메뉴 건너뛰기




Volumn 19, Issue 4, 2009, Pages 862-865

Mechanical properties and corrosion resistance of low rigidity quaternary titanium alloy for biomedical applications

Author keywords

biomaterial; corrosion; mechanical properties; Ti 35Nb 5Ta 7Zr

Indexed keywords

ARC-MELTING; BIOMEDICAL APPLICATIONS; COMMERCIAL ALLOYS; CORROSION BEHAVIOR; FABRICATED ALLOYS; HEAT TREATMENT PROCESS; IMPEDANCE SPECTROSCOPY; POTENTIODYNAMIC POLARIZATION TECHNIQUE; SCANNING ELECTRON MICROSCOPE; TENSILE TESTS; TI-35NB-5TA-7ZR; TI-6AL-4V; X RAY DIFFRACTOMETERS; YIELD STRENGTH;

EID: 68549090710     PISSN: 10036326     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1003-6326(08)60365-9     Document Type: Article
Times cited : (24)

References (17)
  • 1
    • 9644270305 scopus 로고    scopus 로고
    • Production of new titanium alloy for orthopedic implants [J]
    • TADDEI E.B., HENRIQUES V., SILVA C.R.M., and CAIRO C. Production of new titanium alloy for orthopedic implants [J]. Mater Sci Eng C 24 (2004) 683-687
    • (2004) Mater Sci Eng C , vol.24 , pp. 683-687
    • TADDEI, E.B.1    HENRIQUES, V.2    SILVA, C.R.M.3    CAIRO, C.4
  • 2
    • 2942613210 scopus 로고    scopus 로고
    • Comparison of metal release from various metallic biomaterials in vitro [J]
    • OKAZAKI Y., and GOTOH E. Comparison of metal release from various metallic biomaterials in vitro [J]. Biomaterials 26 (2005) 11-21
    • (2005) Biomaterials , vol.26 , pp. 11-21
    • OKAZAKI, Y.1    GOTOH, E.2
  • 5
    • 0037411338 scopus 로고    scopus 로고
    • Fatigue performance and cyto-toxicity of low rigidity titanium alloy, Ti-29Nb-13Ta-4.6Zr [J]
    • NIINOMI M. Fatigue performance and cyto-toxicity of low rigidity titanium alloy, Ti-29Nb-13Ta-4.6Zr [J]. Biomaterials 24 (2003) 2673-2683
    • (2003) Biomaterials , vol.24 , pp. 2673-2683
    • NIINOMI, M.1
  • 6
    • 21444459043 scopus 로고    scopus 로고
    • Effect of Ta content on mechanical properties of Ti-30Nb-XTa- 5Zr [J]
    • SAKAGUCHIA N., NIINOMI M., AKAHORI T., TAKEDA J., and TODA H. Effect of Ta content on mechanical properties of Ti-30Nb-XTa- 5Zr [J]. Mat Sci Eng C 25 (2005) 370-376
    • (2005) Mat Sci Eng C , vol.25 , pp. 370-376
    • SAKAGUCHIA, N.1    NIINOMI, M.2    AKAHORI, T.3    TAKEDA, J.4    TODA, H.5
  • 7
    • 34548543902 scopus 로고    scopus 로고
    • Influence of potential on the electrochemical behavior of beta titanium alloys in Hank's solution [J]
    • KARTHEGA M., RAMAN V., and RAJENDRAN N. Influence of potential on the electrochemical behavior of beta titanium alloys in Hank's solution [J]. Acta Biomaterialia 3 (2007) 1019-1023
    • (2007) Acta Biomaterialia , vol.3 , pp. 1019-1023
    • KARTHEGA, M.1    RAMAN, V.2    RAJENDRAN, N.3
  • 8
    • 17144383991 scopus 로고    scopus 로고
    • High strength metatable beta titanium alloys for biomedical applications [J]
    • QAZI J.I., MARQUARDT B., and RACK H.J. High strength metatable beta titanium alloys for biomedical applications [J]. JOM 56 11 (2004) 49-51
