Volumn 67, Issue 10, 2009, Pages 1819-1823

Correction factors determination in large samples gamma assay using its own multi-gamma lines spectrum

Author keywords

Gamma assay; Large sample; NORM; Self attenuation; Volume

Indexed keywords

GAMMA ASSAY; LARGE SAMPLE; NORM; SELF-ATTENUATION; VOLUME;

EID: 68949205615     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apradiso.2009.05.014     Document Type: Article
Times cited : (11)

References (10)
  • 1
    • 33746352094 scopus 로고    scopus 로고
    • Calibration of cylindrical detectors using a simplified theoretical approach
    • Abbas M.I., Nafee S., and Selim Y.S. Calibration of cylindrical detectors using a simplified theoretical approach. Appl. Radiat. Isot. 64 (2006) 1057-1064
    • (2006) Appl. Radiat. Isot. , vol.64 , pp. 1057-1064
    • Abbas, M.I.1    Nafee, S.2    Selim, Y.S.3
  • 2
    • 33750460572 scopus 로고    scopus 로고
    • Peak efficiency calibration for attenuation corrected cylindrical sources in gamma ray spectrometry by the use of a point source
    • Aguiar J.C., Galiano E., and Fernandez J. Peak efficiency calibration for attenuation corrected cylindrical sources in gamma ray spectrometry by the use of a point source. Appl. Radiat. Isot. 64 (2006) 1643-1647
    • (2006) Appl. Radiat. Isot. , vol.64 , pp. 1643-1647
    • Aguiar, J.C.1    Galiano, E.2    Fernandez, J.3
  • 3
    • 23544466575 scopus 로고
    • Determination of the full energy peak efficiency for cylindrical volume sources by the use of a point source standard in gamma-spectrometry
    • Haase G., et al. Determination of the full energy peak efficiency for cylindrical volume sources by the use of a point source standard in gamma-spectrometry. Nucl. Instrum. Methods Phys. Res. A 361 (1995) 240-244
    • (1995) Nucl. Instrum. Methods Phys. Res. A , vol.361 , pp. 240-244
    • Haase, G.1
  • 4
    • 0020798962 scopus 로고
    • Variation of Ge-detector efficiency with source diameter and radial source position
    • Helmer R.G. Variation of Ge-detector efficiency with source diameter and radial source position. Int. J. Appl. Radiat. Isot. 34 (1983) 1105-1108
    • (1983) Int. J. Appl. Radiat. Isot. , vol.34 , pp. 1105-1108
    • Helmer, R.G.1
  • 5
    • 68949216498 scopus 로고    scopus 로고
    • JEF-PC Version 2. A PC program for displaying data from the joint evaluated file (JEF) library
    • JEF-PC Version 2. A PC program for displaying data from the joint evaluated file (JEF) library.
  • 6
    • 33748347949 scopus 로고    scopus 로고
    • Self-absorption correction in gamma-ray spectrometry of environmental samples-an overview of methods and correction values obtained for the selected geometries
    • Jodlowski P. Self-absorption correction in gamma-ray spectrometry of environmental samples-an overview of methods and correction values obtained for the selected geometries. Nukleonika 51 2 (2006) S21-S25
    • (2006) Nukleonika , vol.51 , Issue.2
    • Jodlowski, P.1
  • 7
    • 0026807667 scopus 로고
    • Efficiency calibration of gamma-ray spectrometers for volume-source geometry
    • Korun M., and Martincic R. Efficiency calibration of gamma-ray spectrometers for volume-source geometry. Appl. Radiat. Isot. 43 (1992) 29-35
    • (1992) Appl. Radiat. Isot. , vol.43 , pp. 29-35
    • Korun, M.1    Martincic, R.2
  • 8
    • 0027187143 scopus 로고
    • Gamma-ray spectroscopy of voluminous sources corrections for source geometry and self-attenuation
    • Overwater R.M., et al. Gamma-ray spectroscopy of voluminous sources corrections for source geometry and self-attenuation. Nucl. Instrum. Methods Phys. Res. A 324 (1993) 209-218
    • (1993) Nucl. Instrum. Methods Phys. Res. A , vol.324 , pp. 209-218
    • Overwater, R.M.1
  • 9
    • 33750192913 scopus 로고    scopus 로고
    • Correction by self-attenuation in gamma-ray spectrometry for environmental samples
    • Quindo′ S., Sainz L.S., Fuente I., Nicola′ S.J., Quindo′ S.L., and Arteche J. Correction by self-attenuation in gamma-ray spectrometry for environmental samples. Radioanal. Nucl. Chem. 270 2 (2006) 339-343
    • (2006) Radioanal. Nucl. Chem. , vol.270 , Issue.2 , pp. 339-343
    • Quindo, S.1    Sainz, L.S.2    Fuente, I.3    Nicola, S.J.4    Quindo, S.L.5    Arteche, J.6
  • 10
    • 4544331350 scopus 로고    scopus 로고
    • Determination of detection efficiency curves of HPGe detectors on radioactivity measurements of volume samples
    • Saegusa J., et al. Determination of detection efficiency curves of HPGe detectors on radioactivity measurements of volume samples. Appl. Radiat. Isot. 61 (2004) 1383-1390
    • (2004) Appl. Radiat. Isot. , vol.61 , pp. 1383-1390
    • Saegusa, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.