메뉴 건너뛰기




Volumn 55, Issue 5, 2003, Pages 1400-1408

Patterns of patient movement during frameless image-guided radiosurgery

Author keywords

Frameless radiosurgery; Image guidance; Radiation therapy

Indexed keywords

AMORPHOUS SILICON; DEGREES OF FREEDOM (MECHANICS); IMAGING SYSTEMS; TUMORS; X RAY CAMERAS;

EID: 0345700623     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0360-3016(02)04597-2     Document Type: Article
Times cited : (137)

References (7)
  • 1
    • 76949138594 scopus 로고
    • The stereotactic method and radiosurgery of the brain
    • Leksell L. The stereotactic method and radiosurgery of the brain. Acta Chir Scand. 102:1951;316-319.
    • (1951) Acta Chir Scand , vol.102 , pp. 316-319
    • Leksell, L.1
  • 2
    • 0003498685 scopus 로고
    • Stereotactic radiosurgery
    • Boston: American Association of Physicists in Medicine
    • Schell MC, Bova FJ, Larson DA, et al. Stereotactic radiosurgery. In: AAPM Task Group 42 Report. Boston: American Association of Physicists in Medicine; 1995; 54:6-8.
    • (1995) AAPM Task Group 42 Report , vol.54 , pp. 6-8
    • Schell, M.C.1    Bova, F.J.2    Larson, D.A.3
  • 3
    • 0035889332 scopus 로고    scopus 로고
    • Initial clinical experience with frameless stereotactic radiosurgery: Analysis of accuracy and feasibility
    • Ryken T.C., Meeks S.L., Pennington E.C., et al. Initial clinical experience with frameless stereotactic radiosurgery Analysis of accuracy and feasibility. Int J Radiat Oncol Biol Phys. 51:2001;1152-1158.
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 1152-1158
    • Ryken, T.C.1    Meeks, S.L.2    Pennington, E.C.3
  • 5
    • 0030940761 scopus 로고    scopus 로고
    • An automatic six-degree-of-freedom image registration algorithm for image-guided frameless stereotaxic radiosurgery
    • Murphy M.J. An automatic six-degree-of-freedom image registration algorithm for image-guided frameless stereotaxic radiosurgery. Med Phys. 24:1997;857-866.
    • (1997) Med Phys , vol.24 , pp. 857-866
    • Murphy, M.J.1
  • 6
    • 0032936814 scopus 로고    scopus 로고
    • The importance of computed tomography slice thickness in radiographic patient positioning for radiosurgery
    • Murphy M.J. The importance of computed tomography slice thickness in radiographic patient positioning for radiosurgery. Med Phys. 26:1999;171-175.
    • (1999) Med Phys , vol.26 , pp. 171-175
    • Murphy, M.J.1
  • 7
    • 0036603745 scopus 로고    scopus 로고
    • The effectiveness of breathholding to stabilize lung and pancreas tumors during radiosurgery
    • Murphy M.J., Martin D., Whyte R., et al. The effectiveness of breathholding to stabilize lung and pancreas tumors during radiosurgery. Int J Radiat Oncol Biol Phys. 53:2002;475-482.
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 475-482
    • Murphy, M.J.1    Martin, D.2    Whyte, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.