    • (2004) JOM , vol.56 , Issue.11 , pp. 49-51
    • QAZI, J.I.1    MARQUARDT, B.2    RACK, H.J.3
  • 9
    • 0032170254 scopus 로고    scopus 로고
    • Titanium alloys in total joint replacements-A materials science perspective [J]
    • LONG M., and RACK H.J. Titanium alloys in total joint replacements-A materials science perspective [J]. Biomaterials 19 (1998) 1621-1639
    • (1998) Biomaterials , vol.19 , pp. 1621-1639
    • LONG, M.1    RACK, H.J.2
  • 10
    • 0026560894 scopus 로고
    • Determinants of stress shielding: Design versus materials versus interface [J]
    • SUMNER D.R., and GALANTE J.O. Determinants of stress shielding: Design versus materials versus interface [J]. Clinical Orthopedics and Related Research 274 (1992) 202-212
    • (1992) Clinical Orthopedics and Related Research , vol.274 , pp. 202-212
    • SUMNER, D.R.1    GALANTE, J.O.2
  • 11
    • 68549124272 scopus 로고    scopus 로고
    • designation draft #3. Standard Specification for Wrought Titanium-35Nb-7Zr-5Ta Alloy for Surgical Implant Applications (UNS R58350) [S]
    • ASTM, ASTM, Philadelphia, PA
    • ASTM designation draft #3. Standard Specification for Wrought Titanium-35Nb-7Zr-5Ta Alloy for Surgical Implant Applications (UNS R58350) [S]. ASTM, Philadelphia, PA, 2000.
    • (2000)
  • 12
    • 33746641332 scopus 로고    scopus 로고
    • Electrochemical impedance spectroscopic characterization of passive film formed over β-Ti-29Nb-13Ta-4.6Zr alloy [J]
    • RAMAN V., NAGARAJAN S., and RAJENDRAN N. Electrochemical impedance spectroscopic characterization of passive film formed over β-Ti-29Nb-13Ta-4.6Zr alloy [J]. Electrochemical Communications 8 (2006) 1309-1314
    • (2006) Electrochemical Communications , vol.8 , pp. 1309-1314
    • RAMAN, V.1    NAGARAJAN, S.2    RAJENDRAN, N.3
  • 13
    • 0033904333 scopus 로고    scopus 로고
    • Phase transformations in Ti-Nb-Ta and Ti-Nb-Ta-Zr alloys [J]
    • TANG X., AHMED T., and RACK H.J. Phase transformations in Ti-Nb-Ta and Ti-Nb-Ta-Zr alloys [J]. Journal of Materials Science 35 (2000) 1805-1811
    • (2000) Journal of Materials Science , vol.35 , pp. 1805-1811
    • TANG, X.1    AHMED, T.2    RACK, H.J.3
  • 14
    • 33748134784 scopus 로고    scopus 로고
    • Microstructural and mechanical characterization of biomedical Ti-Nb-Zr(-Ta) alloys [J]
    • ELIAS L.M., SCHNEIDER S.G., SCHNEIDER S., SILVA H.M., and MALVISI F. Microstructural and mechanical characterization of biomedical Ti-Nb-Zr(-Ta) alloys [J]. Mat Sci Eng A 432 (2006) 108-112
    • (2006) Mat Sci Eng A , vol.432 , pp. 108-112
    • ELIAS, L.M.1    SCHNEIDER, S.G.2    SCHNEIDER, S.3    SILVA, H.M.4    MALVISI, F.5
  • 16
    • 0027670415 scopus 로고
    • Clinical reviews: Particulate debris and failure of total hip replacements [J]
    • JATSY M. Clinical reviews: Particulate debris and failure of total hip replacements [J]. Journal of Applied Biomaterials 4 (1993) 273-276
    • (1993) Journal of Applied Biomaterials , vol.4 , pp. 273-276
    • JATSY, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.