메뉴 건너뛰기




Volumn 14, Issue 4, 2009, Pages 365-369

Pulsatile perfusion of kidney allografts

Author keywords

Allograft utilization; Deceased donor kidney transplants; Delayed graft function; Expanded criteria donors; Pulsatile perfusion

Indexed keywords

CLINICAL TRIAL; CRYOPRESERVATION; DELAYED GRAFT FUNCTION; GRAFT SURVIVAL; HUMAN; KIDNEY ALLOGRAFT; KIDNEY DONOR; KIDNEY PERFUSION; KIDNEY TRANSPLANTATION; ORGAN PRESERVATION; POSTOPERATIVE COMPLICATION; RENAL GRAFT DYSFUNCTION; REVIEW; TREATMENT OUTCOME;

EID: 68849125459     PISSN: 10872418     EISSN: 15317013     Source Type: Journal    
DOI: 10.1097/MOT.0b013e32832dbd1c     Document Type: Review
Times cited : (13)

References (25)
  • 2
    • 33845411090 scopus 로고    scopus 로고
    • Microscopic intrarenal particles after pulsatile machine preservation do not adversely affect outcomes after renal transplantation
    • Guarrera JV, Nasr SH, Reverte CM, et al. Microscopic intrarenal particles after pulsatile machine preservation do not adversely affect outcomes after renal transplantation. Transplant Proc 2006; 38:3384-3387.
    • (2006) Transplant Proc , vol.38 , pp. 3384-3387
    • Guarrera, J.V.1    Nasr, S.H.2    Reverte, C.M.3
  • 3
    • 33644800846 scopus 로고    scopus 로고
    • The role of preservation solution on acid-base regulation during machine perfusion of kidneys
    • DOI 10.1111/j.1399-0012.2005.00451.x
    • Baicu SC, Taylor MJ, Brockbank KGM. The role of preservation solution on acid-base regulation during machine perfusion of kidneys. Clin Transplant 2006; 20:113-121. (Pubitemid 43349036)
    • (2006) Clinical Transplantation , vol.20 , Issue.1 , pp. 113-121
    • Baicu, S.C.1    Taylor, M.J.2    Brockbank, K.G.M.3
  • 4
    • 40449114234 scopus 로고    scopus 로고
    • Determinants of discard of expanded criteria donor kidneys: Impact of biopsy and machine perfusion
    • see comment. Sung et al. reviewed data from Scientific Registry of Transplant Recipients (SRTR)/organ Procurement and Transplantation Network OPTN using logistic regression. Fewer ECD kidneys were discarded when pumped (29.7 vs. 43/6%). Those ECD kidneys pumped were also less likely to have DGF but not graft failure
    • Sung RS, Christensen LL, Leichtman AB, et al. Determinants of discard of expanded criteria donor kidneys: impact of biopsy and machine perfusion [see comment]. Am J Transplant 2008; 8:783-792. Sung et al. reviewed data from Scientific Registry of Transplant Recipients (SRTR)/organ Procurement and Transplantation Network OPTN) using logistic regression. Fewer ECD kidneys were discarded when pumped (29.7 vs. 43/6%). Those ECD kidneys pumped were also less likely to have DGF but not graft failure.
    • (2008) Am J Transplant , vol.8 , pp. 783-792
    • Sung, R.S.1    Christensen, L.L.2    Leichtman, A.B.3
  • 5
    • 33645065609 scopus 로고    scopus 로고
    • Tissue pulsatility index: A new parameter to evaluate renal transplant perfusion
    • Scholbach T, Girelli E, Scholbach J. Tissue pulsatility index: a new parameter to evaluate renal transplant perfusion. Transplantation 2006; 81:751-755.
    • (2006) Transplantation , vol.81 , pp. 751-755
    • Scholbach, T.1    Girelli, E.2    Scholbach, J.3
  • 7
    • 33745705886 scopus 로고    scopus 로고
    • Endoplasmic and vascular surface activation during organ preservation: Refining upon the benefits of machine perfusion
    • DOI 10.1111/j.1600-6143.2006.01338.x
    • Minor T, Manekeller S, Sioutis M, Dombrowski F. Endoplasmic and vascular surface activation during organ preservation: refining upon the benefits of machine perfusion. Am J Transplant 2006; 6:1355-1366. (Pubitemid 44030318)
    • (2006) American Journal of Transplantation , vol.6 , Issue.6 , pp. 1355-1366
    • Minor, T.1    Manekeller, S.2    Sioutis, M.3    Dombrowski, F.4
  • 8
    • 33750008378 scopus 로고    scopus 로고
    • Redox-active iron released during machine perfusion predicts viability of ischemically injured deceased donor kidneys
    • de Vries B, Snoeijs MGJ, von Bonsdorff L, et al. Redox-active iron released during machine perfusion predicts viability of ischemically injured deceased donor kidneys. Am J Transplant 2006; 6:2686-2693.
    • (2006) Am J Transplant , vol.6 , pp. 2686-2693
    • De Vries, B.1    Snoeijs, M.G.J.2    Von Bonsdorff, L.3
  • 9
