메뉴 건너뛰기




Volumn 51, Issue SUPPL. 2, 2006, Pages

Self-absorption correction in gamma-ray spectrometry of environmental samples - An overview of methods and correction values obtained for the selected geometries

Author keywords

Correction factor; Gamma ray spectrometry; Self absorption; Self attenuation

Indexed keywords


EID: 33748347949     PISSN: 00295922     EISSN: 15085791     Source Type: Journal    
DOI: None     Document Type: Conference Paper
Times cited : (35)

References (21)
  • 2
    • 0030284873 scopus 로고    scopus 로고
    • A method for the determination of counting efficiencies in γ-spectrometric measurements with HPGe detectors
    • Bolivar JP, García-Tenorio R, García-León M (1996) A method for the determination of counting efficiencies in γ-spectrometric measurements with HPGe detectors. Nucl Instrum Methods Phys Res A 382:495-502
    • (1996) Nucl Instrum Methods Phys Res A , vol.382 , pp. 495-502
    • Bolivar, J.P.1    García-Tenorio, R.2    García-León, M.3
  • 3
    • 0035131205 scopus 로고    scopus 로고
    • Corrections for self-attenuation in gamma-ray spectroscopy of bulk samples
    • Boshkova T, Minev L (2001) Corrections for self-attenuation in gamma-ray spectroscopy of bulk samples. Appl Radiat Isot 54:777-783
    • (2001) Appl Radiat Isot , vol.54 , pp. 777-783
    • Boshkova, T.1    Minev, L.2
  • 4
    • 9144243735 scopus 로고    scopus 로고
    • Automated efficiency calibration of HPGe spectrometers for in-vitro soil samples
    • Bostock IJ, Taulbee TD (1999) Automated efficiency calibration of HPGe spectrometers for in-vitro soil samples. Nucl Instrum Methods Phys Res A 422:812-816
    • (1999) Nucl Instrum Methods Phys Res A , vol.422 , pp. 812-816
    • Bostock, I.J.1    Taulbee, T.D.2
  • 5
    • 0000831705 scopus 로고
    • Direct analysis of Pb-210 in sediment samples: A self-absorption corrections
    • Cutshall N, Larsen IL, Olsen CR (1983) Direct analysis of Pb-210 in sediment samples: a self-absorption corrections. Nucl Instrum Methods Phys Res 206:309-312
    • (1983) Nucl Instrum Methods Phys Res , vol.206 , pp. 309-312
    • Cutshall, N.1    Larsen, I.L.2    Olsen, C.R.3
  • 7
    • 0024686505 scopus 로고
    • Measurement of activity of radioactive samples in Marinelli beakers
    • Debertin K, Ren J (1989) Measurement of activity of radioactive samples in Marinelli beakers. Nucl Instrum Methods Phys Res A 278:541-549
    • (1989) Nucl Instrum Methods Phys Res A , vol.278 , pp. 541-549
    • Debertin, K.1    Ren, J.2
  • 10
    • 0027693793 scopus 로고
    • Application of new Monte Carlo method for determination of summation and self-attenuation corrections in gamma spectrometry
    • Haase G, Tait D, Wiechen A (1993) Application of new Monte Carlo method for determination of summation and self-attenuation corrections in gamma spectrometry. Nucl Instrum Methods Phys Res A 336:206-214
    • (1993) Nucl Instrum Methods Phys Res A , vol.336 , pp. 206-214
    • Haase, G.1    Tait, D.2    Wiechen, A.3
  • 11
    • 0037150148 scopus 로고    scopus 로고
    • Semi-empirical method for self-absorption correction of photons with energies as low as 10 keV in environmental samples
    • Hernández F, El-Daoushy F (2002) Semi-empirical method for self-absorption correction of photons with energies as low as 10 keV in environmental samples. Nucl Instrum Methods Phys Res A 484:625-641
    • (2002) Nucl Instrum Methods Phys Res A , vol.484 , pp. 625-641
    • Hernández, F.1    El-Daoushy, F.2
  • 12
    • 0024474434 scopus 로고
    • Determination of Am-241 in sediments by direct counting of low-energy photons
    • Joshi SR (1989) Determination of Am-241 in sediments by direct counting of low-energy photons. Int J Radiat Applic Instrum A 40:691-699
