
Jones, R.L.2
Dupuis, A.3
-
20
-
-
0018099774
-
Pilot study of self-measurement of blood glucose using the dextrostix-eyetone system for juvenile-onset diabetes
-
Ikeda Y, Tajima N, Minami N, Ide Y, Yokoyama J, Abe M: Pilot study of self-measurement of blood glucose using the Dextrostix-Eyetone system for juvenile-onset diabetes. Diabetologia 1978;15:91-93. (Pubitemid 8397173)
-
(1978)
Diabetologia
, vol.15
, Issue.2
, pp. 91-93
-
-
Ikeda, Y.1
Tajima, N.2
Minami, N.3
-
21
-
-
0018917379
-
Feasibility of maintaining normal glucose profiles in insulin-dependent pregnant diabetic women
-
DOI 10.1016/0002-9343(80)90179-5
-
Jovanovic L, Peterson CM, Saxena HB, Dawood MY, Saudek CD: Feasibility of maintaining normal glucose profiles in insulin-dependent pregnant diabetic women. Am J Med 1980;68:105-112. (Pubitemid 10207626)
-
(1980)
American Journal of Medicine
, vol.68
, Issue.1
, pp. 105-112
-
-
Jovanovic, L.1
Peterson, C.M.2
Saxena, B.B.3
-
22
-
-
0019287196
-
Home blood-glucose monitoring. A new approach to the management of diabetes mellitus
-
Cohen M, Zimmet PZ: Home blood glucose monitoring. A new approach to the management of diabetes mellitus. Med J Aust 1980;2:713-716. (Pubitemid 11108752)
-
(1980)
Medical Journal of Australia
, vol.2
, Issue.13
, pp. 713-716
-
-
Cohen, M.1
Zimmet, P.Z.2
-
23
-
-
0018847786
-
Symposium on home blood glucose monitoring
-
Symposium on home blood glucose monitoring. Diabetes Care 1980;3:57-186.
-
(1980)
Diabetes Care
, vol.3
, pp. 57-186
-
-
-
24
-
-
0021412692
-
Ferrocene-mediated enzyme electrode for amperometric determination of glucose
-
Cass AEG, Francis DG, Hill HAO, Aston WJ, Higgins IJ, Plotkin EV, Scott LDL, Turner APF: Ferrocene-mediated enzyme electrode for the amperometric determination of glucose. Anal Chem 1984;56:667-671. (Pubitemid 14568623)
-
(1984)
Analytical Chemistry
, vol.56
, Issue.4
, pp. 667-671
-
-
Cass Anthony, E.G.1
Davis Graham2
Francis Graeme, D.3
Hill H.Allen, O.4
Aston William, J.5
Higgins I.John6
Plotkin Elliot, V.7
Scott Lesley, D.L.8
Turner Anthony, P.F.9
-
25
-
-
18044389554
-
Home blood glucose biosensors: A commercial perspective
-
DOI 10.1016/j.bios.2004.11.012, 20th Anniversary of Biosendors and Bioelectronics
-
Newman JD, Turner APF: Home blood glucose sensors: a commercial perspective. Biosensors Bioelectron 2005;20: 2435-2453. (Pubitemid 40602183)
-
(2005)
Biosensors and Bioelectronics
, vol.20
, Issue.12
, pp. 2435-2453
-
-
Newman, J.D.1
Turner, A.P.F.2
-
26
-
-
57349104419
-
Self-monitoring of blood glucose (SMBG) in insulin-and non-insulin-using adults with diabetes: Consensus recommendations for improving SMBG accuracy, utilization, and research
-
Hirsch IB, Bode BW, Childs BP, Close KL, Fisher WA, Gavin JR, Ginsberg BH, Raine CH, Verderese CA: Self-monitoring of blood glucose (SMBG) in insulin-and non-insulin-using adults with diabetes: consensus recommendations for improving SMBG accuracy, utilization, and research. Diabetes Technol Ther 2008;10:419-439.
-
(2008)
Diabetes Technol Ther
, vol.10
, pp. 419-439
-
-
Hirsch, I.B.1
Bode, B.W.2
Childs, B.P.3
Close, K.L.4
Fisher, W.A.5
Gavin, J.R.6
Ginsberg, B.H.7
Raine, C.H.8
Verderese, C.A.9
-
27
-
-
0020134836
-
Symposium on potentially implantable glucose sensors
-
Symposium on potentially implantable glucose sensors. Diabetes Care 1982;5:147-283.
-
(1982)
Diabetes Care
, vol.5
, pp. 147-283
-
-
-
28
-
-
0020134817
-
Implanted electroenzymatic glucose sensors
-
Clark LC Jr, Duggan CA: Implanted electroenzymatic glucose sensors. Diabetes Care 1982;5:174-180.
-
(1982)
Diabetes Care
, vol.5
, pp. 174-180
-
-
Clark Jr., L.C.1
Duggan, C.A.2
-
29
-
-
0020058620
-
Implanting the glucose enzyme electrode: Problems, progress, and alternative solutions
-
Updike SJ, Shults M, Ekman B: Implanting the glucose enzyme electrode: problems, progress, and alternative solutions. Diabetes Care 1982;5:207-212. (Pubitemid 12117167)
-
(1982)
Diabetes Care
, vol.5
, Issue.3
, pp. 207-212
-
-
Updike, S.J.1
Shults, M.2
Ekman, B.3
-
30
-
-
0020038706
-
Measurement of glucose concentration in the presence of coreactants with a platinum electrode
-
Lerner H, Soeldner JS, Colton CK, Giner J: Measurement of glucose concentration in the presence of coreactants with a platinum electrode. Diabetes Care 1982;5:229-237. (Pubitemid 12117172)
-
(1982)
Diabetes Care
, vol.5
, Issue.3
, pp. 229-237
-
-
Lerner, H.1
Soeldner, J.S.2
Colton, C.K.3
Giner, J.4
-
31
-
-
0020072276
-
Glucose sensor characteristics for miniaturized portable closed-loop insulin delivery: A step toward implantation
-
Oberhardt BJ, Fogt EJ, Clemens AH: Glucose sensor characteristics for miniaturized portable closed-loop insulin delivery: a step toward implantation. Diabetes Care 1982; 5:213-217. (Pubitemid 12117168)
-
(1982)
Diabetes Care
, vol.5
, Issue.3
, pp. 213-217
-
-
Oberhardt, B.J.1
Fogt, E.J.2
Clemens, A.H.3
-
32
-
-
0020037171
-
Progress toward a potentially implantable, enzyme-based glucose sensor
-
Gough DA, Leypoldt JK, Armour JC: Progress toward a potentially implantable, enzyme-based glucose sensor. Diabetes Care 1982;5:190-198.
