메뉴 건너뛰기




Volumn 81, Issue 1, 2006, Pages 46-52

Comparison of electrophysiologic monitors with clinical assessment of level of sedation

Author keywords

[No Author keywords available]

Indexed keywords

FENTANYL; MIDAZOLAM; PROPOFOL;

EID: 30144440591     PISSN: 00256196     EISSN: None     Source Type: Journal    
DOI: 10.4065/81.1.46     Document Type: Article
Times cited : (69)

References (35)
  • 1
    • 0036204179 scopus 로고    scopus 로고
    • Practice guidelines for sedation and analgesia by non-anesthesiologists
    • American Society of Anesthesiologists Task Force on Sedation and Analgesia by Non-Anesthesiologists. Practice guidelines for sedation and analgesia by non-anesthesiologists. Anesthesiology. 2002;96:1004-1017.
    • (2002) Anesthesiology , vol.96 , pp. 1004-1017
  • 3
    • 0032814036 scopus 로고    scopus 로고
    • Prospective evaluation of the Sedation-Agitation Scale for adult critically ill patients
    • Riker RR, Picard JT, Fraser GL. Prospective evaluation of the Sedation-Agitation Scale for adult critically ill patients. Crit Care Med. 1999;27:1325-1329.
    • (1999) Crit Care Med , vol.27 , pp. 1325-1329
    • Riker, R.R.1    Picard, J.T.2    Fraser, G.L.3
  • 4
    • 0025046841 scopus 로고
    • Validity and reliability of the Observer's Assessment of Alertness/Sedation Scale: Study with intravenous midazolam
    • Chernik DA, Gillings D, Laine H, et al. Validity and reliability of the Observer's Assessment of Alertness/Sedation Scale: study with intravenous midazolam. J Clin Psychopharmacol. 1990;10:244-251.
    • (1990) J Clin Psychopharmacol , vol.10 , pp. 244-251
    • Chernik, D.A.1    Gillings, D.2    Laine, H.3
  • 5
    • 0035190922 scopus 로고    scopus 로고
    • Monitoring sedation, agitation, analgesia, and delirium in critically ill adult patients
    • Fraser GL, Riker RR. Monitoring sedation, agitation, analgesia, and delirium in critically ill adult patients. Crit Care Clin. 2001;17:967-987.
    • (2001) Crit Care Clin , vol.17 , pp. 967-987
    • Fraser, G.L.1    Riker, R.R.2
  • 6
    • 20444502983 scopus 로고    scopus 로고
    • Large-scale implementation of sedation and delirium monitoring in the intensive care unit: A report from two medical centers
    • Pun BT, Gordon SM, Peterson JF, et al. Large-scale implementation of sedation and delirium monitoring in the intensive care unit: a report from two medical centers. Crit Care Med. 2005;33:1199-1205.
    • (2005) Crit Care Med , vol.33 , pp. 1199-1205
    • Pun, B.T.1    Gordon, S.M.2    Peterson, J.F.3
  • 7
    • 0031028285 scopus 로고    scopus 로고
    • Electroencephalographic bispectral index correlates with intraoperative recall and depth of propofol-induced sedation
    • Liu J, Singh H, White PF. Electroencephalographic bispectral index correlates with intraoperative recall and depth of propofol-induced sedation. Anesth Analg. 1997;84:185-189.
    • (1997) Anesth Analg , vol.84 , pp. 185-189
    • Liu, J.1    Singh, H.2    White, P.F.3
  • 8
    • 0027705106 scopus 로고
    • Environmental monitoring, assessment and prediction of change
    • El-Shaarawi A. Environmental monitoring, assessment and prediction of change. Environmetrics. 1981;4:381-398.
    • (1981) Environmetrics , vol.4 , pp. 381-398
    • El-Shaarawi, A.1
  • 9
    • 0021639934 scopus 로고
    • A nonparametric trend test for seasonal data with serial dependence
