메뉴 건너뛰기




Volumn 36, Issue 4, 1996, Pages 596-605

High resolution intravascular MRI and MRS by using a catheter receiver coil

Author keywords

atherosclerosis; intravascular MRI; MR catheter coil; MRI of arterial wall

Indexed keywords

CATHETERS; CHEMICAL SHIFT; DISEASES; MAGNETIC RESONANCE IMAGING; SIGNAL TO NOISE RATIO;

EID: 0029759892     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.1910360415     Document Type: Article
Times cited : (152)

References (28)
  • 3
    • 0026654969 scopus 로고
    • Intravascular ultrasound: A histological study of vessel during life
    • B. F. Waller, C. A. Pinkerton, J. D. Slack, Intravascular ultrasound: a histological study of vessel during life. Circulation 85, 2305-2310 (1992).
    • (1992) Circulation , vol.85 , pp. 2305-2310
    • Waller, B.F.1    Pinkerton, C.A.2    Slack, J.D.3
  • 4
    • 0025950870 scopus 로고
    • Nuclear magnetic resonance microscopy of atheroma in human coronary arteries
    • J. D. Pearlman, J. F. Southern, J. L. Ackerman, Nuclear magnetic resonance microscopy of atheroma in human coronary arteries. Angiology 42, 726-733 (1991).
    • (1991) Angiology , vol.42 , pp. 726-733
    • Pearlman, J.D.1    Southern, J.F.2    Ackerman, J.L.3
  • 10
    • 0025893293 scopus 로고
    • Magnetic resonance imaging of lipid deposits in human atheroma via a stimulated-echo diffusion-weighted technique
    • M. I. Altbach, M. A. Mattingly, M. F. Brown, A. F. Gmitro, Magnetic resonance imaging of lipid deposits in human atheroma via a stimulated-echo diffusion-weighted technique. Magn. Reson. Med. 20, 319-326 (1991).
    • (1991) Magn. Reson. Med. , vol.20 , pp. 319-326
    • Altbach, M.I.1    Mattingly, M.A.2    Brown, M.F.3    Gmitro, A.F.4
  • 15
    • 0027399141 scopus 로고
    • Real-time position monitoring of invasive devices using magnetic resonance
    • C. L. Dumoulin, S. P. Souza, R. D. Darrow, Real-time position monitoring of invasive devices using magnetic resonance. Magn. Reson. Med. 29, 411-415 (1993).
    • (1993) Magn. Reson. Med. , vol.29 , pp. 411-415
    • Dumoulin, C.L.1    Souza, S.P.2    Darrow, R.D.3
  • 16
    • 10144245526 scopus 로고
    • V. G. K. Catheters and guide wires for use in an echo-planar MR floroscopy system
    • V. D. Koechli, G. C. McKinnon, E. Hofmann, V. G. K. Catheters and guide wires for use in an echo-planar MR floroscopy system, Radiology 189(P) 319 (1993).
    • (1993) Radiology , vol.189 P , pp. 319
    • Koechli, V.D.1    McKinnon, G.C.2    Hofmann, E.3
  • 17
    • 0021285166 scopus 로고
    • In vivo 31P nuclear magnetic resonance measurements in cacine heart using a catheter-coil
    • H. L. Kantor, R. W. Briggs, R. S. Balaban, In vivo 31P nuclear magnetic resonance measurements in cacine heart using a catheter-coil. Circ. Res. 55, 261-266 (1984).
    • (1984) Circ. Res. , vol.55 , pp. 261-266
    • Kantor, H.L.1    Briggs, R.W.2    Balaban, R.S.3
  • 19
    • 0026534199 scopus 로고
    • Intravascular (catheter) NMR receiver probe: Preliminary design analysis and application to canine iliofemoral imaging
    • G. C. Hurst, J. Hua, J. L. Duerk, A. M. Cohen, Intravascular (catheter) NMR receiver probe: preliminary design analysis and application to canine iliofemoral imaging. Magn. Reson. Med. 24, 343-357 (1992).
    • (1992) Magn. Reson. Med. , vol.24 , pp. 343-357
    • Hurst, G.C.1    Hua, J.2    Duerk, J.L.3    Cohen, A.M.4
  • 20
    • 0028488906 scopus 로고
    • Intravascular MR imaging in a porcine animal model
    • A. J. Martin, R. M. Henkelman, Intravascular MR imaging in a porcine animal model. Magn. Reson. Med. 32, 224-229 (1994).
    • (1994) Magn. Reson. Med. , vol.32 , pp. 224-229
    • Martin, A.J.1    Henkelman, R.M.2
  • 23
    • 0003468615 scopus 로고
    • Interactions between Electromagnetic Fields and Cells
    • A. Chiabrera, C. Nicolini, H. P. Schwan, Eds., "Interactions between Electromagnetic Fields and Cells," vol. 97, NATO ASI Series, 1985.
    • (1985) NATO ASI Series , vol.97
    • Chiabrera, A.1    Nicolini, C.2    Schwan, H.P.3
  • 24
    • 85035181990 scopus 로고
    • AIN Plastics, Inc.
    • "Catalog 93" AIN Plastics, Inc., 1993.
    • (1993) Catalog 93
  • 25
  • 26
    • 0029294178 scopus 로고
    • The signal-to-noise ratio of nuclear magnetic resonance surface coils and application to a lossy dielectric cylinder model - Part 1: Theory
    • H. Vesselle, R. E. Collin, The signal-to-noise ratio of nuclear magnetic resonance surface coils and application to a lossy dielectric cylinder model - part 1: theory. IEEE Trans. Biomed. Eng. 42, 497-506 (1995).
    • (1995) IEEE Trans. Biomed. Eng. , vol.42 , pp. 497-506
    • Vesselle, H.1    Collin, R.E.2
  • 28
    • 0001301865 scopus 로고
    • Electronic decoupling of surface-coil receivers for NMR imaging and spectroscopy
    • W. A. Edelstein, C. J. Hardy, O. M. Mueller, Electronic decoupling of surface-coil receivers for NMR imaging and spectroscopy. J. Magn. Reson. Imaging 67, 156-161 (1986).
    • (1986) J. Magn. Reson. Imaging , vol.67 , pp. 156-161
    • Edelstein, W.A.1    Hardy, C.J.2    Mueller, O.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.