메뉴 건너뛰기




Volumn 9, Issue 4, 2008, Pages 68-86

Simulation of intrafraction motion and overall geometric accuracy of a frameless intracranial radiosurgery process

Author keywords

Clinical accuracy; Frameless stereotactic radiosurgery; Intrafraction motion; Optical tracking; PTV margin

Indexed keywords


EID: 70049096052     PISSN: None     EISSN: 15269914     Source Type: Journal    
DOI: 10.1120/jacmp.v9i4.2828     Document Type: Article
Times cited : (31)

References (40)
  • 2
    • 0037234447 scopus 로고    scopus 로고
    • An analysis of the accuracy of the CyberKnife: a robotic frameless stereotactic radiosurgical system
    • Chang SD, Main W, Martin DP, Gibbs IC, Heilbrun MP. An analysis of the accuracy of the CyberKnife: a robotic frameless stereotactic radiosurgical system. Neurosurgery. 2003;52(1):140-147.
    • (2003) Neurosurgery , vol.52 , Issue.1 , pp. 140-147
    • Chang, S.D.1    Main, W.2    Martin, D.P.3    Gibbs, I.C.4    Heilbrun, M.P.5
  • 3
    • 38849151582 scopus 로고    scopus 로고
    • Contemporary methods of radiosurgery treatment with the Novalis linear accelerator system
    • Chen JC, Rahimian J, Girvigian MR, Miller MJ. Contemporary methods of radiosurgery treatment with the Novalis linear accelerator system. Neurosurg Focus. 2007;23(6):E4.
    • (2007) Neurosurg Focus , vol.23 , Issue.6
    • Chen, J.C.1    Rahimian, J.2    Girvigian, M.R.3    Miller, M.J.4
  • 4
    • 33846947728 scopus 로고    scopus 로고
    • New frontiers in radiosurgery for the brain and body
    • Giller CA, Berger BD. New frontiers in radiosurgery for the brain and body. Proc (Bayl Univ Med Cent). 2005;18(4):311-320.
    • (2005) Proc (Bayl Univ Med Cent) , vol.18 , Issue.4 , pp. 311-320
    • Giller, C.A.1    Berger, B.D.2
  • 6
    • 0035889332 scopus 로고    scopus 로고
    • Initial clinical experience with frameless stereotactic radiosurgery: analysis of accuracy and feasibility
    • Ryken TC, Meeks SL, Pennington EC, et al. Initial clinical experience with frameless stereotactic radiosurgery: analysis of accuracy and feasibility. Int J Radiat Oncol Biol Phys. 2001;51(4):1152-1158.
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , Issue.4 , pp. 1152-1158
    • Ryken, T.C.1    Meeks, S.L.2    Pennington, E.C.3
  • 8
    • 0036121896 scopus 로고    scopus 로고
    • Quality assurance in stereotactic space. A system test for verifying the accuracy of aim in radiosurgery
    • Mack A, Czempiel H, Kreiner HJ, Dürr G, Wowra B. Quality assurance in stereotactic space. A system test for verifying the accuracy of aim in radiosurgery. Med Phys. 2002;29(4):561-568.
    • (2002) Med Phys , vol.29 , Issue.4 , pp. 561-568
    • Mack, A.1    Czempiel, H.2    Kreiner, H.J.3    Dürr, G.4    Wowra, B.5
  • 9
    • 0347625753 scopus 로고    scopus 로고
    • A phantom study on the positioning accuracy of the Novalis Body system
    • Yan H, Yin FF, Kim JH. A phantom study on the positioning accuracy of the Novalis Body system. Med Phys. 2003;30(12):3052-3060.
    • (2003) Med Phys , vol.30 , Issue.12 , pp. 3052-3060
    • Yan, H.1    Yin, F.F.2    Kim, J.H.3
  • 10
    • 70049097694 scopus 로고    scopus 로고
    • SU-FF-T-75: accuracy assessment of a non-invasive image guided system for intra-cranial LINAC based stereotactic radiosurgery [Abstract]
    • Rosca F, Lorenz F, Hacker FL, Chin LM, Ramakrishna N, Zygmanski P. SU-FF-T-75: accuracy assessment of a non-invasive image guided system for intra-cranial LINAC based stereotactic radiosurgery [Abstract]. Med Phys. 2006;33(6):2066.
    • (2006) Med Phys , vol.33 , Issue.6 , pp. 2066
