-
1
-
-
0042883743
-
Testing force systems and biomechanics-measured tooth movements from differential moment closing loops
-
Kuhlberg A.J., and Priebe D.N. Testing force systems and biomechanics-measured tooth movements from differential moment closing loops. Angle Orthod 73 (2003) 270-280
-
(2003)
Angle Orthod
, vol.73
, pp. 270-280
-
-
Kuhlberg, A.J.1
Priebe, D.N.2
-
3
-
-
0031253291
-
Efficacy of intra-arch mechanics using differential moments for achieving anchorage control in extraction cases
-
Rajcich M.M., and Sadowsky C. Efficacy of intra-arch mechanics using differential moments for achieving anchorage control in extraction cases. Am J Orthod Dentofacial Orthop 112 (1997) 441-448
-
(1997)
Am J Orthod Dentofacial Orthop
, vol.112
, pp. 441-448
-
-
Rajcich, M.M.1
Sadowsky, C.2
-
4
-
-
0036715840
-
The role of implants in orthodontics
-
Ismail S.F.H., and Johal A.S. The role of implants in orthodontics. J Orthod 29 (2002) 239-245
-
(2002)
J Orthod
, vol.29
, pp. 239-245
-
-
Ismail, S.F.H.1
Johal, A.S.2
-
5
-
-
7044264818
-
Sliding mechanics with microscrew implant anchorage
-
Park H.S., and Kwon T.G. Sliding mechanics with microscrew implant anchorage. Angle Orthod 74 (2004) 703-710
-
(2004)
Angle Orthod
, vol.74
, pp. 703-710
-
-
Park, H.S.1
Kwon, T.G.2
-
6
-
-
12444293764
-
Radiographic evaluation of the availability of bone for placement of miniscrews
-
Schnelle M.A., Beck F.M., Jaynes R.M., and Huja S.S. Radiographic evaluation of the availability of bone for placement of miniscrews. Angle Orthod 74 (2004) 832-837
-
(2004)
Angle Orthod
, vol.74
, pp. 832-837
-
-
Schnelle, M.A.1
Beck, F.M.2
Jaynes, R.M.3
Huja, S.S.4
-
7
-
-
0021472181
-
Osseous adaptation to continuous loading of rigid endosseous implants
-
Roberts W.E. Osseous adaptation to continuous loading of rigid endosseous implants. Am J Orthod 86 (1984) 95-111
-
(1984)
Am J Orthod
, vol.86
, pp. 95-111
-
-
Roberts, W.E.1
-
8
-
-
0242273196
-
Bodily distalization of molars with absolute anchorage
-
Keles A., Erverdi N., and Sezen S. Bodily distalization of molars with absolute anchorage. Angle Orthod 73 (2003) 471-482
-
(2003)
Angle Orthod
, vol.73
, pp. 471-482
-
-
Keles, A.1
Erverdi, N.2
Sezen, S.3
-
9
-
-
2342637111
-
Orthodontic palatal implants: clinical technique
-
Tinsley D., O'Dwyer J.J., Benson P.E., Doyle P.T., and Sander J. Orthodontic palatal implants: clinical technique. J Orthod 31 (2004) 3-8
-
(2004)
J Orthod
, vol.31
, pp. 3-8
-
-
Tinsley, D.1
O'Dwyer, J.J.2
Benson, P.E.3
Doyle, P.T.4
Sander, J.5
-
10
-
-
18244396093
-
Use of onplants as stable anchorage for facemask treatment: a case report
-
Hong H., Ngan P., Li G.H., Qi L.G., and Wei S.H.Y. Use of onplants as stable anchorage for facemask treatment: a case report. Angle Orthod 75 (2005) 453-460
-
(2005)
Angle Orthod
, vol.75
, pp. 453-460
-
-
Hong, H.1
Ngan, P.2
Li, G.H.3
Qi, L.G.4
Wei, S.H.Y.5
-
11
-
-
13844272679
-
Comparison of maxillary canine retraction with sliding mechanics and a retraction spring: a three-dimensional analysis based on a midpalatal orthodontic implant
