메뉴 건너뛰기




Volumn 24, Issue 6, 2009, Pages 941-944

Preliminary Results of an Uncemented Trabecular Metal Tibial Component in Total Knee Arthroplasty

Author keywords

total knee arthroplasty; trabecular metal; uncemented

Indexed keywords

METAL; TANTALUM;

EID: 68649084294     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2008.06.018     Document Type: Article
Times cited : (24)

References (10)
  • 3
    • 10344237551 scopus 로고    scopus 로고
    • Clinical validation of a structural porous tantalum biomaterial for adult reconstruction
    • Bobyn J.D., Poggie R.A., Krygier J.J., et al. Clinical validation of a structural porous tantalum biomaterial for adult reconstruction. J Bone Joint Surg Am 86 (2004) 123
    • (2004) J Bone Joint Surg Am , vol.86 , pp. 123
    • Bobyn, J.D.1    Poggie, R.A.2    Krygier, J.J.3
  • 4
    • 0032886563 scopus 로고    scopus 로고
    • Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial
    • Bobyn J.D., Stackpool G.J., Hacking S.A., et al. Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial. J Bone Joint Surg Br 81 (1999) 907
    • (1999) J Bone Joint Surg Br , vol.81 , pp. 907
    • Bobyn, J.D.1    Stackpool, G.J.2    Hacking, S.A.3
  • 5
    • 33846069722 scopus 로고    scopus 로고
    • Press-fit condylar design total knee arthroplasty-fourteen to seventeen-year follow-up
    • Rodricks D.J., Patil S., Pulido P., et al. Press-fit condylar design total knee arthroplasty-fourteen to seventeen-year follow-up. J Bone Joint Surg Am 89 (2007) 89
    • (2007) J Bone Joint Surg Am , vol.89 , pp. 89
    • Rodricks, D.J.1    Patil, S.2    Pulido, P.3
  • 6
    • 0029850588 scopus 로고    scopus 로고
    • Kinematic condylar total knee arthroplasty-14-year survivorship analysis of 208 consecutive cases
    • Weir D.J., Moran C.G., and Pinder I.M. Kinematic condylar total knee arthroplasty-14-year survivorship analysis of 208 consecutive cases. J Bone Joint Surg Br 78 (1996) 907
    • (1996) J Bone Joint Surg Br , vol.78 , pp. 907
    • Weir, D.J.1    Moran, C.G.2    Pinder, I.M.3
  • 7
    • 0034959851 scopus 로고    scopus 로고
    • Long term follow-up of anatomic graduated components posterior cruciate-retaining total knee replacement
    • Ritter M.A., Berend M.E., Meding J.B., et al. Long term follow-up of anatomic graduated components posterior cruciate-retaining total knee replacement. Clin Orthop Relat Res 388 (2002) 51
    • (2002) Clin Orthop Relat Res , vol.388 , pp. 51
    • Ritter, M.A.1    Berend, M.E.2    Meding, J.B.3
  • 8
    • 5344246581 scopus 로고    scopus 로고
    • Uncemented rotating-platform total knee replacement: a five to twelve-year follow-up study
    • Sorrels R.B., Voorhorst P.E., Murphy J.A., et al. Uncemented rotating-platform total knee replacement: a five to twelve-year follow-up study. J Bone Joint Surg Am 86 (2004) 2156
    • (2004) J Bone Joint Surg Am , vol.86 , pp. 2156
    • Sorrels, R.B.1    Voorhorst, P.E.2    Murphy, J.A.3
  • 9
    • 8644235012 scopus 로고    scopus 로고
    • The outcome of the cementless tibial component: a minimum 14-year clinical evaluation
    • Goldberg V.M., and Kraay M. The outcome of the cementless tibial component: a minimum 14-year clinical evaluation. Clin Orthop Relat Res 428 (2004) 214
    • (2004) Clin Orthop Relat Res , vol.428 , pp. 214
    • Goldberg, V.M.1    Kraay, M.2
  • 10
    • 0344035510 scopus 로고    scopus 로고
    • Fixation of a hydroxyapatite-tricalcium phosphate-coated cementless knee prosthesis-clinical and radiographic evaluation seven years after surgery
    • Akizuki S., Takizawa T., and Horiuchi H. Fixation of a hydroxyapatite-tricalcium phosphate-coated cementless knee prosthesis-clinical and radiographic evaluation seven years after surgery. J Bone Joint Surg Br 85 (2003) 1123
    • (2003) J Bone Joint Surg Br , vol.85 , pp. 1123
    • Akizuki, S.1    Takizawa, T.2    Horiuchi, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.