    • Rosca, F.1    Lorenz, F.2    Hacker, F.L.3    Chin, L.M.4    Ramakrishna, N.5    Zygmanski, P.6
  • 11
    • 7244247111 scopus 로고    scopus 로고
    • Geometrical accuracy of the Novalis stereotactic radiosurgery system for trigeminal neuralgia
    • Rahimian J, Chen JC, Rao AA, Girvigian MR, Miller MJ, Greathouse HE. Geometrical accuracy of the Novalis stereotactic radiosurgery system for trigeminal neuralgia. J Neurosurg. 2004;101(Suppl 3):351-355.
    • (2004) J Neurosurg , vol.101 , Issue.SUPPL. 3 , pp. 351-355
    • Rahimian, J.1    Chen, J.C.2    Rao, A.A.3    Girvigian, M.R.4    Miller, M.J.5    Greathouse, H.E.6
  • 12
    • 70049083011 scopus 로고    scopus 로고
    • SU-FF-J-08: accuracy of cranial co-planar beam therapy with BrainLAB ExacTrac image guidance [Abstract]
    • Vinci J, Hogström K, Rosen I, et al. SU-FF-J-08: accuracy of cranial co-planar beam therapy with BrainLAB ExacTrac image guidance [Abstract]. Med Phys. 2007;34(6):2369.
    • (2007) Med Phys , vol.34 , Issue.6 , pp. 2369
    • Vinci, J.1    Hogström, K.2    Rosen, I.3
  • 13
    • 31844439099 scopus 로고    scopus 로고
    • Six dimensional analysis with daily stereoscopic X-ray imaging of intrafraction patient motion in head and neck treatments using five points fixation masks
    • Linthout N, Verellen D, Tournel K, Storme G. Six dimensional analysis with daily stereoscopic X-ray imaging of intrafraction patient motion in head and neck treatments using five points fixation masks. Med Phys. 2006;33(2):504-513.
    • (2006) Med Phys , vol.33 , Issue.2 , pp. 504-513
    • Linthout, N.1    Verellen, D.2    Tournel, K.3    Storme, G.4
  • 14
    • 35648979993 scopus 로고    scopus 로고
    • Effects of residual target motion for image-tracked spine radiosurgery
    • Chuang C, Sahgal A, Lee L, et al. Effects of residual target motion for image-tracked spine radiosurgery. Med Phys. 2007;34(11):4484-4490.
    • (2007) Med Phys , vol.34 , Issue.11 , pp. 4484-4490
    • Chuang, C.1    Sahgal, A.2    Lee, L.3
  • 15
  • 16
    • 1642266409 scopus 로고    scopus 로고
    • Evaluation of intrafraction patient movement for CNS and head and neck IMRT
    • Kim S, Akpati HC, Kielbasa JE, et al. Evaluation of intrafraction patient movement for CNS and head and neck IMRT. Med Phys. 2004;31(3):500-506.
    • (2004) Med Phys , vol.31 , Issue.3 , pp. 500-506
    • Kim, S.1    Akpati, H.C.2    Kielbasa, J.E.3
  • 18
    • 33751176878 scopus 로고    scopus 로고
    • Repositioning accuracy of two different mask systems-3D revisited: comparison using true 3D/3D matching with cone-beam CT
    • Boda-Heggemann J, Walter C, Rahn A, et al. Repositioning accuracy of two different mask systems-3D revisited: comparison using true 3D/3D matching with cone-beam CT. Int J Radiat Oncol Biol Phys. 2006;66(5):1568-1575.
    • (2006) Int J Radiat Oncol Biol Phys , vol.66 , Issue.5 , pp. 1568-1575
    • Boda-Heggemann, J.1    Walter, C.2    Rahn, A.3
  • 20
    • 0035252566 scopus 로고    scopus 로고
    • Comparison of setup accuracy of three different thermoplastic masks for the treatment of brain and head and neck tumors
    • Gilbeau L, Octave-Prignot M, Loncol T, Renard L, Scalliet P, Grégoire V. Comparison of setup accuracy of three different thermoplastic masks for the treatment of brain and head and neck tumors. Radiother Oncol. 2001;58(2):155-162.
    • (2001) Radiother Oncol , vol.58 , Issue.2 , pp. 155-162
    • Gilbeau, L.1    Octave-Prignot, M.2    Loncol, T.3    Renard, L.4    Scalliet, P.5    Grégoire, V.6
  • 21
    • 70049096743 scopus 로고    scopus 로고
    • SU-FF-T-220: evaluation of a prototype thermoplastic mask using the Novalis Body system