    • 0036257594 scopus 로고    scopus 로고
    • Early function of kidneys stored by continuous hypothermic pulsatile perfusion can be predicted using a new 'viability index'
    • Kosieradzki M, Danielewicz R, Kwiatkowski A, et al. Early function of kidneys stored by continuous hypothermic pulsatile perfusion can be predicted using a new 'viability index'. Transplant Proc 2002; 34:541-543.
    • (2002) Transplant Proc , vol.34 , pp. 541-543
    • Kosieradzki, M.1    Danielewicz, R.2    Kwiatkowski, A.3
  • 11
    • 65649139609 scopus 로고    scopus 로고
    • Pulsatile perfusion preservation of en bloc kidneys from small pediatric donors
    • Sageshima J, Ciancio G, Burke L, et al. Pulsatile perfusion preservation of en bloc kidneys from small pediatric donors. Transplantation 2009; 87:782.
    • (2009) Transplantation , vol.87 , pp. 782
    • Sageshima, J.1    Ciancio, G.2    Burke, L.3
  • 13
    • 49649101853 scopus 로고    scopus 로고
    • Impact of pulsatile perfusion on postoperative outcomes of kidneys from controlled donors after cardiac death
    • Plata-Munoz J, Muthusamy A, Quiroga I, et al. Impact of pulsatile perfusion on postoperative outcomes of kidneys from controlled donors after cardiac death. Transplant Int 2008; 21:899-907.
    • (2008) Transplant Int , vol.21 , pp. 899-907
    • Plata-Munoz, J.1    Muthusamy, A.2    Quiroga, I.3
  • 14
    • 58249089430 scopus 로고    scopus 로고
    • Machine perfusion of cold storage in deceased donor kidney transplantation
    • A recent article this year published by Moers et al. prospectively randomized donor kidneys such that one was stored with pulsatile perfusion and one via traditional cold storage. Although the study had relatively short ischemic times, it was sufficiently powered with over 300 paired kidneys studied. They showed a statistically significant decrease in DGF and an improvement in outcomes at 1 year
    • Moers C, Smits J, Maathuis M, et al. Machine perfusion of cold storage in deceased donor kidney transplantation. N Engl J Med 2009; 360: 7-19. A recent article this year published by Moers et al. prospectively randomized donor kidneys such that one was stored with pulsatile perfusion and one via traditional cold storage. Although the study had relatively short ischemic times, it was sufficiently powered with over 300 paired kidneys studied. They showed a statistically significant decrease in DGF and an improvement in outcomes at 1 year.
    • (2009) N Engl J Med , vol.360 , pp. 7-19
    • Moers, C.1    Smits, J.2    Maathuis, M.3
  • 15
    • 35348897233 scopus 로고    scopus 로고
    • Risk Factors for Delayed Renal Graft Function and Their Impact on Renal Transplantation Outcome
    • DOI 10.1016/j.transproceed.2007.07.032, PII S0041134507008676
    • Figueiredo A, Moreira P, Parada B, et al. Risk factors for delayed renal graft function and their impact on renal transplantation outcome. Transplant Proc 2007; 39:2473-2475. (Pubitemid 47588362)
    • (2007) Transplantation Proceedings , vol.39 , Issue.8 , pp. 2473-2475
    • Figueiredo, A.1    Moreira, P.2    Parada, B.3    Nunes, P.4    Macario, F.5    Bastos, C.6    Mota, A.7
  • 19
    • 33845463809 scopus 로고    scopus 로고
    • Is pulsatile perfusion necessary for renal transplantation engrafting kidneys from cardiac death donors?
    • Kusaka M, Kubota Y, Sasaki H, et al. Is pulsatile perfusion necessary for renal transplantation engrafting kidneys from cardiac death donors? Transplant Proc 2006; 38:3388-3389.
    • (2006) Transplant Proc , vol.38 , pp. 3388-3389
    • Kusaka, M.1    Kubota, Y.2    Sasaki, H.3
  • 20
    • 56049104916 scopus 로고    scopus 로고
    • Comparison of pulsatile perfusion and cold storage for paired kidney allografts
    • Shah A, Milgrom D, Mangus R. Comparison of pulsatile perfusion and cold storage for paired kidney allografts. Transplantation 2008; 86:1006-1009.
    • (2008) Transplantation , vol.86 , pp. 1006-1009
    • Shah, A.1    Milgrom, D.2    Mangus, R.3
  • 22
    • 33846941158 scopus 로고    scopus 로고
    • Multicenter analysis of kidney preservation
    • Opelz G, Dohler B. Multicenter analysis of kidney preservation. Transplantation 2007; 83:247-253.
    • (2007) Transplantation , vol.83 , pp. 247-253
    • Opelz, G.1    Dohler, B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.