-
(1982)
Diabetes Care
, vol.5
, pp. 190-198
-
-
Gough, D.A.1
Leypoldt, J.K.2
Armour, J.C.3
-
33
-
-
0020297949
-
Membrane combination for implantable glucose sensors. Measurements in undiluted biological fluids
-
Fischer U, Abel P: A membrane combination for implantable glucose sensors. Measurements in undiluted biological fluids. Trans Am Soc Artif Intern Organs 1982;28:245-248. (Pubitemid 13496573)
-
(1982)
Transactions - American Society for Artificial Internal Organs
, vol.28
, pp. 245-248
-
-
Fischer, U.1
Abel, P.2
-
34
-
-
0020402631
-
Wearable artificial endocrine pancreas with needle-type glucose sensor
-
Shichiri M, Kawamori R, Yamasaki Y, Hakui N, Abe H: Wearable artificial endocrine pancreas with needle-type glucose sensor. Lancet 1982;2:1129-1131. (Pubitemid 13232061)
-
(1982)
Lancet
, vol.2
, Issue.8308
, pp. 1129-1131
-
-
Shichiri, M.1
Yamasaki, Y.2
Abe, H.3
-
35
-
-
0024235567
-
A potentially implantable enzyme electrode for amperometric measurement of glucose
-
Kerner W, Zier H, Steinbach G, Brückel J, Pfeiffer EF, Weiss T, Cammann K, Planck H: A potentially implantable enzyme electrode for amperometric measurement of glucose. Horm Metab Res Suppl 1988;20:8-13. (Pubitemid 19058914)
-
(1988)
Hormone and Metabolic Research
, vol.20
, Issue.SUPPL.
, pp. 8-13
-
-
Kerner, W.1
Zier, H.2
Steinbach, G.3
Bruckel, J.4
Pfeiffer, E.F.5
Weiss, T.6
Cammann, K.7
Planck, H.8
-
36
-
-
0024541965
-
In vivo molecular sensing in diabetes mellitus: an implantable glucose sensor with direct electron transfer
-
DOI 10.1007/BF00265097
-
Pickup JC, Shaw GS, Claremont DJ: In vivo molecular sensing in diabetes mellitus: an implantable glucose sensor with direct electron transfer. Diabetologia 1989;32:213-217. (Pubitemid 19117104)
-
(1989)
Diabetologia
, vol.32
, Issue.3
, pp. 213-217
-
-
Pickup, J.C.1
Shaw, G.W.2
Claremont, D.J.3
-
37
-
-
0024817210
-
Pulsed amperometric detection of glucose in biological fluids at a surface-modified gold electrode
-
DOI 10.1021/ac00197a022
-
Bindra DS, Wilson GS: Pulsed amperometric detection of glucose in biological fluids at a surface-modified gold electrode. Anal Chem 1989;61:2566-2570. (Pubitemid 20013878)
-
(1989)
Analytical Chemistry
, vol.61
, Issue.22
, pp. 2566-2570
-
-
Bindar, D.S.1
Wilson, G.S.2
-
38
-
-
0025689061
-
Application of chronic intravascular blood glucose sensor in dogs
-
Armour JC, Lucisano JY, McKean BD, Gough DA: Application of chronic intravascular blood glucose sensor in dogs. Diabetes 1990;39:1519-1526.
-
(1990)
Diabetes
, vol.39
, pp. 1519-1526
-
-
Armour, J.C.1
Lucisano, J.Y.2
McKean, B.D.3
Gough, D.A.4
-
39
-
-
0033764602
-
Immobilized glucose oxidase in implantable glucose sensor technology
-
Gough DA, Bremer T: Immobilized glucose oxidase in implantable glucose sensor technology. Diabetes Technol Ther 2000;2:377-380.
-
(2000)
Diabetes Technol Ther
, vol.2
, pp. 377-380
-
-
Gough, D.A.1
Bremer, T.2
-
40
-
-
0026756276
-
Progress toward the development of an implantable sensor for glucose
-
Wilson GS, Zhang Y, Reach G, Moatti-Sirat D, Poitout V, Thévenot DR, Lemonnier F, Klein JC: Progress toward the development of an implantable sensor for glucose. Clin Chem 1992;38:1613-1617.
-
(1992)
Clin Chem
, vol.38
, pp. 1613-1617
-
-
Wilson, G.S.1
Zhang, Y.2
Reach, G.3
Moatti-Sirat, D.4
Poitout, V.5
Thévenot, D.R.6
Lemonnier, F.7
Klein, J.C.8
-
41
-
-
0032836714
-
Subcutaneous glucose predicts plasma glucose independent of insulin: Implications for continuous monitoring
-
Rebrin K, Steil GM, Van Antwerp WP, Mastrototaro JJ: Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring. Am J Physiol 1992;277:E561-E571.
