메뉴 건너뛰기




Volumn 20, Issue 8, 2009, Pages 1721-1728

The early osseointegration of the laser-treated and acid-etched dental implants surface: An experimental study in rabbits

Author keywords

[No Author keywords available]

Indexed keywords

BONE-TO-IMPLANT CONTACT; DENTAL IMPLANTATIONS; DENTAL IMPLANTS; ETCHED SURFACE; EXPERIMENTAL STUDIES; IMPLANT SURFACE; OSSEOINTEGRATION; OSTEOCONDUCTIVITY; POTENTIAL MATERIALS; RABBIT TIBIA; REMOVAL TORQUE; STATISTICALLY SIGNIFICANT DIFFERENCE;

EID: 68149125248     PISSN: 09574530     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10856-009-3730-4     Document Type: Article
Times cited : (26)

References (23)
  • 1
    • 0024201950 scopus 로고    scopus 로고
    • The effects of implant surface topography on the behavior of cells
    • BRUNETTE DM 1998 The effects of implant surface topography on the behavior of cells Int J Oral Maxillofac Implant 3 231 246
    • (1998) Int J Oral Maxillofac Implant , vol.3 , pp. 231-246
    • Brunette, D.M.1
  • 3
    • 68149134576 scopus 로고    scopus 로고
    • Osteroblast interactions with a FRIADENT experimental surface and other microstructured dental implant surfaces
    • Mannheim/Heidelberg, Germany, May 16-17
    • Sanmmons R, Lumbikanonda N, Cantzler P. Osteroblast interactions with a FRIADENT experimental surface and other microstructured dental implant surfaces. Scientific Poster: 10th International FRIADENT symposium, Mannheim/Heidelberg, Germany, May 16-17, 2003.
    • (2003) Scientific Poster: 10th International FRIADENT Symposium
    • Sanmmons, R.1    Lumbikanonda, N.2    Cantzler, P.3
  • 4
    • 0030945623 scopus 로고    scopus 로고
    • Progression of human bone ingrowth into porous-coated implants
    • AA Hofmann RD Bloebaum KN Bachus 1997 Progression of human bone ingrowth into porous-coated implants Acta Orthop Scand 68 161 166
    • (1997) Acta Orthop Scand , vol.68 , pp. 161-166
    • Hofmann, A.A.1    Bloebaum, R.D.2    Bachus, K.N.3
  • 5
    • 20744444530 scopus 로고    scopus 로고
    • Stimulation of directed bone growth at oxidized titanium implants by macroscopic grooves: An in vivo study
    • Hall J, Miranda-burgos P, Sennerby L. Stimulation of directed bone growth at oxidized titanium implants by macroscopic grooves: an in vivo study. Clin Implant Dent Relat Res. 2005;7:76-82.
    • (2005) Clin Implant Dent Relat Res , vol.7 , pp. 76-82
    • Hall, J.1    Miranda-Burgos, P.2    Sennerby, L.3
  • 6
    • 43249118672 scopus 로고    scopus 로고
    • Bone response to modified titanium surface implants in nonhuman primates (Papio ursinus) and humans: Histological evaluation
    • C Mangano V Perrotti G Iezzi A Scarano F Mangano A Piattelli 2008 Bone response to modified titanium surface implants in nonhuman primates (Papio ursinus) and humans: histological evaluation J Oral Implantol 34 1 17 24
    • (2008) J Oral Implantol , vol.34 , Issue.1 , pp. 17-24
    • Mangano, C.1    Perrotti, V.2    Iezzi, G.3    Scarano, A.4    Mangano, F.5    Piattelli, A.6
  • 7
    • 0030087781 scopus 로고    scopus 로고
    • Effect of titanium surface roughness on chondrocyte proliferation, matrix production and differentiation depends on the state of cell maturation
    • Z Schwartz JY Martin DD Dean J Simpson DL Cochran BD Boyan 1996 Effect of titanium surface roughness on chondrocyte proliferation, matrix production and differentiation depends on the state of cell maturation J Biomed Mater Res 30 145 155
