Volumn 33, Issue 6, 2006, Pages 1532-1539

Absolute depth-dose-rate measurements for an 192Ir HDR brachytherapy source in water using MOSFET detectors

Author keywords

192Ir source; Absolute dosimetry; Brachytherapy; Monte Carlo; MOSFET

Indexed keywords

DOSIMETRY; MOSFET DEVICES; ONCOLOGY; RADIATION DECONTAMINATION; RADIOTHERAPY; SENSITIVITY ANALYSIS; THRESHOLD VOLTAGE;

EID: 33744821401     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2198168     Document Type: Article
Times cited : (44)

References (23)
  • 1
    • 4644290318 scopus 로고    scopus 로고
    • An implantable radiation dosimeter for use in external beam radiation therapy
    • C. W. Scarantino, D. M. Ruslander, C. J. Rini, G. G. Mann, H. T. Nagle, and R. D. Black, " An implantable radiation dosimeter for use in external beam radiation therapy., " Med. Phys. 31, 2658-2671 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 2658-2671
    • Scarantino, C.W.1    Ruslander, D.M.2    Rini, C.J.3    Mann, G.G.4    Nagle, H.T.5    Black, R.D.6
  • 2
    • 0035990040 scopus 로고    scopus 로고
    • Investigation of the use of MOSFET for clinical IMRT dosimetric verification
    • C. F. Chuang, L. J. Verhey, and P. Xia, " Investigation of the use of MOSFET for clinical IMRT dosimetric verification., " Med. Phys. 29, 1109-1115 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 1109-1115
    • Chuang, C.F.1    Verhey, L.J.2    Xia, P.3
  • 3
    • 4644311758 scopus 로고    scopus 로고
    • Comparison study of MOSFET detectors and diodes for entrance in vivo dosimetry in 18 MV x-ray beams
    • N. Jornet, P. Carrasco, D. Jurado, A. Ruiz, T. Eudaldo, and M. Ribas, " Comparison study of MOSFET detectors and diodes for entrance in vivo dosimetry in 18 MV x-ray beams., " Med. Phys. 31, 2534-2542 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 2534-2542
    • Jornet, N.1    Carrasco, P.2    Jurado, D.3    Ruiz, A.4    Eudaldo, T.5    Ribas, M.6
  • 4
    • 0031899494 scopus 로고    scopus 로고
    • Calibration of a MOSFET detection system for 6 MV in vivo dosimetry
    • P. Scalchi and P. Francescon, " Calibration of a MOSFET detection system for 6 MV in vivo dosimetry., " Int. J. Radiat. Oncol., Biol., Phys. 40, 987-993 (1998).
    • (1998) Int. J. Radiat. Oncol., Biol., Phys. , vol.40 , pp. 987-993
    • Scalchi, P.1    Francescon, P.2
  • 5
    • 4544233994 scopus 로고    scopus 로고
    • Performance characteristics of a microMOSFET as an in vivo dosimeter in radiation therapy
    • R. Ramaseshan, K. S. Kholi, T. J. Zang, T. Lam, B. Norlinger, A. Hallil, and M. Islam, " Performance characteristics of a microMOSFET as an in vivo dosimeter in radiation therapy., " Phys. Med. Biol. 49, 4031-4048 (2004).
    • (2004) Phys. Med. Biol. , vol.49 , pp. 4031-4048
    • Ramaseshan, R.1    Kholi, K.S.2    Zang, T.J.3    Lam, T.4    Norlinger, B.5    Hallil, A.6    Islam, M.7
  • 6
    • 1642393118 scopus 로고    scopus 로고
    • Characteristics and performance of a micro-MOSFET: An 'imageable' dosimeter for image-guided radiotherapy
    • C. G. Rowbottom and D. A. Jaffray, " Characteristics and performance of a micro-MOSFET: An 'imageable' dosimeter for image-guided radiotherapy., " Med. Phys. 31, 609-615 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 609-615
    • Rowbottom, C.G.1    Jaffray, D.A.2
  • 8
    • 0033013459 scopus 로고    scopus 로고
    • Evaluation of a MOSFET radiation sensor for the measurement of entrance surface dose in diagonistic radiology
    • D. J. Peet and M. D. Pryor, " Evaluation of a MOSFET radiation sensor for the measurement of entrance surface dose in diagonistic radiology., " Br. J. Radiol. 75, 562-568 (1999).
    • (1999) Br. J. Radiol. , vol.75 , pp. 562-568
    • Peet, D.J.1    Pryor, M.D.2
