메뉴 건너뛰기




Volumn 27, Issue 10, 2009, Pages 1319-1325

Hip resurfacing increases bone strains associated with short-term femoral neck fracture

Author keywords

Femoral neck fracture; Finite element analysis; Hip resurfacing

Indexed keywords

ADULT; ARTICLE; BONE INJURY; BONE STRESS; CADAVER; COMPUTER ASSISTED TOMOGRAPHY; FEMUR FRACTURE; FEMUR NECK FRACTURE; FINITE ELEMENT ANALYSIS; GEOMETRY; HIP; HIP PROSTHESIS; HIP RESURFACING; HUMAN; HUMAN TISSUE; IMPLANT; MALE; PRIORITY JOURNAL;

EID: 70349197627     PISSN: 07360266     EISSN: None     Source Type: Journal    
DOI: 10.1002/jor.20884     Document Type: Article
Times cited : (30)

References (33)
  • 2
    • 17044401726 scopus 로고    scopus 로고
    • Complications associated with hip resurfacing arthroplasty
    • DOI 10.1016/j.ocl.2005.01.002
    • Shimmin AJ, Bare J, Back DL. 2005. Complications associated with hip resurfacing arthroplasty. Orthop Clin North Am 36:187-193. (Pubitemid 40503996)
    • (2005) Orthopedic Clinics of North America , vol.36 , Issue.2 , pp. 187-193
    • Shimmin, A.J.1    Bare, J.2    Back, D.L.3
  • 3
    • 33845409669 scopus 로고    scopus 로고
    • A study of implant failure in metal-on-metal surface arthroplasties
    • Campbell P, Beaule PE, Ebramzadeh E, et al. 2006. A study of implant failure in metal-on-metal surface arthroplasties. Clin Orthop Relat Res 453:35-46.
    • (2006) Clin Orthop Relat Res , vol.453 , pp. 35-46
    • Campbell, P.1    Beaule, P.E.2    Ebramzadeh, E.3
  • 4
    • 33645236921 scopus 로고    scopus 로고
    • Biomechanical, morphological, and histological analysis of early failures in hip resurfacing arthroplasty
    • Morlock MM, Bishop N, Ruther W, et al. 2006. Biomechanical, morphological, and histological analysis of early failures in hip resurfacing arthroplasty. Proc Inst Mech Eng [H] 220:333-344.
    • (2006) Proc Inst Mech Eng [H] , vol.220 , pp. 333-344
    • Morlock, M.M.1    Bishop, N.2    Ruther, W.3
  • 5
    • 33845445598 scopus 로고    scopus 로고
    • Surgical variables affect the mechanics of a hip resurfacing system
    • Long JP, Bartel DL. 2006. Surgical variables affect the mechanics of a hip resurfacing system. Clin Orthop Relat Res 453:115-122.
    • (2006) Clin Orthop Relat Res , vol.453 , pp. 115-122
    • Long, J.P.1    Bartel, D.L.2
  • 6
    • 33747360671 scopus 로고    scopus 로고
    • Biomechanics of the Birmingham hip resurfacing arthroplasty
    • Ong KL, Kurtz SM, Manley MT, et al. 2006. Biomechanics of the Birmingham hip resurfacing arthroplasty. J Bone Joint Surg Br 88B:1110-1115.
    • (2006) J Bone Joint Surg Br , vol.88 B , pp. 1110-1115
    • Ong, K.L.1    Kurtz, S.M.2    Manley, M.T.3
  • 7
    • 0742288970 scopus 로고    scopus 로고
    • Fatigue of bovine trabecular bone
    • Moore TL, Gibson LJ. 2003. Fatigue of bovine trabecular bone. J Biomech Eng 125:761-768.
    • (2003) J Biomech Eng , vol.125 , pp. 761-768
    • Moore, T.L.1    Gibson, L.J.2
  • 8
    • 0030040334 scopus 로고    scopus 로고
    • Cyclic mechanical property degradation during fatigue loading of cortical bone
    • Pattin CA, Caler WE, Carter DR. 1996. Cyclic mechanical property degradation during fatigue loading of cortical bone. J Biomech 29:69-79.
    • (1996) J Biomech , vol.29 , pp. 69-79
    • Pattin, C.A.1    Caler, W.E.2    Carter, D.R.3
  • 9
    • 0041836217 scopus 로고    scopus 로고
    • Fatigue microdamage as an essential element of bone mechanics and biology
    • Martin RB. 2003. Fatigue microdamage as an essential element of bone mechanics and biology. Calcif Tissue Int 73:101-107.
    • (2003) Calcif Tissue Int , vol.73 , pp. 101-107
    • Martin, R.B.1
  • 10
