메뉴 건너뛰기




Volumn 62, Issue 3, 2009, Pages 829-834

Interleaved spiral-in/out with application to functional MRI (fMRI)

Author keywords

Functional magnetic resonance imaging; Signal pile up; Spiral in out methods; Susceptibility artifacts; UNFOLD

Indexed keywords

BIOMEDICAL SIGNAL PROCESSING; BRAIN; CHEMICAL ACTIVATION; MAGNETIC RESONANCE IMAGING; PILES;

EID: 69449105711     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22056     Document Type: Article
Times cited : (20)

References (26)
  • 1
    • 0347595449 scopus 로고    scopus 로고
    • EPI-BOLD fMRI of Human Motor Cortex at 1.5 T and 3.0 T: Sensitivity Dependence on Echo Time and Acquisition Bandwidth
    • DOI 10.1002/jmri.10440
    • Fera F, Yongbi MN, Gelderen P, Frank JA, Mattay VS, Duyn J. EPI-BOLD fMRI of human motor cortex at 1.5 T and 3.0 T: sensitivity dependence on echo time and acquisition bandwidth. J Magn Reson Imaging 2003;19:19-26. (Pubitemid 38055725)
    • (2004) Journal of Magnetic Resonance Imaging , vol.19 , Issue.1 , pp. 19-26
    • Fera, F.1    Yongbi, M.N.2    Van Gelderen, P.3    Frank, J.A.4    Mattay, V.S.5    Duyn, J.H.6
  • 2
    • 12844281923 scopus 로고    scopus 로고
    • Mitigation of susceptibility-induced signal loss in neuroimaging using localized shim coils
    • Hsu JJ, Glover GH. Mitigation of susceptibility-induced signal loss in neuroimaging using localized shim coils. Magn Reson Med 2005;53:243-248.
    • (2005) Magn Reson Med , vol.53 , pp. 243-248
    • Hsu, J.J.1    Glover, G.H.2
  • 3
    • 0242385450 scopus 로고    scopus 로고
    • Utilization of an Intra-Oral Diamagnetic Passive Shim in Functional MRI of the Inferior Frontal Cortex
    • DOI 10.1002/mrm.10626
    • Wilson JL, Jezzard P. Utilization of an intra-oral diamagnetic passive shim in functional MRI of the inferior frontal cortex. Magn Reson Med 2003;50:1089-1094. (Pubitemid 37356589)
    • (2003) Magnetic Resonance in Medicine , vol.50 , Issue.5 , pp. 1089-1094
    • Wilson, J.L.1    Jezzard, P.2
  • 5
    • 0026500406 scopus 로고
    • Reduction of susceptibility artifact in gradient-echo imaging
    • Cho ZH, Ro YM. Reduction of susceptibility artifact in gradient-echo imaging. Magn Reson Med 1992;23:193-200.
    • (1992) Magn Reson Med , vol.23 , pp. 193-200
    • Cho, Z.H.1    Ro, Y.M.2
  • 6
    • 0034529949 scopus 로고    scopus 로고
    • Compensation of susceptibility-induced signal loss in echo-planar imaging for functional applications
    • DOI 10.1016/S0730-725X(00)00199-5, PII S0730725X00001995
    • Cordes D, Turski PA, Sorenson JA. Compensation of susceptibility-induced signal loss in echo-planar imaging for functional applications. Magn Reson Imaging 2000;18:1055. (Pubitemid 32002706)
    • (2000) Magnetic Resonance Imaging , vol.18 , Issue.9 , pp. 1055-1068
    • Cordes, D.1    Turski, P.A.2    Sorenson, J.A.3
  • 7
    • 0032868199 scopus 로고    scopus 로고
    • 3D Z-shim method for reduction of susceptibility effects in BOLD fMRI
    • Glover GH. 3D Z-shim method for reduction of susceptibility effects in BOLD fMRI. Magn Reson Med 1999;42:290-299.
    • (1999) Magn Reson Med , vol.42 , pp. 290-299
    • Glover, G.H.1
  • 8
    • 0036432616 scopus 로고    scopus 로고
    • Single-shot interleaved z-shim EPI with optimized compensation for signal losses due to susceptibility-induced field inhomogeneity at 3 T
    • DOI 10.1006/nimg.2002.1274
    • Gu H, Feng H, Zhan W, Xu S, Silbersweig DA, Stern E, Yang Y. Single-shot interleaved Z-shim EPI with optimized compensation for signal losses due to susceptibility-induced field inhomogeneity at 3 T. Neuroimage 2002;17:1358. (Pubitemid 35333856)
    • (2002) NeuroImage , vol.17 , Issue.3 , pp. 1358-1364
    • Gu, H.1    Feng, H.2    Zhan, W.3    Xu, S.4    Silbersweig, D.A.5    Stern, E.6    Yang, Y.7
  • 9
    • 0034839919 scopus 로고    scopus 로고
    • Spiral-in/out BOLD fMRI for increased SNR and reduced susceptibility artifacts
    • Glover GH, Law CS. Spiral-in/out BOLD fMRI for increased SNR and reduced susceptibility artifacts. Magn Reson Med 2001;46:515-522.
    • (2001) Magn Reson Med , vol.46 , pp. 515-522
    • Glover, G.H.1    Law, C.S.2
  • 10
    • 0036328933 scopus 로고    scopus 로고
    • Compensation of susceptibility-induced bold sensitivity losses in echo-planar fMRI imaging
    • DOI 10.1006/nimg.2001.0985
    • Deichmann R, Josephs O, Hutton C, Corfield DR, Turner R. Compensation of susceptibility-induced BOLD sensitivity losses in echo-planar fMRI imaging. Neuroimage 2002;15:120. (Pubitemid 34852211)
    • (2002) NeuroImage , vol.15 , Issue.1 , pp. 120-135