    • (1989) Int J Radiat Applic Instrum A , vol.40 , pp. 691-699
    • Joshi, S.R.1
  • 13
    • 0033938730 scopus 로고    scopus 로고
    • Calculation of self-attenuation factors in gamma-ray spectrometry for samples of arbitrary shape
    • Korun M (2000) Calculation of self-attenuation factors in gamma-ray spectrometry for samples of arbitrary shape. J Radioanal Nucl Chem 244:685-689
    • (2000) J Radioanal Nucl Chem , vol.244 , pp. 685-689
    • Korun, M.1
  • 14
    • 0038715740 scopus 로고    scopus 로고
    • Self-absorption correction factor applied to I-129 measurement by direct gamma-X spectrometry for Fucus serratus samples
    • Lefèvre O, Bouisset P, Germain P, Barker E, Kerlau G, Cagnat X (2003) Self-absorption correction factor applied to I-129 measurement by direct gamma-X spectrometry for Fucus serratus samples. Nucl Instrum Methods Phys Res A 506:173-185
    • (2003) Nucl Instrum Methods Phys Res A , vol.506 , pp. 173-185
    • Lefèvre, O.1    Bouisset, P.2    Germain, P.3    Barker, E.4    Kerlau, G.5    Cagnat, X.6
  • 15
    • 0029016820 scopus 로고
    • Measurement of radioactive samples in Marinelli beakers by gamma-ray spectrometry
    • Park TS, Jeon WJ (1995) Measurement of radioactive samples in Marinelli beakers by gamma-ray spectrometry. J Radioanal Nucl Chem 193:133-144
    • (1995) J Radioanal Nucl Chem , vol.193 , pp. 133-144
    • Park, T.S.1    Jeon, W.J.2
  • 17
    • 0031986245 scopus 로고    scopus 로고
    • A new method for gamma-efficiency calibration of voluminal samples in cylindrical geometry
    • Ramos-Lerate I, Barrera M, Ligero RA, Casas-Ruiz M (1998) A new method for gamma-efficiency calibration of voluminal samples in cylindrical geometry. J Environ Radioact 38:47-57
    • (1998) J Environ Radioact , vol.38 , pp. 47-57
    • Ramos-Lerate, I.1    Barrera, M.2    Ligero, R.A.3    Casas-Ruiz, M.4
  • 18
    • 0001432286 scopus 로고
    • A Monte Carlo based method of including gamma self-absorption for the analysis of environmental samples
    • Sanchez F, Navarro E, Ferrero JL et al. (1991) A Monte Carlo based method of including gamma self-absorption for the analysis of environmental samples. Nucl Instrum Methods Phys Res B 61:535-540
    • (1991) Nucl Instrum Methods Phys Res B , vol.61 , pp. 535-540
    • Sanchez, F.1    Navarro, E.2    Ferrero, J.L.3
  • 19
    • 0026630291 scopus 로고
    • Photon attenuation for samples in Marinelli beaker geometry: An analytical computation
    • Sima O (1992) Photon attenuation for samples in Marinelli beaker geometry: an analytical computation. Health Phys 62:445-449
    • (1992) Health Phys , vol.62 , pp. 445-449
    • Sima, O.1
  • 20
    • 0031036779 scopus 로고    scopus 로고
    • Matrix effects in the activity measurement of environmental samples - Implementation of specific corrections in gamma-ray spectrometry analysis program
    • Sima O, Dovlete C (1997) Matrix effects in the activity measurement of environmental samples - implementation of specific corrections in gamma-ray spectrometry analysis program. Appl Radiat Isot 48:59-69
    • (1997) Appl Radiat Isot , vol.48 , pp. 59-69
    • Sima, O.1    Dovlete, C.2
  • 21
    • 0036888622 scopus 로고    scopus 로고
    • Monte Carlo simulation of the self-absorption corrections for natural samples in gamma-ray spectrometry
    • Vargas MJ, Timón AF, Diaz NC, Sánchez DP (2002) Monte Carlo simulation of the self-absorption corrections for natural samples in gamma-ray spectrometry. Appl Radiat Isot 57:893-898
    • (2002) Appl Radiat Isot , vol.57 , pp. 893-898
    • Vargas, M.J.1    Timón, A.F.2    Diaz, N.C.3    Sánchez, D.P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.