    • Gajdos S, Clouser E, Djemil T. SU-FF-T-220: evaluation of a prototype thermoplastic mask using the Novalis Body system. Med Phys. 2006;33(6):2098-2099.
    • (2006) Med Phys , vol.33 , Issue.6 , pp. 2098-2099
    • Gajdos, S.1    Clouser, E.2    Djemil, T.3
  • 22
    • 0023875610 scopus 로고
    • A system for stereotactic radiosurgery with a linear accelerator
    • Lutz W, Winston KR, Maleki N. A system for stereotactic radiosurgery with a linear accelerator. Int J Radiat Oncol Biol Phys. 1988;14(2):373-381.
    • (1988) Int J Radiat Oncol Biol Phys , vol.14 , Issue.2 , pp. 373-381
    • Lutz, W.1    Winston, K.R.2    Maleki, N.3
  • 23
    • 33750564064 scopus 로고    scopus 로고
    • Sensitivity of linear CCD array based film scanners used for film dosimetry
    • Devic S, Wang YZ, Tomic N, Podgorsak EB. Sensitivity of linear CCD array based film scanners used for film dosimetry. Med Phys. 2006;33(11):3993-3996.
    • (2006) Med Phys , vol.33 , Issue.11 , pp. 3993-3996
    • Devic, S.1    Wang, Y.Z.2    Tomic, N.3    Podgorsak, E.B.4
  • 25
    • 0038030020 scopus 로고    scopus 로고
    • Quality assurance of a system for improved target localization and patient set-up that combines real-time infrared tracking and stereoscopic X-ray imaging
    • Verellen D, Soete G, Linthout N, et al. Quality assurance of a system for improved target localization and patient set-up that combines real-time infrared tracking and stereoscopic X-ray imaging. Radiother Oncol. 2003;67(1):129-141.
    • (2003) Radiother Oncol , vol.67 , Issue.1 , pp. 129-141
    • Verellen, D.1    Soete, G.2    Linthout, N.3
  • 26
    • 0345700623 scopus 로고    scopus 로고
    • Patterns of patient movement during frameless image-guided radiosurgery
    • Murphy MJ, Chang SD, Gibbs IC, et al. Patterns of patient movement during frameless image-guided radiosurgery. Int J Radiat Oncol Biol Phys. 2003;55(5):1400-1408.
    • (2003) Int J Radiat Oncol Biol Phys , vol.55 , Issue.5 , pp. 1400-1408
    • Murphy, M.J.1    Chang, S.D.2    Gibbs, I.C.3
  • 27
    • 70049100701 scopus 로고    scopus 로고
    • SU-FF-J-120: patient motion during extracranial stereotactic radiosurgery [Abstract]
    • Dieterich S, Xia Y. SU-FF-J-120: patient motion during extracranial stereotactic radiosurgery [Abstract]. Med Phys. 2005;32(6):1947-1948.
    • (2005) Med Phys , vol.32 , Issue.6 , pp. 1947-1948
    • Dieterich, S.1    Xia, Y.2
  • 28
    • 0037402523 scopus 로고    scopus 로고
    • Isocenter accuracy in frameless stereotactic radiotherapy using implanted fiducials
    • Kim KH, Cho MJ, Kim JS, et al. Isocenter accuracy in frameless stereotactic radiotherapy using implanted fiducials. Int J Radiat Oncol Biol Phys. 2003;56(1):266-273.
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , Issue.1 , pp. 266-273
    • Kim, K.H.1    Cho, M.J.2    Kim, J.S.3
  • 30
    • 0032776206 scopus 로고    scopus 로고
    • Planning target volumes for radiotherapy: how much margin is needed?
    • Antolak JA, Rosen, II. Planning target volumes for radiotherapy: how much margin is needed? Int J Radiat Oncol Biol Phys. 1999;44(5):1165-1170.
    • (1999) Int J Radiat Oncol Biol Phys , vol.44 , Issue.5 , pp. 1165-1170
    • Antolak, J.A.1    Rosen, I.I.2
  • 31
    • 34247495968 scopus 로고    scopus 로고
    • Convolution method and CTV-to-PTV margins for finite fractions and small systematic errors
    • Gordon JJ, Siebers JV. Convolution method and CTV-to-PTV margins for finite fractions and small systematic errors. Phys Med Biol. 2007;52(7):1967-1990.
    • (2007) Phys Med Biol , vol.52 , Issue.7 , pp. 1967-1990
    • Gordon, J.J.1    Siebers, J.V.2
  • 33
