메뉴 건너뛰기




Volumn 27, Issue 5, 2006, Pages

Imaging pathologic pulmonary air and fluid accumulation by functional and absolute EIT

Author keywords

EIT; Functional imaging; Impedance tomography; Lung impedance; Lung water; Static imaging

Indexed keywords

AIR; CLINICAL RESEARCH; COMPUTERIZED TOMOGRAPHY; ELECTRIC IMPEDANCE; ELECTRIC IMPEDANCE MEASUREMENT; ELECTRIC IMPEDANCE TOMOGRAPHY; ITERATIVE METHODS; PATHOLOGY;

EID: 33745175209     PISSN: 09673334     EISSN: 13616579     Source Type: Journal    
DOI: 10.1088/0967-3334/27/5/S16     Document Type: Conference Paper
Times cited : (88)

References (10)
  • 1
    • 0025685350 scopus 로고
    • Quantification in impedance imaging
    • Barber D C 1990 Quantification in impedance imaging Clin. Phys. Physiol. Meas. 11 (Suppl. A) 45-56
    • (1990) Clin. Phys. Physiol. Meas. , vol.11 , Issue.SUPPL. A , pp. 45-56
    • Barber, D.C.1
  • 3
    • 0034975827 scopus 로고    scopus 로고
    • Gravity effects on regional lung ventilation determined by functional EIT during parabolic flights
    • Frerichs I, Dudykevych T, Hinz J, Bodenstein M, Hahn G and Hellige G 2001 Gravity effects on regional lung ventilation determined by functional EIT during parabolic flights J. Appl. Physiol. 91 39-50
    • (2001) J. Appl. Physiol. , vol.91 , pp. 39-50
    • Frerichs, I.1    Dudykevych, T.2    Hinz, J.3    Bodenstein, M.4    Hahn, G.5    Hellige, G.6
  • 5
    • 0029954935 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: I. Literature survey
    • Gabriel C, Gabriel S and Corthout E 1996 The dielectric properties of biological tissues: I. Literature survey Phys. Med. Biol. 41 2231-49
    • (1996) Phys. Med. Biol. , vol.41 , Issue.11 , pp. 2231-2249
    • Gabriel, C.1    Gabriel, S.2    Corthout, E.3
  • 6
    • 0348052290 scopus 로고    scopus 로고
    • A high performance electrical impedance tomography (EIT) system for clinical evaluation studies and space application
    • Hahn G, Dudykevych T, Frerichs I, Thiel F and Hellige G 2002 A high performance electrical impedance tomography (EIT) system for clinical evaluation studies and space application Proc. Conf. 2nd European Medical and Biological Engineering ed H Hutten and P Krösl (Graz: Verlag der TU Graz) pp 110-1
    • (2002) Proc. Conf. 2nd European Medical and Biological Engineering , pp. 110-111
    • Hahn, G.1    Dudykevych, T.2    Frerichs, I.3    Thiel, F.4    Hellige, G.5
  • 7
    • 0029082881 scopus 로고
    • Changes in the thoracic impedance distribution under different ventilatory conditions
    • Hahn G, Sipinkova I, Baisch F and Hellige G 1995 Changes in the thoracic impedance distribution under different ventilatory conditions Physiol. Meas. 16 (Suppl. A) 161-73
    • (1995) Physiol. Meas. , vol.16 , Issue.SUPPL. A , pp. 161-173
    • Hahn, G.1    Sipinkova, I.2    Baisch, F.3    Hellige, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.