    • Hirsch R, Slack J. A nonparametric trend test for seasonal data with serial dependence. Water Resources Research. 1984;20:727-732.
    • (1984) Water Resources Research , vol.20 , pp. 727-732
    • Hirsch, R.1    Slack, J.2
  • 10
    • 0029945017 scopus 로고    scopus 로고
    • A measure of association for assessing prediction accuracy that is a generalization of non-parametric ROC area
    • Smith WD, Dutton RC, Smith NT. A measure of association for assessing prediction accuracy that is a generalization of non-parametric ROC area. Stat Med. 1996;15:1199-1215.
    • (1996) Stat Med , vol.15 , pp. 1199-1215
    • Smith, W.D.1    Dutton, R.C.2    Smith, N.T.3
  • 12
    • 0000647028 scopus 로고
    • Bispectral analysis of EEG may predict anesthetic depth during narcotic induction
    • Kearse L, Saini V, deBros F, Chamoun N. Bispectral analysis of EEG may predict anesthetic depth during narcotic induction [abstract]. Anesthesiology. 1991;75(suppl 3A):A175.
    • (1991) Anesthesiology , vol.75 , Issue.SUPPL. 3A
    • Kearse, L.1    Saini, V.2    DeBros, F.3    Chamoun, N.4
  • 13
    • 0030963250 scopus 로고    scopus 로고
    • A multicenter study of bispectral electroencephalogram analysis for monitoring anesthetic effect
    • Sebel PS, Lang E, Rampil IJ, et al. A multicenter study of bispectral electroencephalogram analysis for monitoring anesthetic effect. Anesth Analg. 1997;84:891-899.
    • (1997) Anesth Analg , vol.84 , pp. 891-899
    • Sebel, P.S.1    Lang, E.2    Rampil, I.J.3
  • 15
    • 0036300626 scopus 로고    scopus 로고
    • Patient State Index: Titration of delivery and recovery from propofol, alfentanil, and nitrous oxide anesthesia
    • Drover DR, Lemmens HJ, Pierce ET, et al. Patient State Index: titration of delivery and recovery from propofol, alfentanil, and nitrous oxide anesthesia. Anesthesiology. 2002;97:82-89.
    • (2002) Anesthesiology , vol.97 , pp. 82-89
    • Drover, D.R.1    Lemmens, H.J.2    Pierce, E.T.3
  • 16
    • 0034872926 scopus 로고    scopus 로고
    • Intraoperative awareness and memory: It doesn't just happen to somebody else
    • Billard V, Cheikh M. Intraoperative awareness and memory: it doesn't just happen to somebody else [in French] [editorial]. Ann Fr Anesth Reanim. 2001;20:583-586.
    • (2001) Ann Fr Anesth Reanim , vol.20 , pp. 583-586
    • Billard, V.1    Cheikh, M.2
  • 17
    • 0036894508 scopus 로고    scopus 로고
    • A comparison of patient state index and bispectral index values during the perioperative period
    • Chen X, Tang J, White PF, et al. A comparison of patient state index and bispectral index values during the perioperative period. Anesth Analg. 2002;95:1669-1674.
    • (2002) Anesth Analg , vol.95 , pp. 1669-1674
    • Chen, X.1    Tang, J.2    White, P.F.3
  • 18
    • 6444233480 scopus 로고    scopus 로고
    • Is the patient state analyzer with the PSArray2 a cost-effective alternative to the bispectral index monitor during the perioperative period?
    • White PF, Tang J, Ma H, Wender RH, Sloninsky A, Kariger R. Is the patient state analyzer with the PSArray2 a cost-effective alternative to the bispectral index monitor during the perioperative period? Anesth Analg. 2004;99:1429-1435.
    • (2004) Anesth Analg , vol.99 , pp. 1429-1435
    • White, P.F.1    Tang, J.2    Ma, H.3    Wender, R.H.4    Sloninsky, A.5    Kariger, R.6
  • 19
    • 0031657514 scopus 로고    scopus 로고
    • A primer for EEG signal processing in anesthesia
