Multi-frequency time-difference complex conductivity imaging of canine and human lungs using the KHU Mark1 EIT system

Author keywords

Complex conductivity; EIT; Lung; Multi frequency; Time difference

Indexed keywords

ELECTRIC IMPEDANCE TOMOGRAPHY; IMAGE RECONSTRUCTION; RESPIRATORY SYSTEM; SAILING VESSELS;

EID: 70149098455     PISSN: 09673334     EISSN: 13616579     Source Type: Journal    
DOI: 10.1088/0967-3334/30/6/S10     Document Type: Article
Times cited : (26)

References (17)
  • 3
    • 0029848303 scopus 로고    scopus 로고
    • Gravity-dependent phenomena in lung ventilation determined by functional EIT
    • Frerichs I, Hahn G and Hellige G 1996 Gravity-dependent phenomena in lung ventilation determined by functional EIT Physiol. Meas. 17 A149-57
    • (1996) Physiol. Meas. , vol.17
    • Frerichs, I.1    Hahn, G.2    Hellige, G.3
  • 4
    • 0034039948 scopus 로고    scopus 로고
    • Electrical impedance tomography (EIT) in applications related to lung and ventilation: A review of experimental and clinical activities
    • Frerichs I 2000 Electrical impedance tomography (EIT) in applications related to lung and ventilation: a review of experimental and clinical activities Physiol. Meas. 21 R1-21
    • (2000) Physiol. Meas. , vol.21 , Issue.2 , pp. 1-21
    • Frerichs, I.1
  • 5
    • 0029845456 scopus 로고    scopus 로고
    • Local mechanics of the lung tissue determined by functional EIT
    • Hahn G, Frerichs I, Kleyer M and Hellige G 1996 Local mechanics of the lung tissue determined by functional EIT Physiol. Meas. 17 A159-66
    • (1996) Physiol. Meas. , vol.17
    • Hahn, G.1    Frerichs, I.2    Kleyer, M.3    Hellige, G.4
  • 7
    • 0029082881 scopus 로고
    • Changes in the thoracic impedance distribution under different ventilatory conditions
    • Hahn G, Sipinkova I, Baisch F and Hellige G 1995 Changes in the thoracic impedance distribution under different ventilatory conditions Physiol. Meas. 16 A161-73
    • (1995) Physiol. Meas. , vol.16
    • Hahn, G.1    Sipinkova, I.2    Baisch, F.3    Hellige, G.4
  • 9
    • 58149295820 scopus 로고    scopus 로고
    • In vivo electrical conductivity imaging of a canine brain using a 3 T MREIT system
    • Kim H J et al 2008 In vivo electrical conductivity imaging of a canine brain using a 3 T MREIT system Physiol. Meas. 29 1145-55
    • (2008) Physiol. Meas. , vol.29 , Issue.10 , pp. 1145-1155
    • Kim, H.J.1    Al, E.2
  • 12
    • 41049091399 scopus 로고    scopus 로고
    • Validation of a multi-frequency electrical impedance tomography (mfEIT) system KHU Mark1: Impedance spectroscopy and time-difference imaging
    • Oh T I, Koo W, Lee K H, Kim S M, Lee J, Kim S W, Seo J K and Woo E J 2008 Validation of a multi-frequency electrical impedance tomography (mfEIT) system KHU Mark1: impedance spectroscopy and time-difference imaging Physiol. Meas. 29 295-307
    • (2008) Physiol. Meas. , vol.29 , Issue.3 , pp. 295-307
    • Oh, T.I.1    Koo, W.2    Lee, K.H.3    Kim, S.M.4    Lee, J.5    Kim, S.W.6    Seo, J.K.7    Woo, E.J.8
  • 13
    • 36049027812 scopus 로고    scopus 로고
    • Calibration methods for a multi-channel multi-frequency EIT system
    • DOI 10.1088/0967-3334/28/10/004, PII S0967333407478091
    • Oh T I, Lee K H, Kim S M, Koo W, Woo E J and Holder D 2007b Calibration methods for a multi-channel multi-frequency EIT system Physiol. Meas. 28 1175-88 (Pubitemid 350093339)
    • (2007) Physiological Measurement , vol.28 , Issue.10 , pp. 1175-1188
    • Oh, T.I.1    Lee, K.H.2    Kim, S.M.3    Koo, H.4    Woo, E.J.5    Holder, D.6
  • 14
    • 34447092724 scopus 로고    scopus 로고
    • Multi-frequency EIT system with radially symmetric architecture: KHU Mark1
    • Oh T I, Woo E J and Holder D 2007a Multi-frequency EIT system with radially symmetric architecture: KHU Mark1 Physiol. Meas. 28 S183-96
    • (2007) Physiol. Meas. , vol.28 , Issue.7
    • Oh, T.I.1    Woo, E.J.2    Holder, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.