-
(1992)
Am J Physiol
, vol.277
-
-
Rebrin, K.1
Steil, G.M.2
Van Antwerp, W.P.3
Mastrototaro, J.J.4
-
42
-
-
0027102347
-
In vivo evaluation of an electroenzymatic glucose sensor implanted in subcutaneous tissue
-
DOI 10.1016/0956-5663(92)85053-D
-
Johnson KW, Mastrototaro JJ, Howey DC, Brunelle RL, Burden-Brady PL, Bryan NA, Andrew CC, Rowe HM, Allen DJ, Noffke BW, McMaham WC, Morff RJ, Lipson D, Nevin RS: In vivo evaluation of an electroenzymatic glucose sensor implanted in subcutaneous tissue. Biosens Bioelectron 1992;7:709-714. (Pubitemid 23038816)
-
(1992)
Biosensors and Bioelectronics
, vol.7
, Issue.10
, pp. 709-714
-
-
Johnson, K.W.1
Mastrototaro, J.J.2
Howey, D.C.3
Brunelle, R.L.4
Burden-Brady, P.L.5
Bryan, N.A.6
Andrew, C.C.7
Rowe, H.M.8
Allen, D.J.9
Noffke, B.W.10
McMahan, W.C.11
Morff, R.J.12
Lipson, D.13
Nevin, R.S.14
-
43
-
-
0027474090
-
On line continuous monitoring of subcutaneous tissue glucose is feasible by combining portable glucosensor with microdialysis
-
Pfeiffer EF, Meyerhoff C, Bischof F, Keck FS, Kerner W: One line continuous monitoring of subcutaneous tissue glucose is feasible by combining portable glucosensor with microdialysis. Horm Metab Res 1993;25:121-124. (Pubitemid 23076199)
-
(1993)
Hormone and Metabolic Research
, vol.25
, Issue.2
, pp. 121-124
-
-
Pfeiffer, E.F.1
Meyerhoff, C.2
Bischof, F.3
Keck, F.S.4
Kerner, W.5
-
44
-
-
0029075404
-
Continuous in vivo monitoring in diabetes: The subcutaneous glucose concentration
-
Fisher U: Continuous in vivo monitoring in diabetes: the subcutaneous glucose concentration. Acta Anaesthesiol Scand 1995;39(Suppl 104):21-29.
-
(1995)
Acta Anaesthesiol Scand
, vol.39
, Issue.SUPPL. 104
, pp. 21-29
-
-
Fisher, U.1
-
45
-
-
0028807108
-
Development of the implantable glucose sensor. What are the prospects and why is it taking so long?
-
Gough DA, Armour JC: Development of the implantable glucose sensor. What are the prospects and why is it taking so long? Diabetes 1995;44:1005-1009.
-
(1995)
Diabetes
, vol.44
, pp. 1005-1009
-
-
Gough, D.A.1
Armour, J.C.2
-
46
-
-
0030293604
-
Use of a subcutaneous glucose sensor to detect decreases in glucose concentration prior to observation in blood
-
Thomé-Duret V, Reach G, Gangnerau MN, Lemonnier F, Klein JC, Zhang Y, Wilson GS: Use of a subcutaneous glucose sensor to detect decreases in glucose concentration prior to observation in blood. Anal Chem 1996;68:3822-3826.
-
(1996)
Anal Chem
, vol.68
, pp. 3822-3826
-
-
Thomé-Duret, V.1
Reach, G.2
Gangnerau, M.N.3
Lemonnier, F.4
Klein, J.C.5
Zhang, Y.6
Wilson, G.S.7
-
47
-
-
0034004142
-
Interstitial glucose concentration and glycemia: Implications for continuous subcutaneous glucose monitoring
-
Aussedat B, Dupire-Angel M, Gifford R, Klein JC, Wilson GS, Reach G: Interstitial glucose concentration and glycemia: implications for continuous subcutaneous glucose monitoring. Am J Physiol 2000;278:E716-E728. (Pubitemid 30215184)
-
(2000)
American Journal of Physiology - Endocrinology and Metabolism
, vol.278
, Issue.4
-
-
Aussedat, B.1
Dupire-Angel, M.2
Gifford, R.3
Klein, J.C.4
Wilson, G.S.5
Reach, G.6
-
48
-
-
0036162977
-
A new amperometric glucose microsensor: In vitro and short-term in vivo evaluation
-
DOI 10.1016/S0956-5663(01)00268-8, PII S0956566301002688
-
Ward WK, Jansen LB, Anderson E, Reach G, Klein JC, Wilson GS: A new amperometric glucose microsensor: in vitro and short-term in vivo evaluation. Biosens Bioelectron 2002;17:181-189. (Pubitemid 34142598)
-
(2002)
Biosensors and Bioelectronics
, vol.17
, Issue.3
, pp. 181-189
-
-
Ward W.Kenneth1
Jansen, L.B.2
Anderson, E.3
Reach, G.4
Klein, J.-C.5
Wilson, G.S.6
-
50
-
-
0034491295
-
The MiniMed continuous glucose monitoring System
-
Mastrototaro JJ: The Mini Med continuous glucose monitoring system. Diabetes Technol Ther 2000;2(Suppl 1):S13-S18. (Pubitemid 32107467)
-
(2000)
Diabetes Technology and Therapeutics
, vol.2
, Issue.SUPPL. 1
-
-
Mastrototaro, J.J.1
-
51
-
-
0032754795
-
Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin: A pilot study
-
Bode BW, Gross TM, Thornton KR, Mastrototaro JJ: Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin: a pilot study. Diabetes Res Clin Pract 1999;46:183-190.
-
(1999)
Diabetes Res Clin Pract
, vol.46
, pp. 183-190
-
-
Bode, B.W.1
Gross, T.M.2
Thornton, K.R.3
Mastrototaro, J.J.4
-
52
-
-
0034117324
-
Performance evaluation of the MiniMed continuous glucose monitoring system during patient home use
-
Gross TM, Bode BW, Einhorn D, Kayne DM, Reed JH, White NH, Mastrototaro JJ: Performance evaluation of the Mini Med continuous glucose monitoring system during patient home use. Diabetes Technol Ther 2000;2:49-56. (Pubitemid 30256421)
-
(2000)
Diabetes Technology and Therapeutics
, vol.2
, Issue.1
, pp. 49-56
-
-
Gross, T.M.1
Bode, B.W.2
Einhorn, D.3
Kayne, D.M.4
Reed, J.H.5
White, N.H.6
Mastrototaro, J.J.7
-
53
-
-
84878080377
-
Advances in continuous glucose monitoring in diabetes mellitus
-
Skyler JS, ed.: Advances in continuous glucose monitoring in diabetes mellitus. Diabetes Technol Ther 2000;2(Suppl 1): S1-S97.
-
(2000)
Diabetes Technol Ther
, vol.2
, Issue.SUPPL. 1
-
-
Skyler, J.S.1
-
54
-
-
0242268979
-
The accuracy of the CGMS in children with type 1 diabetes: Results of the diabetes research in children network (direc net) accuracy study
-
Diabetes Research in Children Network (Direc Net) Study Group
-
Diabetes Research in Children Network (Direc Net) Study Group: The accuracy of the CGMS in children with type 1 diabetes: results of the Diabetes Research in Children Network (Direc Net) Accuracy Study. Diabetes Technol Ther 2003;5:781-789.