    • Rampil IJ. A primer for EEG signal processing in anesthesia. Anesthesiology. 1998;89:980-1002.
    • (1998) Anesthesiology , vol.89 , pp. 980-1002
    • Rampil, I.J.1
  • 20
    • 0242408695 scopus 로고    scopus 로고
    • Deep sedation with propofol by nonanesthesiologists: A prospective pediatric experience
    • Barbi E, Gerarduzzi T, Marchetti F, et al. Deep sedation with propofol by nonanesthesiologists: a prospective pediatric experience. Arch Pediatr Adolesc Med. 2003;157:1097-1103.
    • (2003) Arch Pediatr Adolesc Med , vol.157 , pp. 1097-1103
    • Barbi, E.1    Gerarduzzi, T.2    Marchetti, F.3
  • 21
    • 0037214330 scopus 로고    scopus 로고
    • Safety and efficacy of office-based surgery with monitored anesthesia care/sedation in 4778 consecutive plastic surgery procedures
    • Bitar G, Mullis W, Jacobs W, et al. Safety and efficacy of office-based surgery with monitored anesthesia care/sedation in 4778 consecutive plastic surgery procedures. Plast Reconstr Surg. 2003;111:150-156.
    • (2003) Plast Reconstr Surg , vol.111 , pp. 150-156
    • Bitar, G.1    Mullis, W.2    Jacobs, W.3
  • 22
    • 0032469258 scopus 로고    scopus 로고
    • Electrical cardioversion of atrial fibrillation or flutter with conscious sedation in the age of cost containment
    • Goldner BG, Baker J, Accordino A, et al. Electrical cardioversion of atrial fibrillation or flutter with conscious sedation in the age of cost containment. Am Heart J. 1998;136:961-964.
    • (1998) Am Heart J , vol.136 , pp. 961-964
    • Goldner, B.G.1    Baker, J.2    Accordino, A.3
  • 23
    • 0032165202 scopus 로고    scopus 로고
    • The pediatric sedation unit: A mechanism for pediatric sedation
    • Lowrie L, Weiss AH, Lacombe C. The pediatric sedation unit: a mechanism for pediatric sedation. Pediatrics. 1998;102:E30.
    • (1998) Pediatrics , vol.102
    • Lowrie, L.1    Weiss, A.H.2    Lacombe, C.3
  • 24
    • 0023856373 scopus 로고
    • Unexpected cardiac arrest during spinal anesthesia: A closed claims analysis of predisposing factors
    • Caplan RA, Ward RJ, Posner K, Cheney FW. Unexpected cardiac arrest during spinal anesthesia: a closed claims analysis of predisposing factors. Anesthesiology. 1988;68:5-11.
    • (1988) Anesthesiology , vol.68 , pp. 5-11
    • Caplan, R.A.1    Ward, R.J.2    Posner, K.3    Cheney, F.W.4
  • 26
    • 0037328357 scopus 로고    scopus 로고
    • Can the bispectral index monitor quantify altered level of consciousness in emergency department patients?
    • Gill M, Green SM, Krauss B. Can the bispectral index monitor quantify altered level of consciousness in emergency department patients? Acad Emerg Med. 2003;10:175-179.
    • (2003) Acad Emerg Med , vol.10 , pp. 175-179
    • Gill, M.1    Green, S.M.2    Krauss, B.3
  • 27
    • 0036216815 scopus 로고    scopus 로고
    • Is the bispectral index appropriate for monitoring the sedation level of mechanically ventilated surgical ICU patients?
    • Frenzel D, Greim CA, Sommer C, Bauerle K, Roewer N. Is the bispectral index appropriate for monitoring the sedation level of mechanically ventilated surgical ICU patients? Intensive Care Med. 2002;28:178-183.
    • (2002) Intensive Care Med , vol.28 , pp. 178-183
    • Frenzel, D.1    Greim, C.A.2    Sommer, C.3    Bauerle, K.4    Roewer, N.5
  • 28
    • 0036915141 scopus 로고    scopus 로고
    • Bispectral Indexin ICU: Correlation with Ramsay Score on assessment of sedation level