  • 12
    • 0033853810 scopus 로고    scopus 로고
    • Measurement of radiotherapy X-ray skin dose on chest wall phantom
    • A. K. Quanch, J. Morales, A. B. Rosenfeld, and P. Metcalfe, " Measurement of radiotherapy X-ray skin dose on chest wall phantom., " Med. Phys. 27 (7), 1676-1680 (2000).
    • (2000) Med. Phys. , vol.27 , Issue.7 , pp. 1676-1680
    • Quanch, A.K.1    Morales, J.2    Rosenfeld, A.B.3    Metcalfe, P.4
  • 13
    • 0029038383 scopus 로고
    • Monte Carlo aided dosimetry of the microselectron pulsed and high dose-rate Ir192 sources
    • J. F. Williamson and Z. Li, " Monte Carlo aided dosimetry of the microselectron pulsed and high dose-rate Ir192 sources., " Med. Phys. 22 (6), 809-819 (1995).
    • (1995) Med. Phys. , vol.22 , Issue.6 , pp. 809-819
    • Williamson, J.F.1    Li, Z.2
  • 14
    • 10644255803 scopus 로고    scopus 로고
    • Dosimetric characterization of radioactive seeds employed in prostate cancer therapy
    • V. O. Zilio, O. P. Joneja, Y. Popowski, and R. Chawla, " Dosimetric characterization of radioactive seeds employed in prostate cancer therapy., " Brachytherapy 3, 201-214 (2004).
    • (2004) Brachytherapy , vol.3 , pp. 201-214
    • Zilio, V.O.1    Joneja, O.P.2    Popowski, Y.3    Chawla, R.4
  • 15
    • 0028213977 scopus 로고
    • Evaluation of a dual bias dual metal oxide-silicon semiconductor field effect transistor detector as radiation dosimeter
    • M. Soubra, J. Cygler, and G. Mackay, " Evaluation of a dual bias dual metal oxide-silicon semiconductor field effect transistor detector as radiation dosimeter., " Med. Phys. 21, 567-572 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 567-572
    • Soubra, M.1    Cygler, J.2    MacKay, G.3
  • 16
    • 3442897997 scopus 로고    scopus 로고
    • Effects of temperature variation on MOSFET dosimetry
    • T. Cheung, M. J. Butson, and P. K. N. Yu, " Effects of temperature variation on MOSFET dosimetry., " Phys. Med. Biol. 49, N191-N196 (2004).
    • (2004) Phys. Med. Biol. , vol.49
    • Cheung, T.1    Butson, M.J.2    Yu, P.K.N.3
  • 19
    • 0031441616 scopus 로고    scopus 로고
    • The response of a MOSFET, p -type semiconductor and LiF TLD to quasi-monoenergetic x-rays
    • C. R. Edwards, S. Green, J. E. Palethorpe, and P. J. Mountford, " The response of a MOSFET, p -type semiconductor and LiF TLD to quasi-monoenergetic x-rays., " Phys. Med. Biol. 42, 2383-2391 (1997).
    • (1997) Phys. Med. Biol. , vol.42 , pp. 2383-2391
    • Edwards, C.R.1    Green, S.2    Palethorpe, J.E.3    Mountford, P.J.4
  • 21
    • 2442646488 scopus 로고    scopus 로고
    • Monte Carlo modelling of a High-Sensitivity MOSFET dosimeter for low- and medium-energy photon sources
    • B. Wang, C.-H. Kim, and X. G. Xu, " Monte Carlo modelling of a High-Sensitivity MOSFET dosimeter for low- and medium-energy photon sources., " Med. Phys. 31, 1003-1008 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 1003-1008
    • Wang, B.1    Kim, C.-H.2    Xu, X.G.3
  • 22
    • 0019655853 scopus 로고
    • Effect of photon energy on the response of MOSFET devices
    • C. M. Dozier and D. B. Brown, " Effect of photon energy on the response of MOSFET devices., " IEEE Trans. Nucl. Sci. 28 (6), 4137-4141 (1981).
    • (1981) IEEE Trans. Nucl. Sci. , vol.28 , Issue.6 , pp. 4137-4141
    • Dozier, C.M.1    Brown, D.B.2
  • 23
    • 0020288667 scopus 로고
    • Dose enhancement effect in semiconductor devices
    • D. M. Long, D. G. Millward, and J. Walace, " Dose enhancement effect in semiconductor devices., " IEEE Trans. Nucl. Sci. 29 (6), 1980-1984 (1982).
    • (1982) IEEE Trans. Nucl. Sci. , vol.29 , Issue.6 , pp. 1980-1984
    • Long, D.M.1    Millward, D.G.2    Walace, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.