메뉴 건너뛰기




Volumn 52, Issue 3, 2004, Pages 688-692

Self-calibrated spiral SENSE

Author keywords

Optimal radius; Self calibration; SENSE; Spiral trajectory; Undersampling

Indexed keywords

OPTICAL TRANSFER FUNCTION;

EID: 4243134902     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20197     Document Type: Article
Times cited : (28)

References (18)
  • 3
    • 0036137464 scopus 로고    scopus 로고
    • Recent advances in image reconstruction, coil sensitivity calibration, and coil array design for SMASH and generalized parallel MRI
    • Sodickson DK, McKenzie CA, Ohliger MA, Yeh EN, Price MD. Recent advances in image reconstruction, coil sensitivity calibration, and coil array design for SMASH and generalized parallel MRI. MAGMA 2002;13:158-163.
    • (2002) MAGMA , vol.13 , pp. 158-163
    • Sodickson, D.K.1    McKenzie, C.A.2    Ohliger, M.A.3    Yeh, E.N.4    Price, M.D.5
  • 7
    • 0034878536 scopus 로고    scopus 로고
    • An investigation into the use of sensitivity-encoded techniques to increase temporal resolution in dynamic contrast-enhanced breast imaging
    • Larkman DJ, deSouza NM, Bydder M, Hainal JV. An investigation into the use of sensitivity-encoded techniques to increase temporal resolution in dynamic contrast-enhanced breast imaging. J Magn Reson Imaging 2001;14:329-335.
    • (2001) J Magn Reson Imaging , vol.14 , pp. 329-335
    • Larkman, D.J.1    DeSouza, N.M.2    Bydder, M.3    Hainal, J.V.4
  • 8
    • 0036187917 scopus 로고    scopus 로고
    • Combination of signals from array coils using image-based estimation of coil sensitivity profiles
    • Bydder M, Larkman DJ, Hainal JV. Combination of signals from array coils using image-based estimation of coil sensitivity profiles. Magn Reson Med 2002;47:539-548.
    • (2002) Magn Reson Med , vol.47 , pp. 539-548
    • Bydder, M.1    Larkman, D.J.2    Hainal, J.V.3
  • 9
    • 0033856106 scopus 로고    scopus 로고
    • Tailored SMASH image reconstructions for robust in vivo parallel MR imaging
    • Sodickson DK. Tailored SMASH image reconstructions for robust in vivo parallel MR imaging. Magn Reson Med 2000;44:243-251.
    • (2000) Magn Reson Med , vol.44 , pp. 243-251
    • Sodickson, D.K.1
  • 10
    • 0032425458 scopus 로고    scopus 로고
    • AUTO-SMASH: A self-calibrating technique for SMASH imaging. Simultaneous acquisition of spatial harmonics
    • Jakob PM, Griswold MA, Edelman RR, Sodickson DK. AUTO-SMASH: a self-calibrating technique for SMASH imaging. Simultaneous acquisition of spatial harmonics. MAGMA 1998;7:42-54.
    • (1998) MAGMA , vol.7 , pp. 42-54
    • Jakob, P.M.1    Griswold, M.A.2    Edelman, R.R.3    Sodickson, D.K.4
  • 15
    • 0034794323 scopus 로고    scopus 로고
    • Advances in sensitivity encoding with arbitrary k-space trajectories
    • Pruessmann KP, Weiger M, Bornert P, Boesiger P. Advances in sensitivity encoding with arbitrary k-space trajectories. Magn Reson Med 2001;46:638-651.
    • (2001) Magn Reson Med , vol.46 , pp. 638-651
    • Pruessmann, K.P.1    Weiger, M.2    Bornert, P.3    Boesiger, P.4
  • 16
    • 0031786484 scopus 로고    scopus 로고
    • Polar sampling in k-space: Reconstruction effects
    • Lauzon ML, Rutt BK. Polar sampling in k-space: reconstruction effects. Magn Reson Med 1998;40:769-782.
    • (1998) Magn Reson Med , vol.40 , pp. 769-782
    • Lauzon, M.L.1    Rutt, B.K.2
  • 17
    • 0032818760 scopus 로고    scopus 로고
    • Simple analytic spiral k-space algorithm
    • Glover GH. Simple analytic spiral k-space algorithm. Magn Reson Med 1999;42:412-415.
    • (1999) Magn Reson Med , vol.42 , pp. 412-415
    • Glover, G.H.1
  • 18
    • 0033812663 scopus 로고    scopus 로고
    • Description of parallel imaging in MRI using multiple coils
    • Wang Y. Description of parallel imaging in MRI using multiple coils. Magn Reson Med 2000;44:495-499.
    • (2000) Magn Reson Med , vol.44 , pp. 495-499
    • Wang, Y.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.