메뉴 건너뛰기




Volumn 43, Issue 1-2, 2009, Pages 19-33

New perfusion imaging of tissue transplants with Contrast Harmonic Ultrasound Imaging (CHI) and Magnetic Resonance Imaging (MRI) in comparison with laser-induced Indocyanine Green (ICG) fluorescence angiography

Author keywords

Contrast enhanced ultrasound; Free flaps; ICG fluorescence angiography; MRI; Tissue perfusion

Indexed keywords

INDOCYANINE GREEN; SONOVUE;

EID: 69449092987     PISSN: 13860291     EISSN: None     Source Type: Journal    
DOI: 10.3233/CH-2009-1218     Document Type: Article
Times cited : (27)

References (31)
  • 2
    • 0032978923 scopus 로고    scopus 로고
    • Efficacy of conventional monitoring techniques in free tissue transfer: An 11-year experience in 750 consecutive cases
    • J.J. Disa, P.G. Cordeiro and D.A. Hidalgo, Efficacy of conventional monitoring techniques in free tissue transfer: an 11-year experience in 750 consecutive cases, Plast. Reconstr. Surg. 104 (1999), 97-101.
    • (1999) Plast. Reconstr. Surg. , vol.104 , pp. 97-101
    • Disa, J.J.1    Cordeiro, P.G.2    Hidalgo, D.A.3
  • 3
    • 84944886203 scopus 로고
    • A tricarbocyanine dye for continuous recording of dilution curves in whole blood independent of variations in blood oxygen saturation
    • I.J. Fox, L.G. Brooker, D.W. Heseltine, H.E. Essex and E.H. Wood, A tricarbocyanine dye for continuous recording of dilution curves in whole blood independent of variations in blood oxygen saturation, Proc. Staff Meet. Mayo Clin. 32 (1957), 478-484.
    • (1957) Proc. Staff Meet. Mayo Clin. , vol.32 , pp. 478-484
    • Fox, I.J.1    Brooker, L.G.2    Heseltine, D.W.3    Essex, H.E.4    Wood, E.H.5
  • 4
    • 70449329284 scopus 로고
    • Indocyanine green: Physical and physiologic properties
    • I.J. Fox and E.H. Wood, Indocyanine green: physical and physiologic properties, Proc. Staff Meet. Mayo Clin. 35 (1960), 732-744.
    • (1960) Proc. Staff Meet. Mayo Clin. , vol.35 , pp. 732-744
    • Fox, I.J.1    Wood, E.H.2
  • 6
    • 33645318156 scopus 로고    scopus 로고
    • Color doppler ultrasonography is a reliable predictor of free tissue transfer outcomes in head and neck reconstruction
    • A.N. Khalid, S.A. Quraishi, W.A. Zang, J.L. Chadwick and B.C. Stack Jr., Color doppler ultrasonography is a reliable predictor of free tissue transfer outcomes in head and neck reconstruction, Otolaryngol. Head Neck Surg. 134 (2006), 635-638.
    • (2006) Otolaryngol. Head Neck Surg. , vol.134 , pp. 635-638
    • Khalid, A.N.1    Quraishi, S.A.2    Zang, W.A.3    Chadwick, J.L.4    Stack Jr., B.C.5
  • 7
    • 0031900329 scopus 로고    scopus 로고
    • The effect of an implantable Doppler probe on the salvage of microvascular tissue transplants
    • discussion 1274-11265
    • G.M. Kind, R.F. Buntic, G.M. Buncke, T.M. Cooper, P.P. Siko and H.J. Buncke Jr., The effect of an implantable Doppler probe on the salvage of microvascular tissue transplants, Plast. Reconstr. Surg. 101 (1998), 1268-1273, discussion 1274-11265
    • (1998) Plast. Reconstr. Surg. , vol.101 , pp. 1268-1273
    • Kind, G.M.1    Buntic, R.F.2    Buncke, G.M.3    Cooper, T.M.4    Siko, P.P.5    Buncke Jr., H.J.6
