Volumn 30, Issue 1, 2007, Pages 18-23

Ex-PRESS™ miniature glaucoma implant inserted under a scleral flap in open-angle glaucoma surgery: A retrospective study;Implant miniature Ex-PRESS™ placé sous un volet scléral dans la chirurgie du glaucome à angle ouvert: Étude rétrospective

Author keywords

Ex PRESS; IOP (intraocular pressure); OAG (open angle glaucoma); Scleral flap

Indexed keywords

ANESTHETIC AGENT; ANTIGLAUCOMA AGENT; EYE DROPS; MITOMYCIN; NONSTEROID ANTIINFLAMMATORY AGENT;

EID: 33846638813     PISSN: 01815512     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0181-5512(07)89545-3     Document Type: Article
Times cited : (44)

References (19)
  • 1
    • 0029980777 scopus 로고    scopus 로고
    • Number of people with glaucoma worldwide
    • HA Quigley. Number of people with glaucoma worldwide. Br J Ophthalmol, 1996;80:389-93.
    • (1996) Br J Ophthalmol , vol.80 , pp. 389-393
    • Quigley, H.A.1
  • 5
    • 20144387822 scopus 로고    scopus 로고
    • Long term effect on IOP of a stainless steel glaucoma drainage implant (Ex-PRESS) in combined surgery with phacoemulsification
    • Traverso CE, De Feo F, Messas-Kaplan A, Denis P, Levartovsky S, Sellem E, et al. Long term effect on IOP of a stainless steel glaucoma drainage implant (Ex-PRESS) in combined surgery with phacoemulsification. Br J Ophthalmol, 2005;89:425-9.
    • (2005) Br J Ophthalmol , vol.89 , pp. 425-429
    • Traverso, C.E.1    De Feo, F.2    Messas-Kaplan, A.3    Denis, P.4    Levartovsky, S.5    Sellem, E.6
  • 6
    • 0030775555 scopus 로고    scopus 로고
    • Long-term follow-up of initially successful trabeculectomy
    • Chen TC, Wilensky JT, Viana MAG. Long-term follow-up of initially successful trabeculectomy. Ophthalmology, 1997;104:1120-5.
    • (1997) Ophthalmology , vol.104 , pp. 1120-1125
    • Chen, T.C.1    Wilensky, J.T.2    Viana, M.A.G.3
  • 7
    • 0019856821 scopus 로고
    • Trabeculectomy: A retrospective long-term follow-up of 444 cases
    • Mills KB. Trabeculectomy: a retrospective long-term follow-up of 444 cases. Br J Ophthalmol, 1981;65:790-5.
    • (1981) Br J Ophthalmol , vol.65 , pp. 790-795
    • Mills, K.B.1
  • 9
    • 15244356830 scopus 로고    scopus 로고
    • Implantation of a miniature glaucoma device under a scleral flap
    • Dahan E, Carmichel TR. Implantation of a miniature glaucoma device under a scleral flap. J Glaucoma, 2005;14:98-102.
    • (2005) J Glaucoma , vol.14 , pp. 98-102
    • Dahan, E.1    Carmichel, T.R.2
  • 10
    • 0037972519 scopus 로고    scopus 로고
    • Biocompatibility of the Ex-PRESS miniature glaucoma drainage implant
    • Nyska A, Glovinsky Y, Belkin M, Epstein Y. Biocompatibility of the Ex-PRESS miniature glaucoma drainage implant. J Glaucoma, 2003;12:275-80.
    • (2003) J Glaucoma , vol.12 , pp. 275-280
    • Nyska, A.1    Glovinsky, Y.2    Belkin, M.3    Epstein, Y.4
  • 12
    • 85030514498 scopus 로고    scopus 로고
    • Two years results in open angle glaucoma following Ex-PRESS™ miniature glaucoma implantation combined with cataract extraction. American Academy of Ophthalmology AAO
    • Traverso C, Gandolfi S, Sellem E. Long term follow-up of the Ex-PRESS™ implant in open angle glaucoma. Two years results in open angle glaucoma following Ex-PRESS™ miniature glaucoma implantation combined with cataract extraction. American Academy of Ophthalmology (AAO), 2003.
    • (2003) Long term follow-up of the Ex-PRESS™ implant in open angle glaucoma
    • Traverso, C.1    Gandolfi, S.2    Sellem, E.3
  • 14
    • 0030856573 scopus 로고    scopus 로고
    • Late onset of sequential multifocal bleb leaks after glaucoma filtration surgery with 5-FU and MMC
    • Belyea DA, Dan JA, Stamper RL, Lieberman MF, Spencer WH. Late onset of sequential multifocal bleb leaks after glaucoma filtration surgery with 5-FU and MMC. Am J Ophthalmol, 1997;124:40-5.
    • (1997) Am J Ophthalmol , vol.124 , pp. 40-45
    • Belyea, D.A.1    Dan, J.A.2    Stamper, R.L.3    Lieberman, M.F.4    Spencer, W.H.5
  • 15
    • 0029098131 scopus 로고
    • Success rates and complications of intraoperative 0.2 mg/ml MMC in trabeculectomy surgery
    • Singh J, O'Brien C, Chawla HB. Success rates and complications of intraoperative 0.2 mg/ml MMC in trabeculectomy surgery. Eye, 1995;9:460-6.
    • (1995) Eye , vol.9 , pp. 460-466
    • Singh, J.1    O'Brien, C.2    Chawla, H.B.3
  • 18
    • 0033010554 scopus 로고    scopus 로고
    • Combined surgery for cataract and glaucoma: Phacoemulsification and deep sclerectomy compared with phacoemulsification and trabeculectomy
    • Gianoli F, Schnyder CC, Bovey E, Mermoud A. Combined surgery for cataract and glaucoma: phacoemulsification and deep sclerectomy compared with phacoemulsification and trabeculectomy. J Cataract Refract Surg, 1999;25:340-6.
    • (1999) J Cataract Refract Surg , vol.25 , pp. 340-346
    • Gianoli, F.1    Schnyder, C.C.2    Bovey, E.3    Mermoud, A.4
  • 19
    • 11144318619 scopus 로고    scopus 로고
    • Results of the use of the Ex-PRESS miniature glaucoma implant in technically challenging, advanced glaucoma cases: A clinical pilot study
    • Wamsley S, Moster MR, Rai S, Alvim HS, Fontanarosa J. Results of the use of the Ex-PRESS miniature glaucoma implant in technically challenging, advanced glaucoma cases: a clinical pilot study. Am J Ophthalmol, 2004;138:1049-51.
    • (2004) Am J Ophthalmol , vol.138 , pp. 1049-1051
    • Wamsley, S.1    Moster, M.R.2    Rai, S.3    Alvim, H.S.4    Fontanarosa, J.5