-
1
-
-
0033034874
-
Comparison of different biomaterials for glaucoma drainage devices
-
Ayyala, RS, LE Harman, B Michelini-Norris, LE Ondrovic, E Haller, CE Margo, and SX Stevens (1999). Comparison of different biomaterials for glaucoma drainage devices. Arch Ophthalmol, 117, 233-36.
-
(1999)
Arch Ophthalmol
, vol.117
, pp. 233-36
-
-
Ayyala, R.S.1
Harman, L.E.2
Michelini-Norris, B.3
Ondrovic, L.E.4
Haller, E.5
Margo, C.E.6
Stevens, S.X.7
-
2
-
-
0033901338
-
Comparison of different biomaterials for glaucoma drainage devices
-
Ayyala, RS, FB Michelini-Norris, A Flores, E Hallerm, and CE Margo (2000). Comparison of different biomaterials for glaucoma drainage devices. Arch Ophthalmol, 118, 1081-84.
-
(2000)
Arch Ophthalmol
, vol.118
, pp. 1081-84
-
-
Ayyala, R.S.1
Michelini-Norris, F.B.2
Flores, A.3
Hallerm, E.4
Margo, C.E.5
-
3
-
-
33644810720
-
Undecalcified bone samples: A description of the technique and its utility based on the literature
-
Cano-Sánchez, J, J Campo-Trapero, JC Gonzalo-Lafuente, LA Moreno-López, and A Bascones-Martínez (2005). Undecalcified bone samples: a description of the technique and its utility based on the literature. Med Oral Patol Oral Cir Bucal, 10 (Suppl). E74-87.
-
(2005)
Med Oral Patol Oral Cir Bucal
, vol.10
, Issue.SUPPL
, pp. 74-87
-
-
Cano-Sánchez, J.1
Campo-Trapero, J.2
Gonzalo-Lafuente, J.C.3
Moreno-López, L.A.4
Bascones-Martínez, A.5
-
4
-
-
33846638813
-
Ex-PRESS miniature glaucoma implant inserted under a scleral flap in open-angle glaucoma surgery: A retrospective study
-
Coupin, A, Q Li, and I Riss (2007). Ex-PRESS miniature glaucoma implant inserted under a scleral flap in open-angle glaucoma surgery: A retrospective study. J Fr. Ophtalmol, 30, 18-23.
-
(2007)
J Fr. Ophtalmol
, vol.30
, pp. 18-23
-
-
Coupin, A.1
Li, Q.2
Riss, I.3
-
5
-
-
15244356830
-
Implantation of a miniature glaucoma device under a scleral flap
-
Dahan, E, and TR Carmichael (2005). Implantation of a miniature glaucoma device under a scleral flap. J Glaucoma, 14, 98-102.
-
(2005)
J Glaucoma
, vol.14
, pp. 98-102
-
-
Dahan, E.1
Carmichael, T.R.2
-
6
-
-
68649123924
-
Incisional surgery
-
A Heijl and CE Traverso (Eds.), 3rd ed (pp. Savona, Italy: European Glaucoma Society.
-
European Glaucoma Society (2008). Incisional surgery. In A Heijl and CE Traverso (Eds.), Terminology and guidelines for glaucoma, 3rd ed (pp. 153-57). Savona, Italy: European Glaucoma Society.
-
(2008)
Terminology and Guidelines for Glaucoma
, pp. 153-57
-
-
Glaucoma Society, E.1
-
7
-
-
0026832945
-
The mechanisms of passive dissolution of titanium in a model of physiochemical environment
-
Healy, KE, and P Ducheyne (1992). The mechanisms of passive dissolution of titanium in a model of physiochemical environment. J Biomed Mater Res, 26, 319-38.
-
(1992)
J Biomed Mater Res
, vol.26
, pp. 319-38
-
-
Healy, K.E.1
Ducheyne, P.2
-
8
-
-
0029955923
-
Long-term histologic studies of the Baerveldt implant in the rabbit model
-
Lloyd, MA, G Baerveldt, QH Nguyen, and DS Minckler (1996). Long-term histologic studies of the Baerveldt implant in the rabbit model. J Glaucoma, 5, 334-39.