-
(2003)
Diabetes Technol Ther
, vol.5
, pp. 781-789
-
-
-
55
-
-
50049110650
-
The accuracy of the guardian RT continuous glucose monitor in children with type 1 diabetes
-
Diabetes Research in Children Network (Direc Net) Study Group
-
Diabetes Research in Children Network (Direc Net) Study Group: The accuracy of the Guardian RT continuous glucose monitor in children with type 1 diabetes. Diabetes Technol Ther 2008;10:266-272.
-
(2008)
Diabetes Technol Ther
, vol.10
, pp. 266-272
-
-
-
56
-
-
50049108982
-
The accuracy and efficacy of real-time continuous glucose monitoring sensor in patients with type 1 diabetes
-
STAR 1 Clinical Trial Investigators
-
Mastrototaro J, Shin J, Marcus A, Sulur G; STAR 1 Clinical Trial Investigators: The accuracy and efficacy of real-time continuous glucose monitoring sensor in patients with type 1 diabetes. Diabetes Technol Ther 2008;10:385-390.
-
(2008)
Diabetes Technol Ther
, vol.10
, pp. 385-390
-
-
Mastrototaro, J.1
Shin, J.2
Marcus, A.3
Sulur, G.4
-
57
-
-
0028823945
-
Measurement of glucose in diabetic subjects using noninvasive transdermal extraction
-
Tamada JA, Bohannon NJV, Potts RO: Measurement of glucose in diabetic subjects using noninvasive transdermal extraction. Nat Med 1995;1:1198-1201.
-
(1995)
Nat Med
, vol.1
, pp. 1198-1201
-
-
Tamada, J.A.1
Bohannon, N.J.V.2
Potts, R.O.3
-
58
-
-
0000994919
-
Design of a biosensor for continual, transdermal glucose monitoring
-
Tierney MJ, Jayalakshmi Y, Parris NA, Reidy MP, Uhegbu C, Vijayakumar P: Design of a biosensor for continual, transdermal glucose monitoring. Clin Chem 1999;45:1681-1682.
-
(1999)
Clin Chem
, vol.45
, pp. 1681-1682
-
-
Tierney, M.J.1
Jayalakshmi, Y.2
Parris, N.A.3
Reidy, M.P.4
Uhegbu, C.5
Vijayakumar, P.6
-
59
-
-
0033579205
-
Noninvasive glucose monitoring: Comprehensive clinical results. Cygnus Research Team
-
Tamada JA, Garg S, Jovanovic L, Pitzer KR, Fermi S, Potts RO: Noninvasive glucose monitoring: comprehensive clinical results. Cygnus Research Team. JAMA 1999;282:1839-1844.
-
(1999)
JAMA
, vol.282
, pp. 1839-1844
-
-
Tamada, J.A.1
Garg, S.2
Jovanovic, L.3
Pitzer, K.R.4
Fermi, S.5
Potts, R.O.6
-
60
-
-
0032882086
-
Correlation of fingerstick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with type 1 diabetes
-
DOI 10.2337/diacare.22.10.1708
-
Garg SK, Potts RO, Ackerman NR, Fermi S, Tamada JA, Chase PH: Correlation of fingerstick blood glucose measurements with Gluco Watch Biographer glucose results in young subjects with type 1 diabetes. Diabetes Care 1999; 22:1708-1714. (Pubitemid 29458398)
-
(1999)
Diabetes Care
, vol.22
, Issue.10
, pp. 1708-1714
-
-
Garg, S.K.1
Potts, R.O.2
Ackerman, N.R.3
Fermi, S.J.4
Tamada, J.A.5
Chase, H.P.6
-
61
-
-
0242300688
-
The accuracy of the gluco watch G2 biographer in children with type 1 diabetes: Results of the diabetes research in children network (direc net) accuracy study
-
Diabetes Research in Children Network (Direc Net) Study Group
-
Diabetes Research in Children Network (Direc Net) Study Group: The accuracy of the Gluco Watch G2 Biographer in children with type 1 diabetes: results of the Diabetes Research in Children Network (Direc Net) Accuracy Study. Diabetes Technol Ther 2003;5:791-800.
-
(2003)
Diabetes Technol Ther
, vol.5
, pp. 791-800
-
-
-
62
-
-
0024446904
-
Microdialysis of subcutaneous adipose tissue in vivo for continuous glucose monitoring in man
-
Bolinder J, Hangstrom E, Ungerstedt U, Arner P: Microdialysis of subcutaneous adipose tissue in vivo for continuous glucose monitoring in man. Scand J Clin Lab Invest 1989;49:465-474. (Pubitemid 19218908)
-
(1989)
Scandinavian Journal of Clinical and Laboratory Investigation
, vol.49
, Issue.5
, pp. 465-474
-
-
Bolinder, J.1
Hagstrom, E.2
Ungerstedt, U.3
Arner, P.4
-
63
-
-
0242586071
-
A microdialysis technique for continuous subcutaneous glucose monitoring in diabetic patients (part 1)
-
DOI 10.1016/S0956-5663(02)00216-6, PII S0956566302002166
-
Poscia A, Mascini M, Moscone D, Luzzana M, Caramenti G, Cremonesi P, Valgimigli F, Bongiovanni C, Varalli M: A microdialysis technique for continuous subcutaneous glucose monitoring in diabetic patients (part 1). Biosens Bioelectron 2003;18:891-898. (Pubitemid 36507144)
-
(2003)
Biosensors and Bioelectronics
, vol.18
, Issue.7
, pp. 891-898
-
-
Poscia, A.1
Mascini, M.2
Moscone, D.3
Luzzana, M.4
Caramenti, G.5
Cremonesi, P.6
Valgimigli, F.7
Bongiovanni, C.8
Varalli, M.9
-
64
-
-
0242418182
-
A microdialysis technique for continuous subcutaneous glucose monitoring in diabetic patients (part 2)
-
DOI 10.1016/S0956-5663(02)00215-4, PII S0956566302002154
-