    • (1996) J Biomed Mater Res , vol.30 , pp. 145-155
    • Schwartz, Z.1    Martin, J.Y.2    Dean, D.D.3    Simpson, J.4    Cochran, D.L.5    Boyan, B.D.6
  • 8
    • 1842865199 scopus 로고    scopus 로고
    • An in vivo study of bone response to implants topographically modified by laser micromachining
    • Carin Hallgren Henrik Reimers Dinko Chakarov Julie Goldb Ann Wennerberg 2003 An in vivo study of bone response to implants topographically modified by laser micromachining Biomaterials 24 701 709
    • (2003) Biomaterials , vol.24 , pp. 701-709
    • Carin, H.1    Henrik, R.2    Dinko, C.3    Julie, G.4    Ann, W.5
  • 9
    • 0034059429 scopus 로고    scopus 로고
    • Scanning electron microscopical analysis of laser-treated titanium implants surfaces: A comparative study
    • A Gaggl G Schultes WD Müller 2000 Scanning electron microscopical analysis of laser-treated titanium implants surfaces: a comparative study Biomaterials 21 1067 1071
    • (2000) Biomaterials , vol.21 , pp. 1067-1071
    • Gaggl, A.1    Schultes, G.2    Müller, W.D.3
  • 10
    • 0031255466 scopus 로고    scopus 로고
    • Preliminary results of a multicenter study evaluating a chemically enhanced surface for machined commercially pure titanium implants
    • DY Sullivan RL Sherwood TN Mai 1997 Preliminary results of a multicenter study evaluating a chemically enhanced surface for machined commercially pure titanium implants J Prosthet Dent 78 379 386
    • (1997) J Prosthet Dent , vol.78 , pp. 379-386
    • Sullivan, D.Y.1    Sherwood, R.L.2    Mai, T.N.3
  • 11
    • 0003978929 scopus 로고    scopus 로고
    • Ph.D. thesis, Chalmers University of Technology, Department of Applied Physics, Goteborg, Sweden
    • Gold J. Microfabrication for biological applications, Ph.D. thesis, Chalmers University of Technology, Department of Applied Physics, Goteborg, Sweden, 1996.
    • (1996) Microfabrication for Biological Applications
    • Gold, J.1
  • 12
    • 42249097096 scopus 로고    scopus 로고
    • Bone contact around osseointegrated implants: Histologic analysis of a dual-acid-etched surface implant in a diabetic patient
    • C Bugea R Luongo D Di Iorio 2008 Bone contact around osseointegrated implants: histologic analysis of a dual-acid-etched surface implant in a diabetic patient Int J Periodontic Restor Dent 28 145 151
    • (2008) Int J Periodontic Restor Dent , vol.28 , pp. 145-151
    • Bugea, C.1    Luongo, R.2    Di Iorio, D.3
  • 13
    • 38149135055 scopus 로고    scopus 로고
    • Primary stability of turned and acid-etched screw-type implants: A removal torque and histomorphometric study in rabbits
    • Ede L Fernandes IL Unikowski ER Teixeira 2007 Primary stability of turned and acid-etched screw-type implants: a removal torque and histomorphometric study in rabbits Int J Oral Maxillofac Implant 22 886 892
    • (2007) Int J Oral Maxillofac Implant , vol.22 , pp. 886-892
    • Fernandes Ede, L.1    Unikowski, I.L.2    Teixeira, E.R.3
  • 14
    • 0141645495 scopus 로고    scopus 로고
    • A removal torque of the laser-treated titanium implants in rabbit tibia
    • Sung-Am Cho Sang-Kyoo Jung 2003 A removal torque of the laser-treated titanium implants in rabbit tibia Biomaterials 24 4859 4863
    • (2003) Biomaterials , vol.24 , pp. 4859-4863
    • Sung-Am, C.1    Sang-Kyoo, J.2
  • 15
    • 68149119047 scopus 로고    scopus 로고