  • 8
    • 14944356360 scopus 로고    scopus 로고
    • The role of near-infrared angiography in the assessment of post-operative venous congestion in random pattern, pedicled island and free flaps
    • K.G. Krishnan, G. Schackert and R. Steinmeier, The role of near-infrared angiography in the assessment of post-operative venous congestion in random pattern, pedicled island and free flaps, Br. J. Plast. Surg. 58 (2005), 330-338.
    • (2005) Br. J. Plast. Surg. , vol.58 , pp. 330-338
    • Krishnan, K.G.1    Schackert, G.2    Steinmeier, R.3
  • 9
    • 9644291409 scopus 로고    scopus 로고
    • Indocyanine-green fluorescence video angiography used clinically to evaluate tissue perfusion in microsurgery
    • H. Mothes, T. Doenicke, R. Friedel, M. Simon, E. Markgraf and O. Bach, Indocyanine-green fluorescence video angiography used clinically to evaluate tissue perfusion in microsurgery, J. Trauma 57 (2004), 1018-1024.
    • (2004) J. Trauma , vol.57 , pp. 1018-1024
    • Mothes, H.1    Doenicke, T.2    Friedel, R.3    Simon, M.4    Markgraf, E.5    Bach, O.6
  • 10
    • 0019733001 scopus 로고
    • Transcutaneous PO2 monitoring for assessing viability and predicting survival of skin flaps: Experimental and clinical correlations
    • D. Serafin, C.B. Lesesne, R.Y. Mullen and N.G. Georgiade, Transcutaneous PO2 monitoring for assessing viability and predicting survival of skin flaps: experimental and clinical correlations, J. Microsurg. 2 (1981), 165-178.
    • (1981) J. Microsurg. , vol.2 , pp. 165-178
    • Serafin, D.1    Lesesne, C.B.2    Mullen, R.Y.3    Georgiade, N.G.4
  • 11
    • 0032054550 scopus 로고    scopus 로고
    • The use of near-infrared spectroscopy for assessing flap viability during reconstructive surgery
    • M.S. Thorniley, J.S. Sinclair, N.J. Barnett, C.B. Shurey and C.J. Green, The use of near-infrared spectroscopy for assessing flap viability during reconstructive surgery, Br. J. Plast. Surg. 51 (1998), 218-226.
    • (1998) Br. J. Plast. Surg. , vol.51 , pp. 218-226
    • Thorniley, M.S.1    Sinclair, J.S.2    Barnett, N.J.3    Shurey, C.B.4    Green, C.J.5
  • 12
    • 33645240821 scopus 로고    scopus 로고
    • Review of monitoring free muscle flap transfers in reconstructive surgery: Role of 99mTc sestamibi scintigraphy
    • H. Top, A. Sarikaya, A.C. Aygit, E. Benlier and M. Kiyak, Review of monitoring free muscle flap transfers in reconstructive surgery: role of 99mTc sestamibi scintigraphy, Nucl. Med. Commun. 27 (2006), 91-98.
    • (2006) Nucl. Med. Commun. , vol.27 , pp. 91-98
    • Top, H.1    Sarikaya, A.2    Aygit, A.C.3    Benlier, E.4    Kiyak, M.5
  • 15
    • 0036460692 scopus 로고    scopus 로고
    • Intraoperative evaluation of skin-flap viability using laser-induced fluorescence of indocyanine green
    • DOI 10.1054/bjps.2002.3969
    • C. Holm, M. Mayr, E. Hoefter, A. Becker, U.J. Pfeiffer and W. Muehlbauer, Intraoperative evaluation of skin-flap viability using laser-induced fluorescence of indocyanine green, Br. J. Plast. Surg. 55 (2002), 635-644. (Pubitemid 35469785)
    • (2002) British Journal of Plastic Surgery , vol.55 , Issue.8 , pp. 635-644