-
Hayashi K., Uechi J., Murata M., and Mizoguchi I. Comparison of maxillary canine retraction with sliding mechanics and a retraction spring: a three-dimensional analysis based on a midpalatal orthodontic implant. Eur J Orthod 26 (2004) 585-589
-
(2004)
Eur J Orthod
, vol.26
, pp. 585-589
-
-
Hayashi, K.1
Uechi, J.2
Murata, M.3
Mizoguchi, I.4
-
12
-
-
18244396344
-
Zygomatic anchorage for en masse retraction in the treatment of severe Class II Division 1
-
Erverdi N., and Acar A. Zygomatic anchorage for en masse retraction in the treatment of severe Class II Division 1. Angle Orthod 75 (2005) 483-490
-
(2005)
Angle Orthod
, vol.75
, pp. 483-490
-
-
Erverdi, N.1
Acar, A.2
-
13
-
-
0033073848
-
Skeletal anchorage system for open-bite correction
-
Unemori M., Sugawara J., Mitani H., Nagasaki H., and Kawamura H. Skeletal anchorage system for open-bite correction. Am J Orthod Dentofacial Orthop 115 (1999) 166-174
-
(1999)
Am J Orthod Dentofacial Orthop
, vol.115
, pp. 166-174
-
-
Unemori, M.1
Sugawara, J.2
Mitani, H.3
Nagasaki, H.4
Kawamura, H.5
-
14
-
-
14544303622
-
Miniscrew implants: IMTEC mini ortho implants
-
Herman R., and Cope J.B. Miniscrew implants: IMTEC mini ortho implants. Semin Orthod 11 (2005) 32-39
-
(2005)
Semin Orthod
, vol.11
, pp. 32-39
-
-
Herman, R.1
Cope, J.B.2
-
15
-
-
14544272341
-
Miniscrew implants: the spider screw anchorage system
-
Maino B.G., Mura P., and Bednar J. Miniscrew implants: the spider screw anchorage system. Semin Orthod 11 (2005) 40-46
-
(2005)
Semin Orthod
, vol.11
, pp. 40-46
-
-
Maino, B.G.1
Mura, P.2
Bednar, J.3
-
17
-
-
33646557306
-
Implantable devices as orthodontic anchorage: a review of current treatment modalities
-
Heymann G.C., and Tulloch J.F. Implantable devices as orthodontic anchorage: a review of current treatment modalities. J Esthet Restor Dent 18 (2006) 68-79
-
(2006)
J Esthet Restor Dent
, vol.18
, pp. 68-79
-
-
Heymann, G.C.1
Tulloch, J.F.2
-
18
-
-
33745835122
-
Factors affecting the clinical success of screw implants used as orthodontic anchorage
-
Park H.S., Jeong S.H., and Kwon O.W. Factors affecting the clinical success of screw implants used as orthodontic anchorage. Am J Orthod Dentofacial Orthop 130 (2006) 18-25
-
(2006)
Am J Orthod Dentofacial Orthop
, vol.130
, pp. 18-25
-
-
Park, H.S.1
Jeong, S.H.2
Kwon, O.W.3
-
19
-
-
21644433269
-
Group distal movement of teeth using microscrew implant anchorage
-
Park H.S., Lee S.K., and Kwon O.W. Group distal movement of teeth using microscrew implant anchorage. Angle Orthod 75 (2005) 602-609
-
(2005)
Angle Orthod
, vol.75
, pp. 602-609
-
-
Park, H.S.1
Lee, S.K.2
Kwon, O.W.3
-
20
-
-
4444249537
-
Nonextraction treatment with microscrew implants
-
Park H.S., Kwon T.G., and Sung J.H. Nonextraction treatment with microscrew implants. Angle Orthod 74 (2004) 539-549
-
(2004)
Angle Orthod
, vol.74
, pp. 539-549
-
-
Park, H.S.1
Kwon, T.G.2
Sung, J.H.3
-
21
-
-
18244387213
-
A mini-implant for orthodontic anchorage in a deep overbite case