    • 85024955434 scopus 로고    scopus 로고
    • PTV margin determination in conformal SRT of intracranial lesions
    • Parker BC, Shiu AS, Maor MH, et al. PTV margin determination in conformal SRT of intracranial lesions. J Appl Clin Med Phys. 2002;3(3):176-189.
    • (2002) J Appl Clin Med Phys , vol.3 , Issue.3 , pp. 176-189
    • Parker, B.C.1    Shiu, A.S.2    Maor, M.H.3
  • 34
    • 0033041247 scopus 로고    scopus 로고
    • Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability
    • Stroom JC, de Boer HC, Huizenga H, Visser AG. Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability. Int J Radiat Oncol Biol Phys. 1999;43(4):905-919.
    • (1999) Int J Radiat Oncol Biol Phys , vol.43 , Issue.4 , pp. 905-919
    • Stroom, J.C.1    de Boer, H.C.2    Huizenga, H.3    Visser, A.G.4
  • 35
    • 0036661305 scopus 로고    scopus 로고
    • Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report
    • Stroom JC, Heijmen BJ. Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report. Radiother Oncol. 2002;64(1):75-83.
    • (2002) Radiother Oncol , vol.64 , Issue.1 , pp. 75-83
    • Stroom, J.C.1    Heijmen, B.J.2
  • 36
    • 0036534905 scopus 로고    scopus 로고
    • Inclusion of geometric uncertainties in treatment plan evaluation
    • van Herk M, Remeijer P, Lebesque JV. Inclusion of geometric uncertainties in treatment plan evaluation. Int J Radiat Oncol Biol Phys. 2002;52(5):1407-1422.
    • (2002) Int J Radiat Oncol Biol Phys , vol.52 , Issue.5 , pp. 1407-1422
    • van Herk, M.1    Remeijer, P.2    Lebesque, J.V.3
  • 37
    • 0034237797 scopus 로고    scopus 로고
    • The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy
    • van Herk M, Remeijer P, Rasch C, Lebesque JV. The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. Int J Radiat Oncol Biol Phys. 2000;47(4):1121-1135.
    • (2000) Int J Radiat Oncol Biol Phys , vol.47 , Issue.4 , pp. 1121-1135
    • van Herk, M.1    Remeijer, P.2    Rasch, C.3    Lebesque, J.V.4
  • 38
    • 37049030610 scopus 로고    scopus 로고
    • Planning target margin calculations for prostate radiotherapy based on intrafraction and interfraction motion using four localization methods
    • Beltran C, Herman MG, Davis BJ. Planning target margin calculations for prostate radiotherapy based on intrafraction and interfraction motion using four localization methods. Int J Radiat Oncol Biol Phys. 2008;70(1):289-295.
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , Issue.1 , pp. 289-295
    • Beltran, C.1    Herman, M.G.2    Davis, B.J.3
  • 39
    • 0032721315 scopus 로고    scopus 로고
    • Evaluation of the spatial accuracy of magnetic resonance imaging-based stereotactic target localization for Gamma Knife radiosurgery of functional disorders
    • Bednarz G, Downes MB, Corn BW, Curran WJ, Goldman HW. Evaluation of the spatial accuracy of magnetic resonance imaging-based stereotactic target localization for Gamma Knife radiosurgery of functional disorders. Neurosurgery. 1999;45(5):1156-1163.
    • (1999) Neurosurgery , vol.45 , Issue.5 , pp. 1156-1163
    • Bednarz, G.1    Downes, M.B.2    Corn, B.W.3    Curran, W.J.4    Goldman, H.W.5
  • 40
    • 0036894589 scopus 로고    scopus 로고
    • Effect of subpixel magnetic resonance imaging shifts on radiosurgical dosimetry for vestibular schwannoma
    • Borden JA, Tsai JS, Mahajan A. Effect of subpixel magnetic resonance imaging shifts on radiosurgical dosimetry for vestibular schwannoma. J Neurosurg. 2002;97(Suppl 5):445-449.
    • (2002) J Neurosurg , vol.97 , Issue.SUPPL. 5 , pp. 445-449
    • Borden, J.A.1    Tsai, J.S.2    Mahajan, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.