    • Mondello E, Siliotti R, Note G, et al. Bispectral Indexin ICU: correlation with Ramsay Score on assessment of sedation level. J Clin Monit Comput. 2002;17:271-277.
    • (2002) J Clin Monit Comput , vol.17 , pp. 271-277
    • Mondello, E.1    Siliotti, R.2    Note, G.3
  • 29
    • 0037373530 scopus 로고    scopus 로고
    • Correlation of approximate entropy, bispectral index, and spectral edge frequency 95 (SEF95) with clinical signs of "anesthetic depth" during coadministration of propofol and remifentanil
    • Bruhn J, Bouillon TW, Radulescu L, Hoeft A, Bertaccini E, Shafer SL. Correlation of approximate entropy, bispectral index, and spectral edge frequency 95 (SEF95) with clinical signs of "anesthetic depth" during coadministration of propofol and remifentanil. Anesthesiology. 2003;98:621-627.
    • (2003) Anesthesiology , vol.98 , pp. 621-627
    • Bruhn, J.1    Bouillon, T.W.2    Radulescu, L.3    Hoeft, A.4    Bertaccini, E.5    Shafer, S.L.6
  • 31
    • 0041334011 scopus 로고    scopus 로고
    • Randomized clinical trial of propofol versus methohexital for procedural sedation during fracture and dislocation reduction in the emergency department
    • Miner JR, Biros M, Krieg S, Johnson C, Heegaard W, Plummer D. Randomized clinical trial of propofol versus methohexital for procedural sedation during fracture and dislocation reduction in the emergency department. Acad Emerg Med. 2003;10:931-937.
    • (2003) Acad Emerg Med , vol.10 , pp. 931-937
    • Miner, J.R.1    Biros, M.2    Krieg, S.3    Johnson, C.4    Heegaard, W.5    Plummer, D.6
  • 32
    • 0038616399 scopus 로고    scopus 로고
    • Bispectral electroencephalographic analysis of patients undergoing procedural sedation in the emergency department
    • Miner JR, Biros MH, Heegaard W, Plummer D. Bispectral electroencephalographic analysis of patients undergoing procedural sedation in the emergency department. Acad Emerg Med. 2003;10:638-643.
    • (2003) Acad Emerg Med , vol.10 , pp. 638-643
    • Miner, J.R.1    Biros, M.H.2    Heegaard, W.3    Plummer, D.4
  • 33
    • 0141432147 scopus 로고    scopus 로고
    • Ability of the bispectral index, autoregressive modelling with exogenous input-derived auditory evoked potentials, and predicted propofol concentrations to measure patient responsiveness during anesthesia with propofol and remifentanil
    • Struys MM, Vereecke H, Moerman A, et al. Ability of the bispectral index, autoregressive modelling with exogenous input-derived auditory evoked potentials, and predicted propofol concentrations to measure patient responsiveness during anesthesia with propofol and remifentanil. Anesthesiology. 2003;99:802-812.
    • (2003) Anesthesiology , vol.99 , pp. 802-812
    • Struys, M.M.1    Vereecke, H.2    Moerman, A.3
  • 34
    • 0344653602 scopus 로고    scopus 로고
    • Bispectral analysis of the electroencephalogram predicts conscious processing of information during propofol sedation and hypnosis
    • Kearse LA Jr, Rosow C, Zaslavsky A, Connors P, Dershwitz M, Denman W. Bispectral analysis of the electroencephalogram predicts conscious processing of information during propofol sedation and hypnosis. Anesthesiology. 1998;88:25-34.
    • (1998) Anesthesiology , vol.88 , pp. 25-34
    • Kearse Jr., L.A.1    Rosow, C.2    Zaslavsky, A.3    Connors, P.4    Dershwitz, M.5    Denman, W.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.