메뉴 건너뛰기




Volumn 24, Issue 3, 2009, Pages 322-328

Assessing the predictive value of the bispectral index vs patient state index on clinical assessment of sedation in postoperative cardiac surgery patients

Author keywords

Bispectral index; Critically ill; Patient state index; Ramsay sedation scale; Sedation

Indexed keywords

MORPHINE; PROPOFOL;

EID: 67949121849     PISSN: 08839441     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrc.2008.11.004     Document Type: Article
Times cited : (20)

References (26)
  • 1
    • 0036152552 scopus 로고    scopus 로고
    • Clinical practice guidelines for the sustained use of sedatives and analgesics in the critically ill adult
    • Jacobi J., Fraser G.L., Coursin D.B., et al. Clinical practice guidelines for the sustained use of sedatives and analgesics in the critically ill adult. Crit Care Med 30 (2002) 119-141
    • (2002) Crit Care Med , vol.30 , pp. 119-141
    • Jacobi, J.1    Fraser, G.L.2    Coursin, D.B.3
  • 2
    • 34247160798 scopus 로고    scopus 로고
    • Sedation and analgesia in the critically ill adult
    • Fraser G.L., and Riker R.R. Sedation and analgesia in the critically ill adult. Curr Opin Anaesthesiol 20 (2007) 119-123
    • (2007) Curr Opin Anaesthesiol , vol.20 , pp. 119-123
    • Fraser, G.L.1    Riker, R.R.2
  • 3
    • 0034653987 scopus 로고    scopus 로고
    • Sedation in the intensive care unit: a systematic review
    • Ostermann M.E., Keenan S.P., Seiferling R.A., et al. Sedation in the intensive care unit: a systematic review. JAMA 283 (2000) 1451-1459
    • (2000) JAMA , vol.283 , pp. 1451-1459
    • Ostermann, M.E.1    Keenan, S.P.2    Seiferling, R.A.3
  • 4
    • 0034033364 scopus 로고    scopus 로고
    • Using and understanding sedation scoring systems: a systematic review
    • De Jonghe B., Cook D., Appere-De-Vecchi C., et al. Using and understanding sedation scoring systems: a systematic review. Intensive Care Med 26 (2000) 275-285
    • (2000) Intensive Care Med , vol.26 , pp. 275-285
    • De Jonghe, B.1    Cook, D.2    Appere-De-Vecchi, C.3
  • 5
    • 0033860886 scopus 로고    scopus 로고
    • Instruments for monitoring intensive care unit sedation
    • Carrasco G. Instruments for monitoring intensive care unit sedation. Critical Care 4 (2000) 217-225
    • (2000) Critical Care , vol.4 , pp. 217-225
    • Carrasco, G.1
  • 7
    • 67949096295 scopus 로고    scopus 로고
    • Available online at: [Accessed October 2, 2007]
    • Patient State Index. Available online at:. www.hospira.com/Products/psa4000.aspx [Accessed October 2, 2007]
    • Patient State Index
  • 8
    • 28844440367 scopus 로고    scopus 로고
    • Role of brain function monitoring in critical care and perioperative settings
    • Ramsay M.A.E. Role of brain function monitoring in critical care and perioperative settings. Semin Anesth Perioper Med Pain 24 (2005) 195-202
    • (2005) Semin Anesth Perioper Med Pain , vol.24 , pp. 195-202
    • Ramsay, M.A.E.1
  • 9
    • 0016400110 scopus 로고
    • Controlled sedation with alphaxalone-alphadolone
    • Ramsay M.A., Savege T.M., Simpson B.R., et al. Controlled sedation with alphaxalone-alphadolone. Br Med J 2 (1974) 656-659
    • (1974) Br Med J , vol.2 , pp. 656-659
    • Ramsay, M.A.1    Savege, T.M.2    Simpson, B.R.3
  • 10
    • 0036309803 scopus 로고    scopus 로고
    • How reliable is the bispectral index in critically ill patients? A prospective, comparative, single-blinded observer study