    • Holm, C.1    Mayr, M.2    Hofter, E.3    Becker, A.4    Pfeiffer, U.J.5    Muhlbauer, W.6
  • 17
    • 33750358126 scopus 로고    scopus 로고
    • Calf muscles imaged at BOLD MR: Correlation with TcPO2 and flowmetry measurements during ischemia and reactive hyperemia - Initial experience
    • H.P. Ledermann, H.G. Heidecker, A.C. Schulte, C. Thalhammer, M. Aschwanden, K.A. Jaeger, K. Scheffler and D. Bilecen, Calf muscles imaged at BOLD MR: correlation with TcPO2 and flowmetry measurements during ischemia and reactive hyperemia - initial experience, Radiology 241 (2006), 477-484.
    • (2006) Radiology , vol.241 , pp. 477-484
    • Ledermann, H.P.1    Heidecker, H.G.2    Schulte, A.C.3    Thalhammer, C.4    Aschwanden, M.5    Jaeger, K.A.6    Scheffler, K.7    Bilecen, D.8
  • 18
    • 0029907308 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis
    • DOI 10.1002/mrm.1910360510
    • L. Ostergaard, R.M. Weisskoff, D.A. Chesler, C. Gyldensted and B.R. Rosen, High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis, Magn. Reson. Med. 36 (1996), 715-725. (Pubitemid 26376710)
    • (1996) Magnetic Resonance in Medicine , vol.36 , Issue.5 , pp. 715-725
    • Ostergaard, L.1    Weisskoff, R.M.2    Chesler, D.A.3    Gyldensted, G.4    Rosen, B.R.5
  • 19
    • 3042660881 scopus 로고    scopus 로고
    • Vascular flow and perfusion imaging with ultrasound contrast agents
    • DOI 10.1016/j.ultrasmedbio.2004.03.016, PII S0301562904001012
    • M. Bruce, M. Averkiou, K. Tiemann, S. Lohmaier, J. Powers and K. Beach, Vascular flow and perfusion imaging with ultrasound contrast agents, Ultrasound Med. Biol. 30 (2004), 735-743. (Pubitemid 38829539)
    • (2004) Ultrasound in Medicine and Biology , vol.30 , Issue.6 , pp. 735-743
    • Bruce, M.1    Averkiou, M.2    Tiemann, K.3    Lohmaier, S.4    Powers, J.5    Beach, K.6
  • 20
    • 9644272880 scopus 로고    scopus 로고
    • Multi-frequency harmonic arrays: Initial experience with a novel transducer concept for nonlinear contrast imaging
    • F. Forsberg, W.T. Shi, B. Jadidian and A.A. Winder, Multi-frequency harmonic arrays: initial experience with a novel transducer concept for nonlinear contrast imaging, Ultrasonics 43 (2004), 79-85.
    • (2004) Ultrasonics , vol.43 , pp. 79-85
    • Forsberg, F.1    Shi, W.T.2    Jadidian, B.3    Winder, A.A.4
  • 22
    • 21744458729 scopus 로고    scopus 로고
    • Vaskuläre bildgebung mittels kontrastverstärkter sonographie in der experimentellen anwendung
    • DOI 10.1007/s00117-005-1186-1
    • M. Krix, H.U. Kauczor and S. Delorme, Vascular imaging with contrast-enhanced sonography for experimental use, Radiologe 45 (2005), 552-559. (Pubitemid 40941789)
    • (2005) Radiologe , vol.45 , Issue.6 , pp. 552-559
    • Krix, M.1    Kauczor, H.-U.2    Delorme, S.3
  • 23
    • 1642317459 scopus 로고    scopus 로고
    • Low mechanical index contrast-enhanced ultrasound better reflects high arterial perfusion of liver metastases than arterial phase computed tomography