-
Ohnishi H., Yagi T., Yasuda Y., and Takada K. A mini-implant for orthodontic anchorage in a deep overbite case. Angle Orthod 75 (2005) 444-452
-
(2005)
Angle Orthod
, vol.75
, pp. 444-452
-
-
Ohnishi, H.1
Yagi, T.2
Yasuda, Y.3
Takada, K.4
-
22
-
-
0141921987
-
Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage
-
Miyawaki S., Koyama I., Inoue M., Mishima K., Sugarara T., and Takano-Yamamoto T. Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. Am J Orthod Dentofacial Orthop 124 (2003) 373-378
-
(2003)
Am J Orthod Dentofacial Orthop
, vol.124
, pp. 373-378
-
-
Miyawaki, S.1
Koyama, I.2
Inoue, M.3
Mishima, K.4
Sugarara, T.5
Takano-Yamamoto, T.6
-
23
-
-
14544287285
-
Miniscrew implants: the Aarhus anchorage system
-
Melsen B., and Verna C. Miniscrew implants: the Aarhus anchorage system. Semin Orthod 11 (2005) 24-31
-
(2005)
Semin Orthod
, vol.11
, pp. 24-31
-
-
Melsen, B.1
Verna, C.2
-
24
-
-
33845863912
-
Clinical use of miniscrew implants as orthodontic anchorage: success rate and postoperative discomfort
-
Kuroda S., Sugawara Y., Deguchi T., Kyung H.M., and Yamamoto T.T. Clinical use of miniscrew implants as orthodontic anchorage: success rate and postoperative discomfort. Am J Orthod Dentofacial Orthop 131 (2007) 9-15
-
(2007)
Am J Orthod Dentofacial Orthop
, vol.131
, pp. 9-15
-
-
Kuroda, S.1
Sugawara, Y.2
Deguchi, T.3
Kyung, H.M.4
Yamamoto, T.T.5
-
27
-
-
16644381734
-
Clinical applications of the miniscrew anchorage system (M.A.S) in the maxillary alveolar bone
-
Carano A., Velo S., Incorvati C., and Poggio P. Clinical applications of the miniscrew anchorage system (M.A.S) in the maxillary alveolar bone. Prog Orthod 5 (2004) 212-235
-
(2004)
Prog Orthod
, vol.5
, pp. 212-235
-
-
Carano, A.1
Velo, S.2
Incorvati, C.3
Poggio, P.4
-
28
-
-
33644639434
-
"Safe zones": a guide for miniscrew positioning in the maxillary and mandibular arch
-
Poggio P., Incorvati C., Velo S., and Carano A. "Safe zones": a guide for miniscrew positioning in the maxillary and mandibular arch. Angle Orthod 76 (2006) 191-197
-
(2006)
Angle Orthod
, vol.76
, pp. 191-197
-
-
Poggio, P.1
Incorvati, C.2
Velo, S.3
Carano, A.4
-
29
-
-
1342322625
-
A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage
-
Cheng S.J., Tseng I.Y., Lee J.J., and Kok S.H. A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage. Int J Oral Maxillofac Implants 19 (2004) 100-106
-
(2004)
Int J Oral Maxillofac Implants
, vol.19
, pp. 100-106
-
-
Cheng, S.J.1
Tseng, I.Y.2
Lee, J.J.3
Kok, S.H.4
-
30
-
-
34247158149
-
Root proximity is a major factor for screw failure in orthodontic anchorage
-
Kuroda S., Yamada K., Deguchi T., Hashimoto T., Kyung H.M., and Yamamoto T.T. Root proximity is a major factor for screw failure in orthodontic anchorage. Am J Orthod Dentofacial Orthop 131 Suppl (2007) S68-S73
-
(2007)
Am J Orthod Dentofacial Orthop
, vol.131
, Issue.SUPPL
-
-
Kuroda, S.1
Yamada, K.2
Deguchi, T.3
Hashimoto, T.4
Kyung, H.M.5
Yamamoto, T.T.6
-
31
-
-
34247167529
-
Risks and complications of orthodontic miniscrews