Varalli M, Marelli G, Maran A, Bistoni S, Luzzana M, Cremonesi P, Caramenti G, Valgimigli F, Poscia A: A microdialysis technique for continuous subcutaneous glucose monitoring in diabetic patients (part 2). Biosens Bioelectron 2003;18:899-905. (Pubitemid 36507145)
-
(2003)
Biosensors and Bioelectronics
, vol.18
, Issue.7
, pp. 899-905
-
-
Varalli, M.1
Marelli, G.2
Maran, A.3
Bistoni, S.4
Luzzana, M.5
Cremonesi, P.6
Caramenti, G.7
Valgimigli, F.8
Poscia, A.9
-
65
-
-
3543006509
-
Microdialysis of glucose in subcutaneous adipose tissue up to 3 weeks in healthy volunteers
-
Wientjes KJ, Vonk P, Vonk-Van Klei Y, Schoonen AJM, Kossen NW: Microdialysis of glucose in subcutaneous adipose tissue up to 3 weeks in healthy volunteers. Diabetes Care 1998;21:1481-1488. (Pubitemid 28405200)
-
(1998)
Diabetes Care
, vol.21
, Issue.9
, pp. 1481-1488
-
-
Wientjes, K.J.1
Vonk, P.2
Vonk-Van Klei, Y.3
Schoonen, A.J.M.4
Kossen, N.W.5
-
66
-
-
0036481429
-
Continuous subcutaneous glucose monitoring in diabetic patients: A multicenter analysis
-
DOI 10.2337/diacare.25.2.347
-
Maran A, Crepaldi C, Tiengo A, Grassi G, Vitali E, Pagano G, Bistoni S, Calabrese G, Santeusanio F, Leonetti F, Ribaudo M, Di Mario U, Annuzzi G, Genovese S, Riccardi G, Previti M, Cucinotta D, Giorgino F, Bellomo A, Giorgino R, Poscia A, Varalli M: Continuous subcutaneous glucose monitoring in diabetic patients: a multicenter analysis. Diabetes Care 2002;25:347-352. (Pubitemid 41079634)
-
(2002)
Diabetes Care
, vol.25
, Issue.2
, pp. 347-352
-
-
Maran, A.1
Crepaldi, C.2
Tiengo, A.3
Grassi, G.4
Vitali, E.5
Pagano, G.6
Bistoni, S.7
Calabrese, G.8
Santeusanio, F.9
Leonetti, F.10
Ribaudo, M.11
Mario, U.D.I.12
Annuzzi, G.13
Genovese, S.14
Riccardi, G.15
Previti, M.16
Cucinotta, D.17
Giorgino, F.18
Bellomo, A.19
Giorgino, R.20
Poscia, A.21
Varalli, M.22
more..
-
67
-
-
33845616782
-
Microdialysis-based 48-hour continuous glucose monitoring with GlucoDay: Clinical performance and patients' acceptance
-
DOI 10.1089/dia.2006.8.570
-
Kubiak T, Wörle B, Kuhr B, Nied I, Gläsner G, Hermanns N, Kulzer B, Haak T: Microdialysis-based 48-hour continuous glucose monitoring with Gluco Day: clinical performance and patients' acceptance. Diabetes Technol Ther 2006;8:570-575. (Pubitemid 44946881)
-
(2006)
Diabetes Technology and Therapeutics
, vol.8
, Issue.5
, pp. 570-575
-
-
Kubiak, T.1
Worle, B.2
Kuhr, B.3
Nied, I.4
Glasner, G.5
Hermanns, N.6
Kulzer, B.7
Haak, T.8
-
68
-
-
33748783797
-
Accuracy of continuous subcutaneous glucose monitoring with the GlucoDay® in type 1 diabetic patients treated by subcutaneous insulin infusion during exercise of low versus high intensity
-
DOI 10.1016/S1262-3636(07)70285-9
-
Fayollea C, Bruna JF, Bringerb J, Merciera J, Renard E: Accuracy of continuous subcutaneous glucose monitoring with the Gluco Day® in type 1 diabetic patients treated by subcutaneous insulin infusion during exercise of low versus high intensity. Diabetes Metab 2006;32:313-320. (Pubitemid 44410144)
-
(2006)
Diabetes and Metabolism
, vol.32
, Issue.4
, pp. 313-320
-
-
Fayolle, C.1
Brun, J.F.2
Bringer, J.3
Mercier, J.4
Renard, E.5
-
69
-
-
0035461856
-
Subcutaneous continuous glucose monitoring: Feasibility of a new microdialysis-based glucose sensor system
-
Jungheim K, Wientjes KJ, Heinemann L, Lodwig V, Koschinsky T, Schoonen AJ: Subcutaneous continuous glucose monitoring: feasibility of a new microdialysis-based glucose sensor system. Diabetes Care 2001;24:1696-1697.
-
(2001)
Diabetes Care
, vol.24
, pp. 1696-1697
-
-
Jungheim, K.1
Wientjes, K.J.2
Heinemann, L.3
Lodwig, V.4
Koschinsky, T.5
Schoonen, A.J.6
-
70
-
-
0041517696
-
Effects of microdialysis catheter insertion into the subcutaneous adipose tissue assessed by the SCGM1 system
-
DOI 10.1089/152091503322250631
-
Wientjes KJ, Grob U, Hattemer A, Hoogenberg K, Jungheim K, Kapitza C, Schoonen AJ; Glucose Monitoring Study Group: Effects of microdialysis catheter insertion into the subcutaneous adipose tissue assessed by the SCGM1 system. Diabetes Technol Ther 2003;5:615-620. (Pubitemid 36999274)
-
(2003)
Diabetes Technology and Therapeutics
, vol.5
, Issue.4
, pp. 615-620
-
-
Wientjes, K.J.C.1
Grob, U.2
Hattemer, A.3
Hoogenberg, K.4
Jungheim, K.5
Kapitza, C.6
Schoonen, A.J.M.7
-
71
-
-
50149114734
-
Microdialysis glucose sensor system compared with needle type glucose sensor in vivo during OGTT and physical exercise
-
New York: IEEE, 2006, doi:10.1109=ICSENS.2007.355793
-
Moon BU, Wientjes KJC, Schoonen AJM: Microdialysis glucose sensor system compared with needle type glucose sensor in vivo during OGTT and physical exercise. In: 5th IEEE Conference on Sensors, 2006. New York: IEEE, 2006, doi:10.1109=ICSENS.2007.355793.