    • Modified method of making ground section of bone with dental implant
    • Wang Dong-Sheng 2006 Modified method of making ground section of bone with dental implant Chin J Prosthodont Chin J Prosthodont 3 169 170
    • (2006) Chin J Prosthodont Chin J Prosthodont , vol.3 , pp. 169-170
    • Wang, D.1
  • 17
    • 0035180114 scopus 로고    scopus 로고
    • Pore diameter of more than 100 μm is not requisite for bone ingrowth in rabbits
    • IAri Itala O Heimo Ylanen Clifford Ekholm KH Karlsson HT ARO 2000 Pore diameter of more than 100 μm is not requisite for bone ingrowth in rabbits J Biomed Mater Res 58 679 683
    • (2000) J Biomed Mater Res , vol.58 , pp. 679-683
    • Iari, I.1    Heimo, Y.O.2    Clifford, E.3    Karlsson, K.H.4    Aro, H.T.5
  • 18
    • 0344393611 scopus 로고    scopus 로고
    • Roughness induced dynamic changes of wettability of acid etched titanium implant modifications
    • F Rupp L Scheideler D Rehbein D Axmann J Geis-Gerstorfer 2004 Roughness induced dynamic changes of wettability of acid etched titanium implant modifications Biomaterial 25 1429 1438
    • (2004) Biomaterial , vol.25 , pp. 1429-1438
    • Rupp, F.1    Scheideler, L.2    Rehbein, D.3    Axmann, D.4    Geis-Gerstorfer, J.5
  • 19
    • 0004122848 scopus 로고    scopus 로고
    • Department of Biomaterials/Handicap Research, G.oteborg University G.oteborg
    • Wennerberg A. On surfaceroughness, implant incorporation. G.oteborg: Department of Biomaterials/Handicap Research, G.oteborg University; 1996.
    • (1996) On Surfaceroughness, Implant Incorporation
    • Wennerberg, A.1
  • 20
    • 0042388690 scopus 로고    scopus 로고
    • Analysing the optimal value for titanium implant roughness in bone attachment using a tensile test
    • HJ Rønold SP Lyngstadaas JE Ellingsen 2003 Analysing the optimal value for titanium implant roughness in bone attachment using a tensile test Biomaterials 24 4559 4564
    • (2003) Biomaterials , vol.24 , pp. 4559-4564
    • Rønold, H.J.1    Lyngstadaas, S.P.2    Ellingsen, J.E.3
  • 21
    • 33646501397 scopus 로고    scopus 로고
    • Enhanced bone apposition around biofunctionalized sandblasted and acid-etched titanium implant surfaces a histomorphometric study in miniature pigs
    • YVES Germanier Samuele Tosatti Nina Broggini Marcus Textor Daniel Buser 2006 Enhanced bone apposition around biofunctionalized sandblasted and acid-etched titanium implant surfaces a histomorphometric study in miniature pigs Clin Oral Impl Res 17 251 257
    • (2006) Clin Oral Impl Res , vol.17 , pp. 251-257
    • Yves, G.1    Samuele, T.2    Nina, B.3    Marcus, T.4    Daniel, B.5
  • 22
    • 68149152249 scopus 로고    scopus 로고
    • Healing sequeces during tissue integration of ITI implants-analysis of early morphogenesis
    • Fuzhou, September 9
    • Lang Niklaus P. Healing sequeces during tissue integration of ITI implants-analysis of early morphogenesis. Congress, Fuzhou, September 9, 2007.
    • (2007) Congress
    • Lang Niklaus, P.1
  • 23
    • 0038722654 scopus 로고    scopus 로고
    • The removal torque of titanium screw inserted in rabbit tibia treated by dual acid etching
    • Sung-Am Cho Kyung-Tae Park 2003 The removal torque of titanium screw inserted in rabbit tibia treated by dual acid etching Biomaterials 24 3611 3617
    • (2003) Biomaterials , vol.24 , pp. 3611-3617
    • Sung-Am, C.1    Kyung-Tae, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.