메뉴 건너뛰기




Volumn 64, Issue 12, 2006, Pages 1643-1647

Peak efficiency calibration for attenuation corrected cylindrical sources in gamma ray spectrometry by the use of a point source

Author keywords

Efficiency for cylindrical sources; Gamma peak efficiency; HPGe detectors; Self attenuation of volume sources

Indexed keywords

ATTENUATION; DETECTORS; PHOTONS; SPECTROMETRY;

EID: 33750460572     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apradiso.2006.05.014     Document Type: Article
Times cited : (29)

References (13)
  • 1
    • 4544384312 scopus 로고    scopus 로고
    • Theoretical estimates of the solid angle subtended by a dual diaphragm-detector assembly for alpha sources
    • Aguiar J.C., and Galiano E. Theoretical estimates of the solid angle subtended by a dual diaphragm-detector assembly for alpha sources. Appl. Rad. Isot. 61 (2004) 1349-1351
    • (2004) Appl. Rad. Isot. , vol.61 , pp. 1349-1351
    • Aguiar, J.C.1    Galiano, E.2
  • 2
    • 0033116772 scopus 로고    scopus 로고
    • Systematization of efficiency correction for gamma-ray disk sources with semiconductor detectors
    • Chatini H. Systematization of efficiency correction for gamma-ray disk sources with semiconductor detectors. Nucl. Instrum. Methods. Phys. Res. A 425 (1999) 291-301
    • (1999) Nucl. Instrum. Methods. Phys. Res. A , vol.425 , pp. 291-301
    • Chatini, H.1
  • 4
    • 23544466575 scopus 로고
    • Determination of the full energy peak efficiency for cylindrical volume sources by the use of a point source standard in gamma-spectrometry
    • Haase G., et al. Determination of the full energy peak efficiency for cylindrical volume sources by the use of a point source standard in gamma-spectrometry. Nucl. Instrum. Methods. Phys. Res. A 361 (1995) 240-244
    • (1995) Nucl. Instrum. Methods. Phys. Res. A , vol.361 , pp. 240-244
    • Haase, G.1
  • 5
    • 0020798962 scopus 로고
    • Variation of Ge-Detector efficiency with source diameter and radial source position
    • Helmer R.G. Variation of Ge-Detector efficiency with source diameter and radial source position. Int. J. Appl. Radiat. Isot. 34 (1983) 1105-1108
    • (1983) Int. J. Appl. Radiat. Isot. , vol.34 , pp. 1105-1108
    • Helmer, R.G.1
  • 7
    • 0026807667 scopus 로고
    • Efficiency calibration of gamma-ray spectrometers for volume-source geometry
    • Korun M., and Martincic R. Efficiency calibration of gamma-ray spectrometers for volume-source geometry. Appl. Radiat. Isot. 43 (1992) 29-35
    • (1992) Appl. Radiat. Isot. , vol.43 , pp. 29-35
    • Korun, M.1    Martincic, R.2
  • 9
    • 0019605342 scopus 로고
    • Calculation of the absolute peak efficiency of gamma-ray detectors for different counting geometries
    • Moens L., et al. Calculation of the absolute peak efficiency of gamma-ray detectors for different counting geometries. Nucl. Instrum. Methods. Phys. 187 (1981) 451-472
    • (1981) Nucl. Instrum. Methods. Phys. , vol.187 , pp. 451-472
    • Moens, L.1
  • 10
    • 0019351189 scopus 로고
    • Semi-empirical γ-ray peak efficiency determination including self-absorption correction based on numerical integration
    • Noguchi M., et al. Semi-empirical γ-ray peak efficiency determination including self-absorption correction based on numerical integration. Int. J. Appl. Radiat. Isotopes, 32 (1981) 17-22
    • (1981) Int. J. Appl. Radiat. Isotopes , vol.32 , pp. 17-22
    • Noguchi, M.1
  • 11
    • 0027187143 scopus 로고
    • Gamma-ray spectroscopy of voluminous sources corrections for source geometry and self-attenuation
    • Overwater R.M., et al. Gamma-ray spectroscopy of voluminous sources corrections for source geometry and self-attenuation. Nucl. Instrum. Methods. Phys. Res. A 324 (1993) 209-218
    • (1993) Nucl. Instrum. Methods. Phys. Res. A , vol.324 , pp. 209-218
    • Overwater, R.M.1
  • 12
    • 4544331350 scopus 로고    scopus 로고
    • Determination of detection efficiency curves of HPGe detectors on radioactivity measurements of volume samples
    • Saegusa J., et al. Determination of detection efficiency curves of HPGe detectors on radioactivity measurements of volume samples. Appl. Rad. Isot. 61 (2004) 1383-1390
    • (2004) Appl. Rad. Isot. , vol.61 , pp. 1383-1390
    • Saegusa, J.1
  • 13
    • 0023826915 scopus 로고
    • A computer program for calculating Ge(Li) detector counting efficiencies with large volume samples
    • Zikovsky L., and Chah B. A computer program for calculating Ge(Li) detector counting efficiencies with large volume samples. Nucl. Instrum. Methods. Phys. Res. A 263 (1988) 483-486
    • (1988) Nucl. Instrum. Methods. Phys. Res. A , vol.263 , pp. 483-486
    • Zikovsky, L.1    Chah, B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.