    • Nasraway S.A., Wu E.C., Kelleher R.M., et al. How reliable is the bispectral index in critically ill patients? A prospective, comparative, single-blinded observer study. Crit Care Med 30 (2002) 1483-1487
    • (2002) Crit Care Med , vol.30 , pp. 1483-1487
    • Nasraway, S.A.1    Wu, E.C.2    Kelleher, R.M.3
  • 11
    • 0031648072 scopus 로고    scopus 로고
    • Use of continuous bispectral EEG monitoring to assess depth of sedation in ICU patients
    • De-Deyne C.D., Struys M., Decruyenaere J., et al. Use of continuous bispectral EEG monitoring to assess depth of sedation in ICU patients. Intensive Care Med 24 (1998) 1294-1298
    • (1998) Intensive Care Med , vol.24 , pp. 1294-1298
    • De-Deyne, C.D.1    Struys, M.2    Decruyenaere, J.3
  • 12
    • 0036915141 scopus 로고    scopus 로고
    • Bispectral index in ICU: correlation with Ramsay Score on assessment of sedation level
    • Mondello E., Siliotti R., Noto G., et al. Bispectral index in ICU: correlation with Ramsay Score on assessment of sedation level. J Clin Monit Comput 17 (2002) 271-277
    • (2002) J Clin Monit Comput , vol.17 , pp. 271-277
    • Mondello, E.1    Siliotti, R.2    Noto, G.3
  • 13
    • 0036255632 scopus 로고    scopus 로고
    • Bispectral index-guided sedation with dexmedetomidine in intensive care: a prospective, randomized, double blind, placebo-controlled phase II study
    • Triltsch A.E., Welte M., Von Homeyer P., et al. Bispectral index-guided sedation with dexmedetomidine in intensive care: a prospective, randomized, double blind, placebo-controlled phase II study. Crit Care Med 30 (2002) 1007-1014
    • (2002) Crit Care Med , vol.30 , pp. 1007-1014
    • Triltsch, A.E.1    Welte, M.2    Von Homeyer, P.3
  • 14
    • 34250663121 scopus 로고    scopus 로고
    • Bispectral index as a predictor of sedation depth during isoflurane or midazolam sedation in ICU patients
    • Sackey P.V., Radell P.J., Granath F., et al. Bispectral index as a predictor of sedation depth during isoflurane or midazolam sedation in ICU patients. Anesth Intensive Care 35 (2007) 348-356
    • (2007) Anesth Intensive Care , vol.35 , pp. 348-356
    • Sackey, P.V.1    Radell, P.J.2    Granath, F.3
  • 15
    • 14944340269 scopus 로고    scopus 로고
    • Comparison of two bispectral index algorithms in monitoring sedation in postoperative intensive care patients
    • Tonner P.H., Wei C., Bein B., et al. Comparison of two bispectral index algorithms in monitoring sedation in postoperative intensive care patients. Crit Care Med 33 (2005) 580-584
    • (2005) Crit Care Med , vol.33 , pp. 580-584
    • Tonner, P.H.1    Wei, C.2    Bein, B.3
  • 16
    • 0034010890 scopus 로고    scopus 로고
    • Bispectral index increases and decreases are not always signs of inadequate anesthesia
    • Guignard B., and Chauvin M. Bispectral index increases and decreases are not always signs of inadequate anesthesia. Anesthesiology 92 (2000) 903
    • (2000) Anesthesiology , vol.92 , pp. 903
    • Guignard, B.1    Chauvin, M.2
  • 17
    • 33645092899 scopus 로고    scopus 로고
    • Role of the bispectral index in sedation monitoring in the ICU
    • LeBlanc J.M., Dasta J.F., and Kane-Gill S.L. Role of the bispectral index in sedation monitoring in the ICU. Ann Pharmacother. 40 (2006) 490-500
    • (2006) Ann Pharmacother. , vol.40 , pp. 490-500
    • LeBlanc, J.M.1    Dasta, J.F.2    Kane-Gill, S.L.3
  • 18
    • 1342310811 scopus 로고    scopus 로고
    • Patient State Index (PSI) measures depth of sedation in intensive care patients