-
(2006)
5th IEEE Conference on Sensors
-
-
Moon, B.U.1
Wientjes, K.J.C.2
Schoonen, A.J.M.3
-
72
-
-
0028106630
-
Evaluation of a subcutaneous glucose sensor out to 3 months in a dog model
-
Gilligan BJ, Shults MC, Rhodes RK, Updike SJ: Evaluation of a subcutaneous glucose sensor out to 3 months in a dog model. Diabetes Care 1994;17:882-887. (Pubitemid 24235512)
-
(1994)
Diabetes Care
, vol.17
, Issue.8
, pp. 882-887
-
-
Gilligan, B.J.1
Shults, M.C.2
Rhodes, R.K.3
Updike, S.J.4
-
73
-
-
0033970025
-
A subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration
-
Updike SJ, Shults MC, Gilligan BJ, Rhodes RK: A subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration. Diabetes Care 2000;23: 208-214. (Pubitemid 30071026)
-
(2000)
Diabetes Care
, vol.23
, Issue.2
, pp. 208-214
-
-
Updike, S.J.1
Shults, M.C.2
Gilligan, B.J.3
Rhodes, R.K.4
-
74
-
-
3042688474
-
Feasibility of continuous long-term glucose monitoring from a subcutaneous glucose sensor in humans
-
DOI 10.1089/152091504774198089
-
Gilligan BC, Shults M, Rhodes RK, Jacobs PG, Brauker JH, Pintar TJ, Updike SJ: Feasibility of continuous long-term glucose monitoring from a subcutaneous glucose sensor in humans. Diabetes Technol Ther 2004;6:378-386. (Pubitemid 38821624)
-
(2004)
Diabetes Technology and Therapeutics
, vol.6
, Issue.3
, pp. 378-386
-
-
Gilligan, B.J.1
Shults, M.C.2
Rhodes, R.K.3
Jacobs, P.G.4
Brauker, J.H.5
Pintar, T.J.6
Updike, S.J.7
-
75
-
-
1442324399
-
Improved glucose excursions using an implantable real-time continuous glucose sensor in adults with type 1 diabetes
-
DOI 10.2337/diacare.27.3.734
-
Garg SK, Schwartz S, Edelman SV: Improved glucose excursions using an implantable real-time continuous glucose sensor in adults with type 1 diabetes. Diabetes Care 2004;27:734-738. (Pubitemid 38280542)
-
(2004)
Diabetes Care
, vol.27
, Issue.3
, pp. 734-738
-
-
Garg, S.K.1
Schwartz, S.2
Edelman, S.V.3
-
76
-
-
64749099221
-
Feasibility of 10-day use of a continuous glucose-monitoring system in adults with type 1 diabetes
-
Garg SK, Voelmle MK, Gottlieb P: Feasibility of 10-day use of a continuous glucose-monitoring system in adults with type 1 diabetes. Diabetes Care 2009;32:436-438.
-
(2009)
Diabetes Care
, vol.32
, pp. 436-438
-
-
Garg, S.K.1
Voelmle, M.K.2
Gottlieb, P.3
-
77
-
-
33644875792
-
Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: A randomized controlled trial
-
Garg S, Zisser H, Schwartz S, Bailey T, Kaplan R, Ellis S, Jovanovic L: Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: a randomized controlled trial. Diabetes Care 2006;29:44-50. (Pubitemid 44033429)
-
(2006)
Diabetes Care
, vol.29
, Issue.1
, pp. 44-50
-
-
Garg, S.1
Zisser, H.2
Schwartz, S.3
Bailey, T.4
Kaplan, R.5
Ellis, S.6
Jovanovic, L.7
-
78
-
-
33845475479
-
1c values: Safety, accuracy, and improvements in glucose profiles obtained using a 7-day continuous glucose sensor
-
DOI 10.2337/dc06-1361
-
Garg S, Jovanovic L: Relationship of fasting and hourly blood glucose levels to HbA1c values: safety, accuracy, and improvements in glucose profiles obtained using a 7-day continuous glucose sensor. Diabetes Care 2006;29:2644-2649. (Pubitemid 44912192)
-
(2006)
Diabetes Care
, vol.29
, Issue.12
, pp. 2644-2649
-
-
Garg, S.1
Jovanovic, L.2
-
79
-
-
37149049051
-
Continuous home monitoring of glucose: Improved glycemic control with real-life use of continuous glucose sensors in adult subjects with type 1 diabetes
-
DOI 10.2337/dc07-1436
-
Garg SK, Kelly WC, Voelmle MK, Ritchie PJ, Gottlieb PA, McFann KK, Ellis SL: Continuous home monitoring of glucose: improved glycemic control with real-life use of continuous glucose sensors in adult subjects with type 1 diabetes. Diabetes Care 2007;30:3023-3025. (Pubitemid 350255236)
-
(2007)
Diabetes Care
, vol.30
, Issue.12
, pp. 3023-3025
-
-
Garg, S.K.1
Kelly, W.C.2
Voelmle, M.K.3
Ritchie, P.J.4
Gottlieb, P.A.5
McFann, K.K.6
Ellis, S.L.7
-
80
-
-
34250776500
-
Reduction in hemoglobin A1c with real-time continuous glucose monitoring: Results from a 12-week observational study
-
DOI 10.1089/dia.2007.0205
-
Bailey TS, Zisser HC, Garg SK: Reduction in hemoglobin A1C with real-time continuous glucose monitoring: results from a 12-week observational study. Diabetes Technol Ther 2007;9:203-210. (Pubitemid 46959785)
-
(2007)
Diabetes Technology and Therapeutics
, vol.9
, Issue.3
, pp. 203-210
-
-
Bailey, T.S.1
Zisser, H.C.2
Garg, S.K.3
-
81
-
-
0029287405
-
Design and optimization of a selective subcutaneously implantable glucose electrode based on "wired" glucose oxidase
-
Csoregi E, Schmidtke DW, Heller A: Design and optimization of a selective subcutaneously implantable glucose electrode based on "wired" glucose oxidase. Anal Chem 1995;67:1240-1244.
