메뉴 건너뛰기




Volumn 7365, Issue , 2009, Pages

Novel method for a flexible double sided microelectrode fabrication process

Author keywords

Double sided flexible micro electrodes; Flexible substrate; Neuroprosthetics; Polyimide

Indexed keywords

ACTIVE SITE; APPLICATION PERFORMANCE; BIOLOGICAL TISSUES; CHARACTERISATION; DOUBLE SIDED; DOUBLE SIDED FLEXIBLE MICRO ELECTRODES; ELASTIC STRUCTURES; ELECTRODE ARRANGEMENT; ELECTRODE SITES; ELECTRODE SYSTEMS; FLEXIBLE DEVICE; FLEXIBLE ELECTRODES; FLEXIBLE SUBSTRATE; HIGH YIELD; IN-VITRO; LOW-YIELD; MECHANICAL BEHAVIOUR; MICROELECTRODE FABRICATION; NEUROPROSTHETICS; NOVEL METHODS; SIGNAL RECORDING; SINGLE ELECTRODES; SINGLE-SIDED DEVICE; SUBSTRATE MATERIAL;

EID: 70049083118     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.821649     Document Type: Conference Paper
Times cited : (3)

References (30)
  • 2
    • 2342663231 scopus 로고    scopus 로고
    • A demonstration of man of electromotive changes accompanying the heart́s beat
    • Waller, A.D.: "A Demonstration of Man of Electromotive Changes Accompanying the Heart́s Beat". Annals of Noninvasive Electrocardiology 9, 189-191 (2004).
    • (2004) Annals of Noninvasive Electrocardiology , vol.9 , pp. 189-191
    • Waller, A.D.1
  • 10
    • 10944240893 scopus 로고    scopus 로고
    • Peripheral nerve and muscle stimulation
    • (Hrsg.: Horch, K.W.; Dhillon, G.S.), World Scientific, Hackensack, New Jersey, S.
    • Mortimer, J.T.; Bhadra, N.: "Peripheral Nerve and Muscle Stimulation". In ., Neuroprosthetics: Theory and Practice (Hrsg.: Horch, K.W.; Dhillon, G.S.), World Scientific, Hackensack, New Jersey, S. 638-682 (2004).
    • (2004) Neuroprosthetics: Theory and Practice , pp. 638-682
    • Mortimer, J.T.1    Bhadra, N.2
  • 11
    • 12344323809 scopus 로고    scopus 로고
    • Electrical stimulation of excitable tissue: Design of efficacious and safe protocols
    • Merrill, D.R.; Bikson, M.; Jefferys, J.G.R.. "Electrical stimulation of excitable tissue: design of efficacious and safe protocols". Journal of Neuroscience Methods 141, 171-198 (2005).
    • (2005) Journal of Neuroscience Methods 141 , pp. 171-198
    • Merrill, D.R.1    Bikson, M.2    Jefferys, J.G.R.3
  • 16
    • 1542287962 scopus 로고    scopus 로고
    • Safety and efficacy of spinal cord stimulation for the treatment of chronic pain: a 20 year literature review
    • Cameron, T.: "Safety and efficacy of spinal cord stimulation for the treatment of chronic pain: a 20 year literature review". Journal of Neurosurgery 100, 254-267 (2004).
    • (2004) Journal of Neurosurgery 100 , pp. 254-267
    • Cameron, T.1
  • 22
    • 80053529933 scopus 로고    scopus 로고
    • Biosignale erfassen und verarbeiten
    • (Hrsg.: Kramme, R.) 3. Auflage, Springer, Berlin, Heidelberg, S.
    • Hoffmann, K.-P.: ., Biosignale erfassen und verarbeiten". In ., Medizintechnik" (Hrsg.: Kramme, R.), 3. Auflage, Springer, Berlin, Heidelberg, S. 617-638 (2007a).
    • (2007) Medizintechnik , pp. 617-638
    • Hoffmann, K.-P.1
  • 23
    • 27644591279 scopus 로고    scopus 로고
    • A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems
    • Navarro, X.; Krüger, T.B.; Lago, N.; Micera, S.; Stieglitz, T.; Dario, P.: ., A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems". Journal of the Peripheral Nervous System 10, 229-258 (2005).
    • (2005) Journal of the Peripheral Nervous System 10 , pp. 229-258
    • Navarro, X.1    Krüger, T.B.2    Lago, N.3    Micera, S.4    Stieglitz, T.5    Dario, P.6
  • 29
    • 0000215292 scopus 로고    scopus 로고
    • Flexible biomedical microdevices with double-sided electrode arrangements for neural applications
    • Stieglitz, T. : "Flexible biomedical microdevices with double-sided electrode arrangements for neural applications". Sensors and Actuators A Phys. A 90 (2001) 203-211
    • (2001) Sensors and Actuators A Phys. A 90 , pp. 203-211
    • Stieglitz, T.1
  • 30
    • 0037086015 scopus 로고    scopus 로고
    • Flexible BIOMEMS with electrode arrangements on front and back side as key component in neural prostheses and biohybrid systems
    • Stieglitz, T.; Gross, M. : "Flexible BIOMEMS with electrode arrangements on front and back side as key component in neural prostheses and biohybrid systems". Sensors and Actuators B83 (2002), 8-14
    • (2002) Sensors and Actuators B83 , pp. 8-14
    • Stieglitz, T.1    Gross, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.