Volumn 79, Issue 5, 2009, Pages 908-914

Effects of the taper shape, dual-thread, and length on the mechanical properties of mini-implants

Author keywords

Dual thread; Mechanical; Mini implant; Shape; Torque

Indexed keywords

DENTAL ALLOY; POLYURETHAN; TITANIUM; TITANIUM ALLOY (TIAL6V4);

EID: 68349120477     PISSN: 00033219     EISSN: 00033219     Source Type: Journal    
DOI: 10.2319/071808-374.1     Document Type: Article
Times cited : (53)

References (23)
  • 1
    • 68349090758 scopus 로고    scopus 로고
    • Histological and biomechanical characteristics of orthodontic self-drilling and self-tapping microscrew implants
    • Park HS, Yen S, Jeoung SH. Histological and biomechanical characteristics of orthodontic self-drilling and self-tapping microscrew implants. Korean J Orthod. 2006;36:295-307.
    • (2006) Korean J Orthod. , vol.36 , pp. 295-307
    • Park, H.S.1    Yen, S.2    Jeoung, S.H.3
  • 2
    • 0034585233 scopus 로고    scopus 로고
    • Implant survival to 36 months as related to length and diameter
    • Winkler S, Morris HF, Ochi S. Implant survival to 36 months as related to length and diameter. Ann Periodontol. 2000;5: 22-31.
    • (2000) Ann Periodontol. , vol.5 , pp. 22-31
    • Winkler, S.1    Morris, H.F.2    Ochi, S.3
  • 3
    • 33644639434 scopus 로고    scopus 로고
    • "Safe zonesd": A guide for miniscrew positioning in the maxillary and the mandibular arch
    • Poggio PM, Incorvati C, Velo S, Carano A. "Safe zones": a guide for miniscrew positioning in the maxillary and the mandibular arch. Angle Orthod. 2006;76:191-197.
    • (2006) Angle Orthod. , vol.76 , pp. 191-197
    • Poggio, P.M.1    Incorvati, C.2    Velo, S.3    Carano, A.4
  • 4
    • 68349085015 scopus 로고    scopus 로고
    • Comparison of insertion torque regarding changes in shape, diameter, and length of orthodontic miniscrews
    • Lim SA, Cha JY, Hwang CJ. Comparison of insertion torque regarding changes in shape, diameter, and length of orthodontic miniscrews. Korean J Orthod. 2007;37:87-97.
    • (2007) Korean J Orthod. , vol.37 , pp. 87-97
    • Lim, S.A.1    Cha, J.Y.2    Hwang, C.J.3
  • 5
    • 0346924123 scopus 로고    scopus 로고
    • Influence of implant design on primary fit and stability. An RFA and histological comparison of Mk III and Mk IV Brånemark implants in the dog mandible
    • Rompen E, DaSilva D, Hockers T, Lundgren AK, Gottlow J, Glauser R, Sennerby L. Influence of implant design on primary fit and stability. An RFA and histological comparison of Mk III and Mk IV Brånemark implants in the dog mandible. Appl Osseointegration Res. 2001;2:9-11.
    • (2001) Appl Osseointegration Res. , vol.2 , pp. 9-11
    • Rompen, E.1    DaSilva, D.2    Hockers, T.3    Lundgren, A.K.4    Gottlow, J.5    Glauser, R.6    Sennerby, L.7
  • 6
    • 0032039790 scopus 로고    scopus 로고
    • Marginal bone levels at single tooth implants with a conical fixture design. The influence of surface macro-and microstructure
    • Norton MR. Marginal bone levels at single tooth implants with a conical fixture design. The influence of surface macro-and microstructure. Clin Oral Implants Res. 1998;9:91-99.
    • (1998) Clin Oral Implants Res. , vol.9 , pp. 91-99
    • Norton, M.R.1
  • 7
    • 0024782190 scopus 로고
    • Numerical investigation of the influence of implant shape on stress distribution in the jaw bone
    • Siegele D, Soltesz U. Numerical investigation of the influence of implant shape on stress distribution in the jaw bone. Int J Oral Maxillofac Implants. 1989;4:333-340.
    • (1989) Int J Oral Maxillofac Implants. , vol.4 , pp. 333-340
    • Siegele, D.1    Soltesz, U.2
  • 8
    • 33747118106 scopus 로고    scopus 로고
    • A retrospective analysis of osseotite NT implants in clinical practice: 1-year follow-up
    • Drago CJ, Del Castillo RA. A retrospective analysis of osseotite NT implants in clinical practice: 1-year follow-up. Int J Periodontics Restorative Dent. 2006;26:337-345.
    • (2006) Int J Periodontics Restorative Dent. , vol.26 , pp. 337-345
    • Drago, C.J.1    Del Castillo, R.A.2
  • 9
    • 45849127929 scopus 로고    scopus 로고
    • Comparison of stability between cylindrical and conical type mini-implants
    • Kim JW, Baek SH, Kim TW, Chang YI. Comparison of stability between cylindrical and conical type mini-implants. Angle Orthod. 2008;78:692-698.
    • (2008) Angle Orthod. , vol.78 , pp. 692-698
    • Kim, J.W.1    Baek, S.H.2    Kim, T.W.3    Chang, Y.I.4
  • 10
    • 0042625004 scopus 로고    scopus 로고
    • The implant thread as a retention element in cortical bone: The effect of thread size and thread profile: A finite element study
    • Hansson S, Werke M. The implant thread as a retention element in cortical bone: the effect of thread size and thread profile: a finite element study. J Biomech. 2003;36:1247-1258.