-
(1995)
Anal Chem
, vol.67
, pp. 1240-1244
-
-
Csoregi, E.1
Schmidtke, D.W.2
Heller, A.3
-
82
-
-
0242363717
-
A Continuous Glucose Sensor Based on Wired Enzyme Technology - Results from a 3-Day Trial in Patients with Type 1 Diabetes
-
DOI 10.1089/152091503322526978
-
Feldman B, Brazg R, Schwartz S, Weinstein R: A continuous glucose sensor based on Wired Enzyme technology-results from a 3-day trial in patients with type 1 diabetes. Diabetes Technol Ther 2003;5:769-779. (Pubitemid 37339539)
-
(2003)
Diabetes Technology and Therapeutics
, vol.5
, Issue.5
, pp. 769-779
-
-
Feldman, B.1
Brazg, R.2
Schwartz, S.3
Weinstein, R.4
-
83
-
-
70349240853
-
The chemistry of commercial continuous glucose monitors
-
S-xx-S-xx
-
McGarraugh G: The chemistry of commercial continuous glucose monitors. Diabetes Technol Ther 2009;11(Suppl 1): S-xx-S-xx.
-
(2009)
Diabetes Technol Ther
, vol.11
, Issue.SUPPL. 1
-
-
McGarraugh, G.1
-
84
-
-
33846111973
-
The accuracy of the free style navigator™ continuous glucose monitoring system in children with type 1 diabetes
-
Diabetes Research in Children Network (Direc Net) Study Group
-
Diabetes Research in Children Network (Direc Net) Study Group: The Accuracy of the Free Style Navigator™ Continuous Glucose Monitoring System in Children with Type 1 Diabetes. Diabetes Care 2007;30:59-64.
-
(2007)
Diabetes Care
, vol.30
, pp. 59-64
-
-
-
85
-
-
44449178472
-
Free Style Navigator™ continuous glucose monitoring system use in children with type 1 diabetes using glargine-based multiple daily dose regimens: Results of a pilot trial
-
Diabetes Research in Children Network (Direc Net) Study Group
-
Diabetes Research in Children Network (Direc Net) Study Group: Free Style Navigator™ continuous glucose monitoring system use in children with type 1 diabetes using glargine-based multiple daily dose regimens: results of a pilot trial. Diabetes Care 2008;31:525-527.
-
(2008)
Diabetes Care
, vol.31
, pp. 525-527
-
-
-
86
-
-
42449113362
-
Use of the Direc Net Applied Treatment Algorithm (DATA) for diabetes management with a real-time continuous glucose monitor (the Freestyle Navigator)
-
Diabetes Research in Children Network (Direc Net) Study Group
-
Diabetes Research in Children Network (Direc Net) Study Group: Use of the Direc Net Applied Treatment Algorithm (DATA) for diabetes management with a real-time continuous glucose monitor (the Freestyle Navigator). Pediatr Diabetes 2008;9:142-147.
-
(2008)
Pediatr Diabetes
, vol.9
, pp. 142-147
-
-
-
87
-
-
58449116859
-
Comparison of accuracy and safety of the SEVEN and the Navigator continuous glucose monitoring systems
-
Garg SK, Smith J, Beatson C, Lopez-Baca B, Voelmle M, Gottlieb PA: Comparison of accuracy and safety of the SEVEN and the Navigator continuous glucose monitoring systems. Diabetes Technol Ther 2009;11:65-72.
-
(2009)
Diabetes Technol Ther
, vol.11
, pp. 65-72
-
-
Garg, S.K.1
Smith, J.2
Beatson, C.3
Lopez-Baca, B.4
Voelmle, M.5
Gottlieb, P.A.6
-
88
-
-
33845483509
-
Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring
-
DOI 10.2337/dc06-1134
-
Deiss D, Bolinder J, Riveline J-P, Battelino T, Bosi E, Tubiana-Rufi N, Kerr D, Phillip M: Improved glycemic control in poorly controlled patients with type 1 diabetes using realtime continuous glucose monitoring. Diabetes Care 2006; 29:2730-2732. (Pubitemid 44912209)
-
(2006)
Diabetes Care
, vol.29
, Issue.12
, pp. 2730-2732
-
-
Deiss, D.1
Bolinder, J.2
Riveline, J.-P.3
Battelino, T.4
Bosi, E.5
Tubiana-Rufi, N.6
Kerr, D.7
Phillip, M.8
-
89
-
-
50049127632
-
Sensor-augmented insulin pump therapy: Results of the first randomized treat-to-target study
-
Hirsch IB, Abelseth J, Bode BW, Fischer JS, Kaufman FR, Mastrototaro J, Parkin CG, Wolpert HA, Buckingham BA: Sensor-augmented insulin pump therapy: results of the first randomized treat-to-target study. Diabetes Technol Ther 2008;10:377-383.
-
(2008)
Diabetes Technol Ther
, vol.10
, pp. 377-383
-
-
Hirsch, I.B.1
Abelseth, J.2
Bode, B.W.3
Fischer, J.S.4
Kaufman, F.R.5
Mastrototaro, J.6
Parkin, C.G.7
Wolpert, H.A.8
Buckingham, B.A.9
-
90
-
-
54849147700
-
Continuous glucose monitoring and intensive treatment of type 1 diabetes
-
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group
-
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group, Tamborlane WV, Beck RW, Bode BW, Buckingham B, Chase HP, Clemons R, Fiallo-Scharer R, Fox LA, Gilliam LK, Hirsch IB, Huang ES, Kollman C, Kowalski AJ, Laffel L, Lawrence JM, Lee J, Mauras N, O'Grady M, Ruedy KJ, Tansey M, Tsalikian E, Weinzimer S, Wilson DM, Wolpert H, Wysocki T, Xing D: Continuous glucose monitoring and intensive treatment of type 1 diabetes. N Engl J Med 2008;359:1464-1476.
