메뉴 건너뛰기




Volumn 7, Issue 3, 2006, Pages 28-34

Dose modification factors for 192Ir high-dose-rate irradiation using Monte Carlo simulations

Author keywords

Brachytherapy; HDR; MammoSite; Monte Carlo; Partial breast irradiation

Indexed keywords


EID: 33845298829     PISSN: None     EISSN: 15269914     Source Type: Journal    
DOI: 10.1120/jacmp.v7i3.2293     Document Type: Article
Times cited : (13)

References (19)
  • 1
    • 0037296982 scopus 로고    scopus 로고
    • Initial clinical experience with the MammoSite breast brachytherapy applicator in women with early-stage breast cancer treated with breast-conserving therapy
    • Keisch M, Vicini FA, Kuske RR, et al. Initial clinical experience with the MammoSite breast brachytherapy applicator in women with early-stage breast cancer treated with breast-conserving therapy. Int J Radiat Oncol Biol Phys. 2003;55:289-293.
    • (2003) Int J Radiat Oncol Biol Phys , vol.55 , pp. 289-293
    • Keisch, M.1    Vicini, F.A.2    Kuske, R.R.3
  • 2
    • 3142665109 scopus 로고    scopus 로고
    • Two-year outcome with the MammoSite breast brachytherapy applicator: Factors associated with optimal cosmetic results when performing partial breast irradiation
    • Keisch M, Vicini FA, Kuske RR, et al. Two-year outcome with the MammoSite breast brachytherapy applicator: Factors associated with optimal cosmetic results when performing partial breast irradiation. Int J Radiat Oncol Biol Phys. 2003;57:S315.
    • (2003) Int J Radiat Oncol Biol Phys , vol.57
    • Keisch, M.1    Vicini, F.A.2    Kuske, R.R.3
  • 3
    • 12944259304 scopus 로고    scopus 로고
    • Thirty month results with MammoSite breast brachytherapy applicator: Cosmesis, toxicity, and local control in partial breast irradiation
    • Keisch M, Vicini FA, Scroggins T, et al. Thirty month results with MammoSite breast brachytherapy applicator: Cosmesis, toxicity, and local control in partial breast irradiation. Int J Radiat Oncol Biol Phys. 2004;60:S272.
    • (2004) Int J Radiat Oncol Biol Phys , vol.60
    • Keisch, M.1    Vicini, F.A.2    Scroggins, T.3
  • 4
    • 0041625984 scopus 로고    scopus 로고
    • Advances in brachytherapy: New approaches to target breast cancer
    • Hogle WP, Quinn AE, Heron DE. Advances in brachytherapy: New approaches to target breast cancer. Clin J Oncol Nurs. 2003;7:324-328.
    • (2003) Clin J Oncol Nurs , vol.7 , pp. 324-328
    • Hogle, W.P.1    Quinn, A.E.2    Heron, D.E.3
  • 5
    • 0037085979 scopus 로고    scopus 로고
    • Dosimetric characteristics of the MammoSite RTS, a new breast brachytherapy applicator
    • Edmundson GK, Vicini FA, Chen PY, et al. Dosimetric characteristics of the MammoSite RTS, a new breast brachytherapy applicator. Int J Radiat Oncol Biol Phys. 2002;52:1132-1139.
    • (2002) Int J Radiat Oncol Biol Phys , vol.52 , pp. 1132-1139
    • Edmundson, G.K.1    Vicini, F.A.2    Chen, P.Y.3
  • 6
    • 3142729105 scopus 로고    scopus 로고
    • Contrast effects on dosimetry of a partial breast irradiation system
    • Kassas B, Mourtada F, Horton JL, Lane RG. Contrast effects on dosimetry of a partial breast irradiation system. Med Phys. 2004;31:176-179.
    • (2004) Med Phys , vol.31 , pp. 176-179
    • Kassas, B.1    Mourtada, F.2    Horton, J.L.3    Lane, R.G.4
  • 7
    • 0003982205 scopus 로고
    • Stopping powers for electrons and positrons. International Commission on Radiation Units and Measurements
    • No. 37, Bethesda, MD;
    • ICRU Report No. 37. Stopping powers for electrons and positrons. International Commission on Radiation Units and Measurements, Bethesda, MD; 1984.
    • (1984) ICRU Report
  • 8
    • 0012389524 scopus 로고
    • Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom
    • Pamphlet, New York: Society of Nuclear Medicine;
    • Snyder WS, Ford MR, Wagner GG, Fisher HL. Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom. Medical Internal Radiation Dose (MIRD) Pamphlet No. 5. New York: Society of Nuclear Medicine; 1969.
    • (1969) Medical Internal Radiation Dose (MIRD) , Issue.5
    • Snyder, W.S.1    Ford, M.R.2    Wagner, G.G.3    Fisher, H.L.4
  • 9
    • 0031739032 scopus 로고    scopus 로고
    • Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source
    • Daskalov GM, Loffler E, Williamson JF. Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source. Med Phys. 1998;25(11):2200-2208.
    • (1998) Med Phys , vol.25 , Issue.11 , pp. 2200-2208
    • Daskalov, G.M.1    Loffler, E.2    Williamson, J.F.3
  • 10
    • 85027225110 scopus 로고    scopus 로고
    • Kocher DC. Radioactive decay tables - A handbook of decay data for application to radiation dosimetry and radiological assessment. DOE/TIC 11026, US Department of Energy; 1981.
    • Kocher DC. Radioactive decay tables - A handbook of decay data for application to radiation dosimetry and radiological assessment. DOE/TIC 11026, US Department of Energy; 1981.
  • 11
    • 0003883182 scopus 로고    scopus 로고
    • Version 2.4.0. Los Alamos National Laboratory, Los Alamos, NM;
    • Waters LS. MCNPX User's Manual Version 2.4.0. Los Alamos National Laboratory, Los Alamos, NM; 2002.
    • (2002) MCNPX User's Manual
    • Waters, L.S.1
  • 12
    • 0029062568 scopus 로고
    • Experimental validation of Monte Carlo dose calculations about a high-intensity Ir-192 source for pulsed dose-rate brachytherapy
    • Valicenti RK, Kirov AS, Meigooni AS, et al. Experimental validation of Monte Carlo dose calculations about a high-intensity Ir-192 source for pulsed dose-rate brachytherapy. Med Phys. 1995;22(6):821-829.
    • (1995) Med Phys , vol.22 , Issue.6 , pp. 821-829
    • Valicenti, R.K.1    Kirov, A.S.2    Meigooni, A.S.3
  • 13
    • 34548208569 scopus 로고    scopus 로고
    • Dose non-uniformity on the prescription surface and skin-balloon separation implications for balloon catheter brachytherapy for breast cancer
    • Ye S, Ove R, Kim S, Shen S, Dunan J, Brezovich IA. Dose non-uniformity on the prescription surface and skin-balloon separation implications for balloon catheter brachytherapy for breast cancer. Med Phys. 2004;31:1745.
    • (2004) Med Phys , vol.31 , pp. 1745
    • Ye, S.1    Ove, R.2    Kim, S.3    Shen, S.4    Dunan, J.5    Brezovich, I.A.6
  • 15
    • 33847731028 scopus 로고    scopus 로고
    • Cosmetic outcome and incidence of infection with the Mammosite breast brachytherapy applicator
    • Dickler AT, Kirk MC, Choo J, et al. Cosmetic outcome and incidence of infection with the Mammosite breast brachytherapy applicator. Ent J Radiat Oncol Biol Phys. 2004;60:S398-S399.
    • (2004) Ent J Radiat Oncol Biol Phys , vol.60
    • Dickler, A.T.1    Kirk, M.C.2    Choo, J.3
  • 16
    • 0028230872 scopus 로고
    • Comprehensive QA for radiation oncology: Reportof AAPM Radiation Therapy Committee Task Group 40
    • Kutcher GJ, Coia L, Gillin M, et al. Comprehensive QA for radiation oncology: Reportof AAPM Radiation Therapy Committee Task Group 40. Med Phys. 1994;21:581-618.
    • (1994) Med Phys , vol.21 , pp. 581-618
    • Kutcher, G.J.1    Coia, L.2    Gillin, M.3
  • 17
    • 22544453284 scopus 로고    scopus 로고
    • Dose perturbations due to contrast medium and air in MammoSite treatment: An experimental and Monte Carlo study
    • Cheng CW, Mitra R, Lee XA, Das IJ. Dose perturbations due to contrast medium and air in MammoSite treatment: An experimental and Monte Carlo study. Med Phys. 2005;32(7):2279-2287.
    • (2005) Med Phys , vol.32 , Issue.7 , pp. 2279-2287
    • Cheng, C.W.1    Mitra, R.2    Lee, X.A.3    Das, I.J.4
  • 18
    • 2442641529 scopus 로고    scopus 로고
    • Dose perturbation induced by radiographic contrast inside brachytherapy balloon
    • Kirk MC, Hsi WC, Chu J, Niu H, Hu Z. Dose perturbation induced by radiographic contrast inside brachytherapy balloon. Med Phys. 2004;31:1219-1224.
    • (2004) Med Phys , vol.31 , pp. 1219-1224
    • Kirk, M.C.1    Hsi, W.C.2    Chu, J.3    Niu, H.4    Hu, Z.5
  • 19
    • 0344395055 scopus 로고    scopus 로고
    • Partial breast irradiation: Is it ready for prime time?
    • Buchholz TA. Partial breast irradiation: Is it ready for prime time? Int J Radiat Oncol Biol Phys. 2003;57:1214-1216.
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , pp. 1214-1216
    • Buchholz, T.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.