메뉴 건너뛰기




Volumn 30, Issue 2, 2009, Pages 461-465

Active two-channel 0.035″ guidewire for interventional cardiovascular MRI

Author keywords

Active instrument; Catheterization methods; Equipment design; Interventional magnetic resonance imaging methods

Indexed keywords

ANIMAL EXPERIMENT; ANTENNA; ARTICLE; CARDIOVASCULAR SYSTEM; CONTROLLED STUDY; DIPOLE; IN VITRO STUDY; IN VIVO STUDY; INTERVENTIONAL MAGNETIC RESONANCE IMAGING; NONHUMAN; PERFORMANCE; PRIORITY JOURNAL; RIGIDITY; SWINE; TORQUE; VISIBILITY; X RAY;

EID: 68049117366     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.21844     Document Type: Article
Times cited : (19)

References (12)
  • 1
    • 27744570790 scopus 로고    scopus 로고
    • Cardiovascular interventional magnetic resonance imaging
    • DOI 10.1161/CIRCULATIONAHA.104.531368
    • Lederman RJ. Cardiovascular interventional magnetic resonance imaging. Circulation 2005;112:3009-3017. (Pubitemid 41612305)
    • (2005) Circulation , vol.112 , Issue.19 , pp. 3009-3017
    • Lederman, R.J.1
  • 4
    • 36849062571 scopus 로고    scopus 로고
    • A catheter tracking method using reverse polarization for MR-guided interventions
    • DOI 10.1002/mrm.21419
    • Celik H, Uluturk A, Tali T, Atalar E. A catheter tracking method using reverse polarization for MR-guided interventions. Magn Reson Med 2007;58:1224-1231. (Pubitemid 350234209)
    • (2007) Magnetic Resonance in Medicine , vol.58 , Issue.6 , pp. 1224-1231
    • Celik, H.1    Uluturk, A.2    Tali, T.3    Atalar, E.4
  • 7
    • 20044375729 scopus 로고    scopus 로고
    • Invasive human magnetic resonance imaging: Feasibility during revascularization in a combined XMR suite
    • Dick AJ, Raman VK, Raval AN, et al. Invasive human magnetic resonance imaging: feasibility during revascularization in a combined XMR suite. Catheter Cardiovasc Interv 2005;64:265-274.
    • (2005) Catheter Cardiovasc Interv , vol.64 , pp. 265-274
    • Dick, A.J.1    Raman, V.K.2    Raval, A.N.3
  • 8
    • 0043093791 scopus 로고    scopus 로고
    • Intravascular extended sensitivity (IVES) MRI antennas
    • DOI 10.1002/mrm.10506
    • Susil RC, Yeung CJ, Atalar E. Intravascular extended sensitivity (IVES) MRI antennas. Magn Reson Med 2003;50:383-390. (Pubitemid 36950858)
    • (2003) Magnetic Resonance in Medicine , vol.50 , Issue.2 , pp. 383-390
    • Susil, R.C.1    Yeung, C.J.2    Atalar, E.3
  • 10
    • 68049135516 scopus 로고    scopus 로고
    • Available at: Last accessed December 3, 2008
    • U.S. FDA CDRH (January 1, 1995), Coronary and Cerebrovascular Guidewire Guidance. Available at: http://www.accessdata.fda. gov/scripts/cdrh/cfdocs/ cfggp/search.cfm. Last accessed December 3, 2008.
  • 12


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.