-
(2008)
N Engl J Med
, vol.359
, pp. 1464-1476
-
-
Tamborlane, W.V.1
Beck, R.W.2
Bode, B.W.3
Buckingham, B.4
Chase, H.P.5
Clemons, R.6
Fiallo-Scharer, R.7
Fox, L.A.8
Gilliam, L.K.9
Hirsch, I.B.10
Huang, E.S.11
Kollman, C.12
Kowalski, A.J.13
Laffel, L.14
Lawrence, J.M.15
Lee, J.16
Mauras, N.17
O'Grady, M.18
Ruedy, K.J.19
Tansey, M.20
Tsalikian, E.21
Weinzimer, S.22
Wilson, D.M.23
Wolpert, H.24
Wysocki, T.25
Xing, D.26
more..
-
91
-
-
0042018757
-
Continuous glucose monitoring with glucose sensors: Calibration and assessment criteria
-
Glucose Monitoring Study Group
-
Lodwig V, Heinemann L; Glucose Monitoring Study Group: Continuous glucose monitoring with glucose sensors: calibration and assessment criteria. Diabetes Technol Ther 2003;5:572-586.
-
(2003)
Diabetes Technol Ther
, vol.5
, pp. 572-586
-
-
Lodwig, V.1
Heinemann, L.2
-
92
-
-
27644565961
-
Limitations of statistical measures of error in assessing the accuracy of continuous glucose sensors
-
DOI 10.1089/dia.2005.7.665
-
Kollman C, Wilson DM, Wysocki T, Tamborlane WV, Beck RW; Diabetes Research in Children Network Study Group: Limitations of statistical measures of error in assessing the accuracy of continuous glucose sensors. Diabetes Technol Ther 2005;7:665-672. (Pubitemid 41572065)
-
(2005)
Diabetes Technology and Therapeutics
, vol.7
, Issue.5
, pp. 665-672
-
-
Kollman, C.1
Wilson, D.M.2
Wysocki, T.3
Tamborlane, W.V.4
Beck, R.W.5
-
93
-
-
54749116022
-
Evaluating clinical accuracy of continuous glucose monitoring systems: Continuous Glucose-Error Grid Analysis (CG-EGA)
-
Clarke WL, Anderson S, Kovatchev B: Evaluating clinical accuracy of continuous glucose monitoring systems: Continuous Glucose-Error Grid Analysis (CG-EGA). Curr Diabetes Rev 2008;4:193-199.
-
(2008)
Curr Diabetes Rev
, vol.4
, pp. 193-199
-
-
Clarke, W.L.1
Anderson, S.2
Kovatchev, B.3
-
94
-
-
38949140865
-
How to assess and compare the accuracy of continuous glucose monitors?
-
DOI 10.1089/dia.2007.0216
-
Wentholt IM, Hart AA, Hoekstra JB, Devries JH: How to assess and compare the accuracy of continuous glucose monitors? Diabetes Technol Ther 2008;10:57-68. (Pubitemid 351230282)
-
(2008)
Diabetes Technology and Therapeutics
, vol.10
, Issue.2
, pp. 57-68
-
-
Wentholt, I.M.E.1
Hart, A.A.M.2
Hoekstra, J.B.L.3
Devries, J.H.4
-
95
-
-
70349249912
-
Interpretation of continuous glucose monitoring data: Glycemic variability and quality of glycemic control
-
Rodbard D: Interpretation of continuous glucose monitoring data: glycemic variability and quality of glycemic control. Diabetes Technol Ther 2009;11:S-55-S-67.
-
(2009)
Diabetes Technol Ther
, vol.11
, pp. 55-67
-
-
Rodbard, D.1
-
96
-
-
18144421498
-
Continuous glucose monitoring: Roadmap for 21st century diabetes therapy
-
DOI 10.2337/diacare.28.5.1231
-
Klonoff DC: Continuous glucose monitoring: roadmap for 21st century diabetes therapy. Diabetes Care 2005;28:1231-1239. (Pubitemid 40616646)
-
(2005)
Diabetes Care
, vol.28
, Issue.5
, pp. 1231-1239
-
-
Klonoff, D.C.1
-
97
-
-
54749139734
-
Implantable continuous glucose sensors
-
Renard E: Implantable continuous glucose sensors. Curr Diabetes Rev 2008;4:169-174.
-
(2008)
Curr Diabetes Rev
, vol.4
, pp. 169-174
-
-
Renard, E.1
-
98
-
-
54749111511
-
Minimally-invasive and non-invasive continuous glucose monitoring systems: Indications, advantages, limitations and clinical aspects
-
De Block C, Vertommen J, Manuel-y-Keenoy B, Van Gaal L: Minimally-invasive and non-invasive continuous glucose monitoring systems: indications, advantages, limitations and clinical aspects. Curr Diabetes Rev 2008;4:159-168.
-
(2008)
Curr Diabetes Rev
, vol.4
, pp. 159-168
-
-
De Block, C.1
Vertommen, J.2
Manuel-Y-Keenoy, B.3
Van Gaal, L.4
-
99
-
-
54749108405
-
Clinical use of real-time continuous glucose monitoring
-
Battelino T, Bolinder J: Clinical use of real-time continuous glucose monitoring. Curr Diabetes Rev 2008;4:218-222.
-
(2008)
Curr Diabetes Rev
, vol.4
, pp. 218-222
-
-
Battelino, T.1
Bolinder, J.2
-
100
-
-
58349120590
-
Continuous glucose monitoring: A review of biochemical perspectives and clinical use in type 1 diabetes
-
Girardina CM, Huota C, Gonthiera M, Delvi E: Continuous glucose monitoring: a review of biochemical perspectives and clinical use in type 1 diabetes. Clin Biochem2009;42:136-142.
-
(2009)
Clin Biochem
, vol.42
, pp. 136-142
-
-
Girardina, C.M.1
Huota, C.2
Gonthiera, M.3
Delvi, E.4
-
101
-
-
58449109698
-
CGM-A technology in evolution
-
Skyler JS: CGM-a technology in evolution. Diabetes Technol Ther 2009;11:63-64.
-
(2009)
Diabetes Technol Ther
, vol.11
, pp. 63-64
-
-
Skyler, J.S.1
-
103
-
-
0027370108
-
The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. Diabetes Control and Complications Trial Research Group
-
The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. Diabetes Control and Complications Trial Research Group. N Engl J Med 1993; 329:977-986.
-
(1993)
N Engl J Med
, vol.329
, pp. 977-986
-
-
|