    • 0030039250 scopus 로고    scopus 로고
    • A new model for the regulation of bone resorption, with particular reference to the effects of bisphosphonates
    • Parfitt AM, Mundy GR, Roodman GD, et al. 1996. A new model for the regulation of bone resorption, with particular reference to the effects of bisphosphonates. J Bone Miner Res 11:150-159.
    • (1996) J Bone Miner Res , vol.11 , pp. 150-159
    • Parfitt, A.M.1    Mundy, G.R.2    Roodman, G.D.3
  • 11
    • 84972517827 scopus 로고
    • Design and analysis of computer experiments
    • Sacks J, Welch WJ, Mitchell TJ, et al. 1989. Design and analysis of computer experiments. Stat Sci 4:409-423.
    • (1989) Stat Sci , vol.4 , pp. 409-423
    • Sacks, J.1    Welch, W.J.2    Mitchell, T.J.3
  • 12
    • 0027551874 scopus 로고
    • Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
    • Rho JY, Ashman RB, Turner CH. 1993. Young's modulus of trabecular and cortical bone material: ultrasonic and microtensile measurements. J Biomech 26:111-119.
    • (1993) J Biomech , vol.26 , pp. 111-119
    • Rho, J.Y.1    Ashman, R.B.2    Turner, C.H.3
  • 13
    • 0035055590 scopus 로고    scopus 로고
    • Dependence of yield strain of human trabecular bone on anatomic site
    • Morgan EF, Keaveny TM. 2001. Dependence of yield strain of human trabecular bone on anatomic site. J Biomech 34:569-577.
    • (2001) J Biomech , vol.34 , pp. 569-577
    • Morgan, E.F.1    Keaveny, T.M.2
  • 14
    • 0026154992 scopus 로고
    • Estimation of mechanical properties of cortical bone by computed tomography
    • Snyder SM, Schneider E. 1991. Estimation of mechanical properties of cortical bone by computed tomography. J Orthop Res 9:422-431.
    • (1991) J Orthop Res , vol.9 , pp. 422-431
    • Snyder, S.M.1    Schneider, E.2
  • 15
    • 0017837076 scopus 로고
    • Proximal strain distribution in the loaded femur. An in vitro comparison of the distributions in the intact femur and after insertion of different hip-replacement femoral components
    • Oh I, Harris WH. 1978. Proximal strain distribution in the loaded femur: an in vitro comparison of the distributions in the intact femur and after insertion of different hip-replacement femoral components. J Bone Joint Surg Am 60A:75-85. (Pubitemid 8298335)
    • (1978) Journal of Bone and Joint Surgery - Series a , vol.60 A , Issue.1 , pp. 75-85
    • Oh, I.1    Harris, W.H.2
  • 16
    • 0027641060 scopus 로고
    • Hip joint loading during walking and running, measured in two patients
    • DOI 10.1016/0021-9290(93)90058-M
    • Bergmann G, Graichen F, Rohlmann A. 1993. Hip joint loading during walking and running, measured in two patients. J Biomech 26:969-990. (Pubitemid 23220211)
    • (1993) Journal of Biomechanics , vol.26 , Issue.8 , pp. 969-990
    • Bergmann, G.1    Graichen, F.2    Rohlmann, A.3
  • 18
    • 33845771388 scopus 로고    scopus 로고
    • Gait Analysis of Patients with Resurfacing Hip Arthroplasty Compared with Hip Osteoarthritis and Standard Total Hip Arthroplasty
    • DOI 10.1016/j.arth.2006.03.010, PII S0883540306003354
    • Mont MA, Seyler TM, Ragland PS, et al. 2007. Gait analysis of patients with resurfacing hip arthroplasty compared with hip osteoarthritis and standard total hip arthroplasty. J Arthroplasty 22:100-108. (Pubitemid 46014052)
    • (2007) Journal of Arthroplasty , vol.22 , Issue.1 , pp. 100-108
    • Mont, M.A.1    Seyler, T.M.2    Ragland, P.S.3    Starr, R.4    Erhart, J.5    Bhave, A.6
  • 19
    • 0002989262 scopus 로고
    • Force transmitted by joints in the human body
    • Paul JP. 1967. Force transmitted by joints in the human body. Proc Inst Mech Eng 181:8-15.
