Volumn 36, Issue 9, 2009, Pages 3945-3954

Measurements of dose discrepancies due to inhomogeneities and radiographic contrast in balloon catheter brachytherapy

Author keywords

Breast HDR brachytherapy; Dose discrepancies; MOSFET

Indexed keywords

BALLOONS; CATHETERS; METALS; MOS DEVICES; MOSFET DEVICES; OXIDE SEMICONDUCTORS; POLYMETHYL METHACRYLATES; RADIOTHERAPY;

EID: 69549096004     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3183497     Document Type: Article
Times cited : (7)

References (20)
  • 3
    • 0037126341 scopus 로고    scopus 로고
    • Twenty-year follow-up of a randomized trial comparing total mastectomy, lumpectomy, and lumpectomy plus irradiation for the treatment of invasive breast cancer
    • DOI 10.1056/NEJMoa022152
    • B. Fisher, " Twenty-year follow-up of a randomized trial comparing total mastectomy, lumpectomy and lumpectomy plus irradiation for the treatment of invasive breast cancer.," N. Engl. J. Med. 0028-4793 347, 1233-1241 (2002). 10.1056/NEJMoa022152 (Pubitemid 35176242)
    • (2002) New England Journal of Medicine , vol.347 , Issue.16 , pp. 1233-1241
    • Fisher, B.1    Anderson, S.2    Bryant, J.3    Margolese, R.G.4    Deutsch, M.5    Fisher, E.R.6    Jeong, J.-H.7    Wolmark, N.8
  • 4
    • 0034594654 scopus 로고    scopus 로고
    • Travel distance to radiation therapy and receipt of radiotherapy following breast-conserving surgery
    • 0027-8874,. 10.1093/jnci/92.3.269
    • W. F. Athas, M. Adams-Cameron, W. C. Hunt, A. Amir-Fazli, and C. R. Key, " Travel distance to radiation therapy and receipt of radiotherapy following breast-conserving surgery.," J. Natl. Cancer Inst. 0027-8874 92, 269-271 (2000). 10.1093/jnci/92.3.269
    • (2000) J. Natl. Cancer Inst. , vol.92 , pp. 269-271
    • Athas, W.F.1    Adams-Cameron, M.2    Hunt, W.C.3    Amir-Fazli, A.4    Key, C.R.5
  • 5
    • 0037085979 scopus 로고    scopus 로고
    • Dosimetric characteristics of the MammoSite RTS, a new breast brachytherapy applicator
    • DOI 10.1016/S0360-3016(01)02773-0, PII S0360301601027730
    • G. K. Edmundson, F. A. Vicini, P. E. Chen, C. Mitchell, and A. A. Martinez, " Dosimetric characteristics of the MammoSite RTS, a new breast brachytherapy applicator.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 52, 1132-1139 (2002). 10.1016/S0360-3016(01)02773-0 (Pubitemid 34219036)
    • (2002) International Journal of Radiation Oncology Biology Physics , vol.52 , Issue.4 , pp. 1132-1139
    • Edmundson, G.K.1    Vicini, F.A.2    Chen, P.Y.3    Mitchell, C.4    Martinez, A.A.5
  • 8
    • 2442641529 scopus 로고    scopus 로고
    • Dose perturbation induced by radiographic contrast inside brachytherapy balloon applicators
    • DOI 10.1118/1.1705445
    • M. C. Kirk, W. C. His, J. C. H. Chu, N. Niu, and Z. Hu, " Dose perturbation induced by radiographic contrast inside brachytherapy balloon applicator.," Med. Phys. 0094-2405 31, 1219-1224 (2004). 10.1118/1.1705445 (Pubitemid 38656795)
    • (2004) Medical Physics , vol.31 , Issue.5 , pp. 1219-1224
    • Kirk, M.C.1    Hsi, W.C.2    Chu, J.C.H.3    Niu, H.4    Hu, Z.5    Bernard, D.6    Dickler, A.7    Nguyen, C.8
  • 9
    • 3142729105 scopus 로고    scopus 로고
    • Contrast effects on dosimetry of a partial breast irradiation system
    • DOI 10.1118/1.1763006
    • B. Kassas, F. Mourtada, J. L. Horton, and R. G. Lane, " Contrast effects on dosimetry of a partial breast irradiation system.," Med. Phys. 0094-2405 31, 1976-1979 (2004). 10.1118/1.1763006 (Pubitemid 38924817)
    • (2004) Medical Physics , vol.31 , Issue.7 , pp. 1976-1979
    • Kassas, B.1    Mourtada, F.2    Horton, J.L.3    Lane, R.G.4
  • 10
    • 22544453284 scopus 로고    scopus 로고
    • Dose perturbations due to contrast medium and air in MammoSite® treatment: An experimental and Monte Carlo study
    • DOI 10.1118/1.1943827
    • C. -W. Cheng, R. Mitra, X. A. Li, and I. J. Das, " Dose perturbation due to contrast medium and air in MammoSite treatment: An experimental and Monte Carlo study.," Med. Phys. 0094-2405 32, 2279-2287 (2005). 10.1118/1.1943827 (Pubitemid 41023186)
    • (2005) Medical Physics , vol.32 , Issue.7 , pp. 2279-2287
    • Cheng, C.-W.1    Mitra, R.2    Li, X.A.3    Das, I.J.4
  • 11
    • 38049151236 scopus 로고    scopus 로고
    • Three-dimensional quantitative dose reduction analysis in MammoSite balloon by Monte Carlo calculations
    • 1526-9914,. 10.1120/jacmv8i4.2669