    • M. Krix, F. Kiessling, M. Essig, F. Herth, A. Karcher, M. Le-Huu, H.U. Kauczor and S. Delorme, Low mechanical index contrast-enhanced ultrasound better reflects high arterial perfusion of liver metastases than arterial phase computed tomography, Invest. Radiol. 39 (2004), 216-222.
    • (2004) Invest. Radiol. , vol.39 , pp. 216-222
    • Krix, M.1    Kiessling, F.2    Essig, M.3    Herth, F.4    Karcher, A.5    Le-Huu, M.6    Kauczor, H.U.7    Delorme, S.8
  • 25
    • 0042844541 scopus 로고    scopus 로고
    • Blood flow quantification with contrast-enhanced US: "entrance in the section" phenomenon-phantom and rabbit study
    • O. Lucidarme, S. Franchi-Abella, J.M. Correas, S.L. Bridal, E. Kurtisovski and G. Berger, Blood flow quantification with contrast-enhanced US: "entrance in the section" phenomenon-phantom and rabbit study, Radiology 228 (2003), 473-479.
    • (2003) Radiology , vol.228 , pp. 473-479
    • Lucidarme, O.1    Franchi-Abella, S.2    Correas, J.M.3    Bridal, S.L.4    Kurtisovski, E.5    Berger, G.6
  • 26
    • 47849122288 scopus 로고    scopus 로고
    • Evaluation of microcirculation of free flaps of the lower leg by contrast harmonic imaging (CHI) with time intensity curve (TIC) analysis
    • L. Prantl, S. Schreml, M. Walter, P. Kasprzak, A. Stehr, M. Nerlich, S. Feuerbach and E.M. Jung, Evaluation of microcirculation of free flaps of the lower leg by contrast harmonic imaging (CHI) with time intensity curve (TIC) analysis, Clin. Hemorheol. Microcirc. 39 (2008), 343-350.
    • (2008) Clin. Hemorheol. Microcirc. , vol.39 , pp. 343-350
    • Prantl, L.1    Schreml, S.2    Walter, M.3    Kasprzak, P.4    Stehr, A.5    Nerlich, M.6    Feuerbach, S.7    Jung, E.M.8
  • 29
    • 34648830329 scopus 로고    scopus 로고
    • Quantitative evaluation of muscle perfusion with CEUS and with MR
    • M.A. Weber, M. Krix and S. Delorme, Quantitative evaluation of muscle perfusion with CEUS and with MR, Eur. Radiol. 17 (2007), 2663-2674.
    • (2007) Eur. Radiol. , vol.17 , pp. 2663-2674
    • Weber, M.A.1    Krix, M.2    Delorme, S.3
  • 30
    • 0242557653 scopus 로고    scopus 로고
    • Moderne sonographische methoden zur quantifizierung von gewebeperfusion
    • DOI 10.1007/s00117-003-0958-8
    • M. Krix, H.U. Kauczor and S. Delorme, Quantification of tissue perfusion with novel ultrasound methods, Radiologe 43 (2003), 823-830. (Pubitemid 37372880)
    • (2003) Radiologe , vol.43 , Issue.10 , pp. 823-830
    • Krix, M.1    Kauczor, H.-U.2    Delorme, S.3
  • 31
    • 9644283317 scopus 로고    scopus 로고
    • Quantification of perfusion of liver tissue and metastases using a multivessel model for replenishment kinetics of ultrasound contrast agents
    • M. Krix, C. Plathow, F. Kiessling, F. Herth, A. Karcher, M. Essig, H. Schmitteckert, H.U. Kauczor and S. Delorme, Quantification of perfusion of liver tissue and metastases using a multivessel model for replenishment kinetics of ultrasound contrast agents, Ultrasound Med. Biol. 30 (2004), 1355-1363.
    • (2004) Ultrasound Med. Biol. , vol.30 , pp. 1355-1363
    • Krix, M.1    Plathow, C.2    Kiessling, F.3    Herth, F.4    Karcher, A.5    Essig, M.6    Schmitteckert, H.7    Kauczor, H.U.8    Delorme, S.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.