    • (1967) Proc Inst Mech Eng , vol.181 , pp. 8-15
    • Paul, J.P.1
  • 20
    • 0348223830 scopus 로고    scopus 로고
    • Metal-on- Metal hybrid surface arthroplasty: Two to six-year followup study
    • Amstutz HC, Beaule PE, Dorey FJ, et al. 2004. Metal-on- metal hybrid surface arthroplasty: two to six-year followup study. J Bone Joint Surg Am 86A:28-39.
    • (2004) J Bone Joint Surg Am , vol.86 A , pp. 28-39
    • Amstutz, H.C.1    Beaule, P.E.2    Dorey, F.J.3
  • 21
    • 1642404356 scopus 로고    scopus 로고
    • Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis
    • DOI 10.1302/0301-620X.86B2.14600
    • Daniel J, Pynsent PB, McMinn DJ. 2004. Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis. J Bone Joint Surg 86B:177-184. (Pubitemid 38386853)
    • (2004) Journal of Bone and Joint Surgery - Series B , vol.86 , Issue.2 , pp. 177-184
    • Daniel, J.1    Pynsent, P.B.2    McMinn, D.J.W.3
  • 22
    • 0023923019 scopus 로고
    • Limitations of the continuum assumption in cancellous bone
    • DOI 10.1016/0021-9290(88)90257-6
    • Harrigan TP, Jasty M, Mann RW, et al. 1988. Limitations of the continuum assumption in cancellous bone. J Biomech 21:269-275. (Pubitemid 18126424)
    • (1988) Journal of Biomechanics , vol.21 , Issue.4 , pp. 269-275
    • Harrigan, T.P.1    Jasty, M.2    Mann, R.W.3    Harris, W.H.4
  • 26
    • 0021910633 scopus 로고
    • A cumulative damage model for bone fracture
    • Carter DR, Caler WE. 1985. A cumulative damage model for bone fracture. J Orthop Res 3:84-90.
    • (1985) J Orthop Res , vol.3 , pp. 84-90
    • Carter, D.R.1    Caler, W.E.2
  • 27
    • 0345736933 scopus 로고    scopus 로고
    • Similarity in the fatigue behavior of trabecular bone across site and species
    • Haddock SM, Yeh OC, Mummaneni PV, et al. 2004. Similarity in the fatigue behavior of trabecular bone across site and species. J Biomech 37:181-187.
    • (2004) J Biomech , vol.37 , pp. 181-187
    • Haddock, S.M.1    Yeh, O.C.2    Mummaneni, P.V.3
  • 28
    • 13844257099 scopus 로고    scopus 로고
    • Role of bone turnover in microdamage
    • Schaffler MB. 2003. Role of bone turnover in microdamage. Osteoporos Int 14:73-80.
    • (2003) Osteoporos Int , vol.14 , pp. 73-80
    • Schaffler, M.B.1
  • 29
    • 0031026628 scopus 로고    scopus 로고
    • Bone microdamage and skeletal fragility in osteoporotic and stress fractures
    • Burr DB, Forwood MR, Fyhrie DP, et al. 1997. Bone microdamage and skeletal fragility in osteoporotic and stress fractures. J Bone Miner Res 12:6-15.
    • (1997) J Bone Miner Res , vol.12 , pp. 6-15
    • Burr, D.B.1    Forwood, M.R.2    Fyhrie, D.P.3
  • 30
    • 0026042125 scopus 로고
    • Stress fractures of the hip in Royal Marine recruits under training: A retrospective analysis
    • Stoneham MD, Morgan NV. 1991. Stress fractures of the hip in Royal Marine recruits under training: a retrospective analysis. Br J Sports Med 25:145-148.
    • (1991) Br J Sports Med , vol.25 , pp. 145-148
    • Stoneham, M.D.1    Morgan, N.V.2
  • 32
    • 33947618631 scopus 로고    scopus 로고
    • Changes in femur stress after hip resurfacing arthroplasty: Response to physiological loads
    • DOI 10.1016/j.clinbiomech.2006.12.002, PII S0268003306002440
    • Little JP, Taddei F, Viceconti M, et al. 2007. Changes in femur stress after hip resurfacing arthroplasty: response to physiological loads. Clin Biomech 22:440-448. (Pubitemid 46498366)
    • (2007) Clinical Biomechanics , vol.22 , Issue.4 , pp. 440-448
    • Little, J.P.1    Taddei, F.2    Viceconti, M.3    Murray, D.W.4    Gill, H.S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.