    • (2003) J Biomech. , vol.36 , pp. 1247-1258
    • Hansson, S.1    Werke, M.2
  • 11
    • 0026285722 scopus 로고
    • Relationship between insertion torque and removal torque analyzed in fresh temporal bone
    • Ueda M, Matsuki M, Jacobsson M, Tjellström A. Relationship between insertion torque and removal torque analyzed in fresh temporal bone. Int J Oral Maxillofac Implants. 1991; 6:442-447.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 442-447
    • Ueda, M.1    Matsuki, M.2    Jacobsson, M.3    Tjellström, A.4
  • 12
    • 68349107298 scopus 로고    scopus 로고
    • Torque and mechanical failure of orthodontic micro-implant influenced by implant design parameters
    • Yu W, Kyung HM. Torque and mechanical failure of orthodontic micro-implant influenced by implant design parameters. Korean J Orthod. 2007;37:171-181.
    • (2007) Korean J Orthod. , vol.37 , pp. 171-181
    • Yu, W.1    Kyung, H.M.2
  • 13
    • 17644386834 scopus 로고    scopus 로고
    • Insertional torque of the lumbar pedicle screw during surgery
    • Ozawa T, Takahashi K, Yamagata M, et al. Insertional torque of the lumbar pedicle screw during surgery. J Orthop Sci. 2005;10:133-136.
    • (2005) J Orthop Sci. , vol.10 , pp. 133-136
    • Ozawa, T.1    Takahashi, K.2    Yamagata, M.3
  • 14
    • 0019435541 scopus 로고
    • Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man
    • Albrektsson T, Brånemark PI, Hansson HA, Lindström J. Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand. 1981;52:155-170.
    • (1981) Acta Orthop Scand. , vol.52 , pp. 155-170
    • Albrektsson, T.1    Brånemark, P.I.2    Hansson, H.A.3    Lindström, J.4
  • 15
    • 0031986671 scopus 로고    scopus 로고
    • Evaluating parameters of osseointegrated dental implants using finite element analysis: A two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction
    • Holmgren EP, Seckinger RJ, Kilgren LM, Mante F. Evaluating parameters of osseointegrated dental implants using finite element analysis: a two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction. J Oral Implantol. 1998;24:80-88.
    • (1998) J Oral Implantol. , vol.24 , pp. 80-88
    • Holmgren, E.P.1    Seckinger, R.J.2    Kilgren, L.M.3    Mante, F.4
  • 16
    • 33744458766 scopus 로고    scopus 로고
    • Parameters affecting primary stability of orthodontic mini-implants
    • Wilmes B, Rademacher C, Olthoff G, Drescher D. Parameters affecting primary stability of orthodontic mini-implants. J Orofac Orthop. 2006;67:162-174.
    • (2006) J Orofac Orthop. , vol.67 , pp. 162-174
    • Wilmes, B.1    Rademacher, C.2    Olthoff, G.3    Drescher, D.4
  • 17
    • 56049084734 scopus 로고    scopus 로고
    • Insertion angle impact on primary stability of orthodontic mini-implants
    • Wilmes B, Su YY, Drescher D. Insertion angle impact on primary stability of orthodontic mini-implants. Angle Orthod. 2008;78:1065-1070.
    • (2008) Angle Orthod. , vol.78 , pp. 1065-1070
    • Wilmes, B.1    Su, Y.Y.2    Drescher, D.3
  • 20
    • 40849083718 scopus 로고    scopus 로고
    • Evaluation of the cylinder implant thread height and width: A 3-dimensional finite element analysis
    • Kong L, Hu K, Li D, Song Y, Yang J, Wu Z, Liu B. Evaluation of the cylinder implant thread height and width: a 3-dimensional finite element analysis. Int J Oral Maxillofac Implants. 2008;23:65-74.
    • (2008) Int J Oral Maxillofac Implants. , vol.23 , pp. 65-74
    • Kong, L.1    Hu, K.2    Li, D.3    Song, Y.4    Yang, J.5    Wu, Z.6    Liu, B.7
  • 21
    • 0036184391 scopus 로고    scopus 로고
    • AO self-drilling and self-tapping screws in rat calvarial bone: An ultrastructural study of the implant interface
    • Sowden D, Schmitz JP. AO self-drilling and self-tapping screws in rat calvarial bone: an ultrastructural study of the implant interface. J Oral Maxillofac Surg. 2002;60:294-300.
    • (2002) J Oral Maxillofac Surg. , vol.60 , pp. 294-300
    • Sowden, D.1    Schmitz, J.P.2
  • 22
    • 23344442786 scopus 로고    scopus 로고
    • Histomorphometric and mechanical analyses of the drill-free screw as orthodontic anchorage
    • Kim JW, Ahn SJ, Chang YI. Histomorphometric and mechanical analyses of the drill-free screw as orthodontic anchorage. Am J Orthod Dentofacial Orthop. 2005;128:190-194.
    • (2005) Am J Orthod Dentofacial Orthop. , vol.128 , pp. 190-194
    • Kim, J.W.1    Ahn, S.J.2    Chang, Y.I.3
  • 23
    • 38649127843 scopus 로고    scopus 로고
    • Impact of implant design on primary stability of orthodontic mini-implants
    • Wilmes B, Ottenstreuer S, Su YY, Drescher D, Impact of implant design on primary stability of orthodontic mini-implants: J Orofac Orthop. 2008; 69:42-48.
    • (2008) J Orofac Orthop. , vol.69 , pp. 42-48
    • Wilmes, B.1    Ottenstreuer, S.2    Su, Y.Y.3    Drescher, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.