    • Schneider G., Heglmeier S., Schneider J., et al. Patient State Index (PSI) measures depth of sedation in intensive care patients. Intensive Care Med 30 (2004) 213-216
    • (2004) Intensive Care Med , vol.30 , pp. 213-216
    • Schneider, G.1    Heglmeier, S.2    Schneider, J.3
  • 19
    • 33644945971 scopus 로고    scopus 로고
    • Patient State Index correlates with Ramsay sedation score in ICU patients
    • [abstr]
    • Ramsay M.A., Huddleston P., Hamman B., et al. Patient State Index correlates with Ramsay sedation score in ICU patients. Anesthesiology 101 (2004) A338 [abstr]
    • (2004) Anesthesiology , vol.101
    • Ramsay, M.A.1    Huddleston, P.2    Hamman, B.3
  • 20
    • 67949097772 scopus 로고    scopus 로고
    • Comparison of depth of sedation measured by PSA 4000 and Richmond Agitation-Sedation Scale (RASS)
    • [abstr]
    • Sessler C.N., Kollef M., Hamilton A., et al. Comparison of depth of sedation measured by PSA 4000 and Richmond Agitation-Sedation Scale (RASS). Chest 128 4 (2005) 151S [abstr]
    • (2005) Chest , vol.128 , Issue.4
    • Sessler, C.N.1    Kollef, M.2    Hamilton, A.3
  • 21
    • 0036894508 scopus 로고    scopus 로고
    • A comparison of Patient State Index and bispectral index values during the perioperative period
    • Chen X., Tang J., White P.F., et al. A comparison of Patient State Index and bispectral index values during the perioperative period. Anesth Analg 95 (2002) 1669-1674
    • (2002) Anesth Analg , vol.95 , pp. 1669-1674
    • Chen, X.1    Tang, J.2    White, P.F.3
  • 22
    • 30144440591 scopus 로고    scopus 로고
    • Comparison of electrophysiologic monitors with clinical assessment of level of sedation
    • Chisholm C.J., Zurica J., Mironov D., et al. Comparison of electrophysiologic monitors with clinical assessment of level of sedation. Mayo Clin Proc. 81 (2006) 46-52
    • (2006) Mayo Clin Proc. , vol.81 , pp. 46-52
    • Chisholm, C.J.1    Zurica, J.2    Mironov, D.3
  • 23
    • 0034013885 scopus 로고    scopus 로고
    • What does the Bispectral EEG Index monitor?
    • [editorial]
    • Chan M.T., and Gin T. What does the Bispectral EEG Index monitor?. Eur J Anaesthesiol 17 (2000) 146-148 [editorial]
    • (2000) Eur J Anaesthesiol , vol.17 , pp. 146-148
    • Chan, M.T.1    Gin, T.2
  • 24
    • 0032911791 scopus 로고    scopus 로고
    • Pacer-induced artifact in the bispectral analysis for the electro-encephalogram
    • Gallagher J.D. Pacer-induced artifact in the bispectral analysis for the electro-encephalogram. Anesthesiology 90 (1999) 636
    • (1999) Anesthesiology , vol.90 , pp. 636
    • Gallagher, J.D.1
  • 25
    • 0033866585 scopus 로고    scopus 로고
    • The effect of intravenous epinephrine on the bispectral index and sedation
    • Andrzejowski J., Sleigh J.W., Johnson A.T., et al. The effect of intravenous epinephrine on the bispectral index and sedation. Anaesthesia 55 (2000) 761-763
    • (2000) Anaesthesia , vol.55 , pp. 761-763
    • Andrzejowski, J.1    Sleigh, J.W.2    Johnson, A.T.3
  • 26
    • 0034096764 scopus 로고    scopus 로고
    • Electromyographic activity falsely elevates the bispectral index
    • Bruhn J., Bouillon T.W., and Shafer S.L. Electromyographic activity falsely elevates the bispectral index. Anesthesiology 92 (2000) 1485-1487
    • (2000) Anesthesiology , vol.92 , pp. 1485-1487
    • Bruhn, J.1    Bouillon, T.W.2    Shafer, S.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.