메뉴 건너뛰기




Volumn 58, Issue 6, 2007, Pages 1224-1231

A catheter tracking method using reverse polarization for MR-guided interventions

Author keywords

Catheter coils; Inductive coupling; Interventional device tracking; Interventional MRA; Wireless active instrument visualization

Indexed keywords

ELECTRIC CONNECTORS; ELECTROMAGNETIC INDUCTION; POLARIZATION; VISUALIZATION;

EID: 36849062571     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.21419     Document Type: Article
Times cited : (25)

References (16)
  • 1
    • 0028288337 scopus 로고
    • Vascular interventions guided by ultrafast MR-imaging - evaluation of different materials
    • Kochli VD, McKinnon GC, Hofmann E, Vonschulthess GK. Vascular interventions guided by ultrafast MR-imaging - evaluation of different materials. Magn Reson Med 1994;31:309-314.
    • (1994) Magn Reson Med , vol.31 , pp. 309-314
    • Kochli, V.D.1    McKinnon, G.C.2    Hofmann, E.3    Vonschulthess, G.K.4
  • 3
    • 0031023708 scopus 로고    scopus 로고
    • Intravascular magnetic resonance imaging using a loopless catheter antenna
    • Ocali O, Atalar E. Intravascular magnetic resonance imaging using a loopless catheter antenna. Magn Reson Med 1997;37:112-118.
    • (1997) Magn Reson Med , vol.37 , pp. 112-118
    • Ocali, O.1    Atalar, E.2
  • 4
    • 12844269349 scopus 로고    scopus 로고
    • Interventional magnetic resonance angiography with no strings attached: Wireless active catheter visualization
    • Quick HH, Zenge MO, Kuehl H, Kaiser G, Aker S, Massing S, Bosk S, Ladd ME. Interventional magnetic resonance angiography with no strings attached: Wireless active catheter visualization. Magn Reson Med 2005;53:446-455.
    • (2005) Magn Reson Med , vol.53 , pp. 446-455
    • Quick, H.H.1    Zenge, M.O.2    Kuehl, H.3    Kaiser, G.4    Aker, S.5    Massing, S.6    Bosk, S.7    Ladd, M.E.8
  • 5
    • 0029781333 scopus 로고    scopus 로고
    • Tuned fiducial markers to identify body locations with minimal perturbation of tissue magnetization
    • Burl M, Coutts GA, Young IR. Tuned fiducial markers to identify body locations with minimal perturbation of tissue magnetization. Magn Reson Med 1996;36:491-493.
    • (1996) Magn Reson Med , vol.36 , pp. 491-493
    • Burl, M.1    Coutts, G.A.2    Young, I.R.3
  • 9
    • 46549092488 scopus 로고
    • An efficient, highly homogenous radiofrequency coil for whole-body NMR imaging at 1.5 T
    • Hayes CE, Edelstein WA, Schenck JF, Mueller OM, Eash M. An efficient, highly homogenous radiofrequency coil for whole-body NMR imaging at 1.5 T. J Magn Reson 1985;63:622-628.
    • (1985) J Magn Reson , vol.63 , pp. 622-628
    • Hayes, C.E.1    Edelstein, W.A.2    Schenck, J.F.3    Mueller, O.M.4    Eash, M.5
  • 10
    • 0036136666 scopus 로고    scopus 로고
    • RF safety of wires in interventional MRI: Using a safety index
    • Yeung CJ, Susil RC, Atalar E. RF safety of wires in interventional MRI: using a safety index. Magn Reson Med 2002;47:187-193.
    • (2002) Magn Reson Med , vol.47 , pp. 187-193
    • Yeung, C.J.1    Susil, R.C.2    Atalar, E.3
  • 13
    • 0027399141 scopus 로고
    • Real-time position monitoring of invasive devices using magnetic resonance
    • Dumoulin CL, Souza SP, Darrow RD. Real-time position monitoring of invasive devices using magnetic resonance. Magn Reson Med 1993;29:411-415.
    • (1993) Magn Reson Med , vol.29 , pp. 411-415
    • Dumoulin, C.L.1    Souza, S.P.2    Darrow, R.D.3
  • 15
    • 19544372445 scopus 로고    scopus 로고
    • Magnetic resonance angiography of rat spinal cord at 9.4 T: A feasibility study
    • Bilgen M, Al-Hafez B, He YY, Brooks WM. Magnetic resonance angiography of rat spinal cord at 9.4 T: a feasibility study. Magn Reson Med 2005;53:1459-1461.
    • (2005) Magn Reson Med , vol.53 , pp. 1459-1461
    • Bilgen, M.1    Al-Hafez, B.2    He, Y.Y.3    Brooks, W.M.4
  • 16
    • 36849039810 scopus 로고    scopus 로고
    • Celik H, Quick H, Zenge M, Atalar E. Wireless active catheter tracking method using reversed polarization: implementation of 12-channels phased array coil. ESMRMB, Warsaw, Poland; Abstract 258, 2006.
    • Celik H, Quick H, Zenge M, Atalar E. Wireless active catheter tracking method using reversed polarization: implementation of 12-channels phased array coil. ESMRMB, Warsaw, Poland; Abstract 258, 2006.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.