    • Z. Zhang, E. I. Parsal, and J. J. Feldmeier, " Three-dimensional quantitative dose reduction analysis in MammoSite balloon by Monte Carlo calculations.," J. Appl. Clin. Med. Phys. 1526-9914 8, 139-151 (2007). 10.1120/jacmp.v8i4.2669
    • (2007) J. Appl. Clin. Med. Phys. , vol.8 , pp. 139-151
    • Zhang, Z.1    Parsal, E.I.2    Feldmeier, J.J.3
  • 12
    • 0035915799 scopus 로고    scopus 로고
    • Quality control in interstitial brachytherapy of the breast using pulsed dose rate: Treatment planning and dose delivery with an Ir-192 afterloading system
    • DOI 10.1016/S0167-8140(00)00270-X, PII S016781400000270X
    • C. A. Mangold, A. Rijnders, D. Georg, E. V. Limbergen, R. Pötter, and D. Huyskens, " Quality control in interstitial brachytherapy of the breast using pulsed dose rate: Treatment planning and dose delivery with and Ir-192 afterloading system.," Radiother. Oncol. 0167-8140 58, 43-51 (2001). 10.1016/S0167-8140(00)00270-X (Pubitemid 32124793)
    • (2001) Radiotherapy and Oncology , vol.58 , Issue.1 , pp. 43-51
    • Mangold, C.A.1    Rijnders, A.2    Georg, D.3    Van Limbergen, E.4    Potter, R.5    Huyskens, D.6
  • 13
    • 4544372255 scopus 로고    scopus 로고
    • Dose errors due to inhomogeneities in balloon catheter brachytherapy for breast cancer
    • 0360-3016,. 10.1016/j.ijrob2004.05.039
    • S. Ye, I. A. Brezovich, S. Shen, and S. Kim, " Dose errors due to inhomogeneities in balloon catheter brachytherapy for breast cancer.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 60, 672-677 (2004). 10.1016/j.ijrobp.2004.05.039
    • (2004) Int. J. Radiat. Oncol., Biol., Phys. , vol.60 , pp. 672-677
    • Ye, S.1    Brezovich, I.A.2    Shen, S.3    Kim, S.4
  • 14
    • 16344379083 scopus 로고    scopus 로고
    • The effect of finite patient dimensions and tissue inhomogeneities on dosimetry planning of 192Ir HDR breast brachytherapy: A Monte Carlo dose verification study
    • 0360-3016,. 10.1016/j.ijrob2004.12.065
    • E. Pantelis, " The effect of finite patient dimensions and tissue inhomogeneities on dosimetry planning of 192Ir HDR breast brachytherapy: A Monte Carlo dose verification study.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 61, 1596-1602 (2005). 10.1016/j.ijrobp.2004.12.065
    • (2005) Int. J. Radiat. Oncol., Biol., Phys. , vol.61 , pp. 1596-1602
    • Pantelis, E.1
  • 15
    • 33845298829 scopus 로고    scopus 로고
    • Dose modification factors for 192Ir high-dose-rate irradiation using Monte Carlo simulation
    • 1526-9914,. 10.1120/jacmv7i3.2293
    • B. Kassas, " Dose modification factors for 192Ir high-dose-rate irradiation using Monte Carlo simulation.," J. Appl. Clin. Med. Phys. 1526-9914 7, 28-34 (2006). 10.1120/jacmp.v7i3.2293
    • (2006) J. Appl. Clin. Med. Phys. , vol.7 , pp. 28-34
    • Kassas, B.1
  • 16
    • 33744821401 scopus 로고    scopus 로고
    • 192Ir HDR brachytherapy source in water using MOSFET detectors
    • DOI 10.1118/1.2198168
    • V. O. Zilio, O. P. Joneja, Y. Popowski, A. Rosenfeld, and R. Chawla, " Absolute depth-dose-rate measurements for an I 192 r HDR brachytherapy source in water using MOSFET detectors.," Med. Phys. 0094-2405 33, 1532-1539 (2006). 10.1118/1.2198168 (Pubitemid 43830241)
    • (2006) Medical Physics , vol.33 , Issue.6 , pp. 1532-1539
    • Zilio, V.O.1    Joneja, O.P.2    Popowski, Y.3    Rosenfeld, A.4    Chawla, R.5
  • 17
    • 0031441616 scopus 로고    scopus 로고
    • The response of a MOSFET, p-type semiconductor and LiF TLD to quasi- monoenergetic x-rays
    • DOI 10.1088/0031-9155/42/12/006, PII S0031915597861945
    • C. R. Edwards, S. Green, J. E. Palethorpe, and P. J. Mountford, " The response of a MOSFET, p-type semiconductor and LiF TLD to quasi-monoenergetic x-rays.," Phys. Med. Biol. 0031-9155 42, 2383-2391 (1997). 10.1088/0031-9155/42/12/006 (Pubitemid 28015563)
    • (1997) Physics in Medicine and Biology , vol.42 , Issue.12 , pp. 2383-2391
    • Edwards, C.R.1    Green, S.2    Palethorpe, J.E.3    Mountford, P.J.4
  • 20
    • 63649122639 scopus 로고    scopus 로고
    • Monte Carlo-derived TLD cross-calibration factors for treatment verification and measurement of skin dose in accelerated partial breast irradiation
    • 0031-9155,. 10.1088/0031-9155/54/6/015
    • H. M. Garnica-Garza, " Monte Carlo-derived TLD cross-calibration factors for treatment verification and measurement of skin dose in accelerated partial breast irradiation.," Phys. Med. Biol. 0031-9155 54, 1621-1631 (2009). 10.1088/0031-9155/54/6/015
    • (2009) Phys. Med. Biol. , vol.54 , pp. 1621-1631
    • Garnica-Garza, H.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.