    • Deichmann, R.1    Josephs, O.2    Hutton, C.3    Corfield, D.R.4    Turner, R.5
  • 11
    • 0034894659 scopus 로고    scopus 로고
    • Single-shot EPI with signal recovery from the susceptibility-induced losses
    • Song AW. Single-shot EPI with signal recovery from the susceptibility-induced losses. Magn Reson Med 2001;46:407-411.
    • (2001) Magn Reson Med , vol.46 , pp. 407-411
    • Song, A.W.1
  • 12
    • 0028904705 scopus 로고
    • A velocity k-space analysis of flow effects in echo-planar and spiral imaging
    • Nishimura DG, Irarrazabal P, Meyer CH. A velocity k-space analysis of flow effects in echo-planar and spiral imaging. Magn Reson Med 1995;33:549-556.
    • (1995) Magn Reson Med , vol.33 , pp. 549-556
    • Nishimura, D.G.1    Irarrazabal, P.2    Meyer, C.H.3
  • 13
    • 0032751897 scopus 로고    scopus 로고
    • Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI
    • DOI 10.1002/(SICI)1522-2594(199911)42:5<813::AID-MRM1>3.0.CO;2-S
    • Madore B, Glover GH, Pelc NJ. Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI. Magn Reson Med 1999;42:813-828. (Pubitemid 29521471)
    • (1999) Magnetic Resonance in Medicine , vol.42 , Issue.5 , pp. 813-828
    • Madore, B.1    Glover, G.H.2    Pelc, N.J.3
  • 14
    • 0036708129 scopus 로고    scopus 로고
    • Using UNFOLD to remove artifacts in parallel imaging and in partial-fourier imaging
    • DOI 10.1002/mrm.10229
    • Madore B. Using UNFOLD to remove artifacts in parallel imaging and in partial-Fourier imaging. Magn Reson Med 2002;48:493-501. (Pubitemid 34951327)
    • (2002) Magnetic Resonance in Medicine , vol.48 , Issue.3 , pp. 493-501
    • Madore, B.1
  • 15
    • 1842481349 scopus 로고    scopus 로고
    • Improved Combination of Spiral-In/Out Images for BOLD fMRI
    • DOI 10.1002/mrm.20016
    • Glover GH, Thomason ME. Improved combination of spiral-in/out images for BOLD fMRI. Magn Reson Med 2004;51:863-868. (Pubitemid 38420466)
    • (2004) Magnetic Resonance in Medicine , vol.51 , Issue.4 , pp. 863-868
    • Glover, G.H.1    Thomason, M.E.2
  • 17
    • 0029044039 scopus 로고
    • Discrimination of large venous vessels in time-course spiral blood oxygen dependent magnetic resonance functional neuroimaging
    • Lee AT, Glover GH. Discrimination of large venous vessels in time-course spiral blood oxygen dependent magnetic resonance functional neuroimaging. Magn Reson Med 1995;33:745-754.
    • (1995) Magn Reson Med , vol.33 , pp. 745-754
    • Lee, A.T.1    Glover, G.H.2
  • 18
    • 0032776471 scopus 로고    scopus 로고
    • Deconvolution of impulse response in event-related BOLD fMRI
    • Glover GH. Deconvolution of impulse response in event-related BOLD fMRI. Neuroimage 1999;9:416-429.
    • (1999) Neuroimage , vol.9 , pp. 416-429
    • Glover, G.H.1
  • 19
    • 0029096148 scopus 로고
    • Analysis of fMRI time-series revisited - again
    • Comment
    • Worsley KJ, Friston KJ. Analysis of fMRI time-series revisited - again [Comment]. Neuroimage 1995;2:173-181.
    • (1995) Neuroimage , vol.2 , pp. 173-181
    • Worsley, K.J.1    Friston, K.J.2
  • 20
    • 0036522413 scopus 로고    scopus 로고
    • Estimating the effective degrees of freedom in univariate multiple regression analysis
    • DOI 10.1016/S1361-8415(01)00052-4, PII S1361841501000524
    • Kruggel F, Pelegrini-Issac M, Benali H. Estimating the effective degrees of freedom in univariate multiple regression analysis. Med Image Anal 2002;6:63-75. (Pubitemid 35282818)
    • (2002) Medical Image Analysis , vol.6 , Issue.1 , pp. 63-75
    • Kruggel, F.1    Pelegrini-Issac, M.2    Benali, H.3
  • 21
    • 0031932352 scopus 로고    scopus 로고
    • Self-navigated spiral fMRI: Interleaved versus single-shot
    • DOI 10.1002/mrm.1910390305
    • Glover GH, Lai S. Self-navigated spiral fMRI: interleaved versus single-shot. Magn Reson Med 1998;39:361-368. (Pubitemid 28128378)
    • (1998) Magnetic Resonance in Medicine , vol.39 , Issue.3 , pp. 361-368
    • Glover, G.H.1    Lai, S.2
  • 23
    • 34547879249 scopus 로고    scopus 로고
    • Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters
    • DOI 10.1002/jmri.20969
    • Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO. Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters. J Magn Reson Imaging 2007;26:375-385. (Pubitemid 47257737)
    • (2007) Journal of Magnetic Resonance Imaging , vol.26 , Issue.2 , pp. 375-385
    • Dietrich, O.1    Raya, J.G.2    Reeder, S.B.3    Reiser, M.F.4    Schoenberg, S.O.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.