메뉴 건너뛰기




Volumn 3, Issue 6, 2007, Pages 1019-1023

Influence of potential on the electrochemical behaviour of β titanium alloys in Hank's solution

Author keywords

Corrosion; Electrochemical impedance spectroscopy; Hanks solution; Polarization; Titanium

Indexed keywords

BINARY ALLOYS; ELECTROCHEMICAL CORROSION; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; MOLYBDENUM ALLOYS; NIOBIUM ALLOYS; TANTALUM ALLOYS; TITANIUM ALLOYS; ZIRCONIUM ALLOYS;

EID: 34548543902     PISSN: 17427061     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.actbio.2007.02.009     Document Type: Article
Times cited : (134)

References (15)
  • 1
    • 0032170254 scopus 로고    scopus 로고
    • Titanium alloys in total joint replacement - a materials science perspective
    • Long M., and Rack H.J. Titanium alloys in total joint replacement - a materials science perspective. Biomaterials 19 (1998) 1621-1626
    • (1998) Biomaterials , vol.19 , pp. 1621-1626
    • Long, M.1    Rack, H.J.2
  • 2
    • 0023451146 scopus 로고
    • Use of wollastonite in a biomimetic method to promote apatite formation on a Co-Cr-Mo alloy
    • Noort R.V. Use of wollastonite in a biomimetic method to promote apatite formation on a Co-Cr-Mo alloy. J Mater Sci 22 (1987) 3801-3811
    • (1987) J Mater Sci , vol.22 , pp. 3801-3811
    • Noort, R.V.1
  • 3
    • 0000689059 scopus 로고    scopus 로고
    • Recent metallic materials for biomedical applications
    • Niinomi M. Recent metallic materials for biomedical applications. Metal Mater Trans A 33 (2002) 477-486
    • (2002) Metal Mater Trans A , vol.33 , pp. 477-486
    • Niinomi, M.1
  • 4
    • 0027670415 scopus 로고
    • Clinical reviews: particulate debris and failure of total hip replacements
    • Jatsy M. Clinical reviews: particulate debris and failure of total hip replacements. J Appl Biomater 4 (1993) 273-276
    • (1993) J Appl Biomater , vol.4 , pp. 273-276
    • Jatsy, M.1
  • 5
    • 0037411338 scopus 로고    scopus 로고
    • Fatigue performance and cyto-toxicity of low rigidity titanium alloy, Ti-29Nb-13Ta-4.6Zr
    • Niinomi M. Fatigue performance and cyto-toxicity of low rigidity titanium alloy, Ti-29Nb-13Ta-4.6Zr. Biomaterials 24 (2003) 2673-2683
    • (2003) Biomaterials , vol.24 , pp. 2673-2683
    • Niinomi, M.1
  • 6
    • 29944442210 scopus 로고    scopus 로고
    • Corrosion behavior of a low modulus β-Ti-45%Nb alloy for use in medical implants
    • Godley R., Starosvetsky D., and Gotman I. Corrosion behavior of a low modulus β-Ti-45%Nb alloy for use in medical implants. J Mater Sci Mater Med 17 (2006) 63-67
    • (2006) J Mater Sci Mater Med , vol.17 , pp. 63-67
    • Godley, R.1    Starosvetsky, D.2    Gotman, I.3
  • 10
    • 34548522043 scopus 로고    scopus 로고
    • Ahmed TA, Long M, Silverstri J, Ruiz C, Rack HJ. A new low modulus biocompatible titanium alloy. Titanium'95: science and technology; 1996. p. 1760-70.
  • 11
    • 0030218441 scopus 로고    scopus 로고
    • The use of titanium for medical applications in the USA
    • Wang K. The use of titanium for medical applications in the USA. Mater Sci Eng A 213 (1996) 134-137
    • (1996) Mater Sci Eng A , vol.213 , pp. 134-137
    • Wang, K.1
  • 12
    • 34548543034 scopus 로고    scopus 로고
    • Characterization of Ti-Mo alloy for orthopaedic implant applications
    • Medical applications of titanium and its alloys. Brown S.A., and Lemons J.E. (Eds), ASTM, West Conshohocken (PA)
    • Zardiackas L., Mitchell D., and Disegi J. Characterization of Ti-Mo alloy for orthopaedic implant applications. In: Brown S.A., and Lemons J.E. (Eds). Medical applications of titanium and its alloys. ASTM STP 1272 (1996), ASTM, West Conshohocken (PA) 64-67
    • (1996) ASTM STP 1272 , pp. 64-67
    • Zardiackas, L.1    Mitchell, D.2    Disegi, J.3
  • 13
    • 0032832960 scopus 로고    scopus 로고
    • Structure and properties of cast binary Ti-Mo alloys
    • Ho W.F., Ju C.P., and Chem Lin J.H. Structure and properties of cast binary Ti-Mo alloys. Biomaterials 20 (1999) 2115-2122
    • (1999) Biomaterials , vol.20 , pp. 2115-2122
    • Ho, W.F.1    Ju, C.P.2    Chem Lin, J.H.3
  • 14
    • 0842264992 scopus 로고    scopus 로고
    • Electrochemical impedance spectroscopy of passive film formed on implant Ti-6Al-7Nb alloy in Hank's solution
    • Lavos Valereto I.C., and Wolynec S. Electrochemical impedance spectroscopy of passive film formed on implant Ti-6Al-7Nb alloy in Hank's solution. J Mater Sci Mater Med 15 (2004) 55-59
    • (2004) J Mater Sci Mater Med , vol.15 , pp. 55-59
    • Lavos Valereto, I.C.1    Wolynec, S.2
  • 15
    • 33746641332 scopus 로고    scopus 로고
    • Electrochemical impedance spectroscopic characterisation of passive film formed over β-Ti-29Nb-13Ta-4.6Zr alloy
    • Raman V., Nagarajan S., and Rajendran N. Electrochemical impedance spectroscopic characterisation of passive film formed over β-Ti-29Nb-13Ta-4.6Zr alloy. Electrochem Commun 8 (2006) 1309-1314
    • (2006) Electrochem Commun , vol.8 , pp. 1309-1314
    • Raman, V.1    Nagarajan, S.2    Rajendran, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.