-
(1996)
J Glaucoma
, vol.5
, pp. 334-39
-
-
Lloyd, M.A.1
Baerveldt, G.2
Nguyen, Q.H.3
Minckler, D.S.4
-
9
-
-
33846310799
-
Comparison of trabeculectomy with Ex-PRESS miniature glaucoma device implanted under scleral flap
-
Maris, PJ, K Ishida, and PA Netland (2007). Comparison of trabeculectomy with Ex-PRESS miniature glaucoma device implanted under scleral flap. J Glaucoma, 16, 14-19.
-
(2007)
J Glaucoma
, vol.16
, pp. 14-19
-
-
Maris, P.J.1
Ishida, K.2
Netland, P.A.3
-
10
-
-
16244372040
-
Ex-PRESS implant
-
Mermoud, A (2005). Ex-PRESS implant. Br J Ophthalmol, 89, 396-97.
-
(2005)
Br J Ophthalmol
, vol.89
, pp. 396-97
-
-
Mermoud, A.1
-
11
-
-
33747360012
-
Surgical trauma: Pseudophakic and aphakic corneal edema
-
JH Krachmer, MJ Mannis and EJ Holland (Eds.), 2nd ed (pp. St. Louis, MO: Elsevier Mosby.
-
Mian, S, and A Sugar (2005). Surgical trauma: Pseudophakic and aphakic corneal edema. In JH Krachmer, MJ Mannis and EJ Holland (Eds.), Cornea, 2nd ed (pp. 1263-76). St. Louis, MO: Elsevier Mosby.
-
(2005)
Cornea
, pp. 1263-76
-
-
Mian, S.1
Sugar, A.2
-
12
-
-
0037972519
-
Biocompatibility of the Ex-PRESS miniature glaucoma drainage implant
-
Nyska, A, Y Glovinsky, M Belkin, and Y Epstein (2003). Biocompatibility of the Ex-PRESS miniature glaucoma drainage implant. J Glaucoma, 12, 275-80.
-
(2003)
J Glaucoma
, vol.12
, pp. 275-80
-
-
Nyska, A.1
Glovinsky, Y.2
Belkin, M.3
Epstein, Y.4
-
13
-
-
0031553834
-
Types i and III collagen in the tissue capsules of titanium and stainless-steel implants
-
Shannon, C, R Thull, and A Von Recum (1997). Types I and III collagen in the tissue capsules of titanium and stainless-steel implants. J Biomed Mater Res, 34, 401-8.
-
(1997)
J Biomed Mater Res
, vol.34
, pp. 401-8
-
-
Shannon, C.1
Thull, R.2
Von Recum, A.3
-
14
-
-
20144387822
-
Long term effect on IOP of a stainless steel glaucoma drainage implant (Ex-PRESS) in combined surgery with phacoemulsification
-
Traverso, CE, F De Feo, A Messas-Kaplan, P Denis, S Levartovsky, E Sellem, F Badalá, Z Zagorski, A Bron, S Gandolfi, and M Belkin (2005). Long term effect on IOP of a stainless steel glaucoma drainage implant (Ex-PRESS) in combined surgery with phacoemulsification. Br J Ophthalmol, 89, 425-29.
-
(2005)
Br J Ophthalmol
, vol.89
, pp. 425-29
-
-
Traverso, C.E.1
De Feo, F.2
Messas-Kaplan, A.3
Denis, P.4
Levartovsky, S.5
Sellem, E.6
Badalá, F.7
Zagorski, Z.8
Bron, A.9
Gandolfi, S.10
Belkin, M.11
-
15
-
-
0025157958
-
The complications of trabeculectomy (a 20-year follow-up)
-
Watson, PG, C Jakeman, M Ozturk, MF Barnett, F Barnett, and KT Khaw (1990). The complications of trabeculectomy (a 20-year follow-up). Eye, 4, 425-38.
-
(1990)
Eye
, vol.4
, pp. 425-38
-
-
Watson, P.G.1
Jakeman, C.2
Ozturk, M.3
Barnett, M.F.4
Barnett, F.5
Khaw, K.T.6
|