-
Kravitz N.D., and Kusnoto B. Risks and complications of orthodontic miniscrews. Am J Orthod Dentofacial Orthop 131 Suppl (2007) S43-S51
-
(2007)
Am J Orthod Dentofacial Orthop
, vol.131
, Issue.SUPPL
-
-
Kravitz, N.D.1
Kusnoto, B.2
-
32
-
-
0031690012
-
Vertebral bone density evaluated by dual-energy x-ray absorptiometry and quantitative computed tomography in vitro
-
Ebbesen E.N., Thomsen J.S., Beck-Nielsen J., Nepper-Rasmussen H.J., and Mosekilde L.I. Vertebral bone density evaluated by dual-energy x-ray absorptiometry and quantitative computed tomography in vitro. Bone 23 (1998) 283-290
-
(1998)
Bone
, vol.23
, pp. 283-290
-
-
Ebbesen, E.N.1
Thomsen, J.S.2
Beck-Nielsen, J.3
Nepper-Rasmussen, H.J.4
Mosekilde, L.I.5
-
33
-
-
0037120864
-
Clinical use of bone densitometry: scientific review
-
Cummings S.R., Bates D., and Black D.M. Clinical use of bone densitometry: scientific review. JAMA 288 (2002) 1889-1897
-
(2002)
JAMA
, vol.288
, pp. 1889-1897
-
-
Cummings, S.R.1
Bates, D.2
Black, D.M.3
-
34
-
-
0025583331
-
Divisions of available bone in implant dentistry
-
Misch C.E. Divisions of available bone in implant dentistry. Int J Oral Implants 7 (1990) 9-17
-
(1990)
Int J Oral Implants
, vol.7
, pp. 9-17
-
-
Misch, C.E.1
-
35
-
-
0027793713
-
On long-term maintenance of the osseointegrated response
-
Albrektsson T. On long-term maintenance of the osseointegrated response. Aust Prosthodont J 7 (1999) 15-24
-
(1999)
Aust Prosthodont J
, vol.7
, pp. 15-24
-
-
Albrektsson, T.1
-
36
-
-
0036546264
-
Computed tomography evaluation of temporomandibular joint alterations in Class II Division 1 subdivision patients: condylar symmetry
-
Vitral R.W.F., and Telles C.S. Computed tomography evaluation of temporomandibular joint alterations in Class II Division 1 subdivision patients: condylar symmetry. Am J Orthod Dentofacial Orthop 121 (2002) 369-375
-
(2002)
Am J Orthod Dentofacial Orthop
, vol.121
, pp. 369-375
-
-
Vitral, R.W.F.1
Telles, C.S.2
-
37
-
-
0742284062
-
Bone mineral density measurement techniques
-
Ibáñez R. Bone mineral density measurement techniques. An Sist Sanit Navar 26 Suppl 3 (2003) 19-27
-
(2003)
An Sist Sanit Navar
, vol.26
, Issue.SUPPL. 3
, pp. 19-27
-
-
Ibáñez, R.1
-
38
-
-
0035261160
-
Bone classification: an objective scale of bone density using the computerized tomography scan
-
Norton M.R., and Gamble C. Bone classification: an objective scale of bone density using the computerized tomography scan. Clin Oral Implants Res 12 (2001) 79-84
-
(2001)
Clin Oral Implants Res
, vol.12
, pp. 79-84
-
-
Norton, M.R.1
Gamble, C.2
-
39
-
-
0002172340
-
Patient selection and preparation
-
Branemark P.I., Zarb G.A., and Alberktsson T. (Eds), Quintessence, Chicago
-
Lekholm U., and Zahr G.A. Patient selection and preparation. In: Branemark P.I., Zarb G.A., and Alberktsson T. (Eds). Osseointegration in clinical dentstry (1985), Quintessence, Chicago 199-209
-
(1985)
Osseointegration in clinical dentstry
, pp. 199-209
-
-
Lekholm, U.1
Zahr, G.A.2
-
40
-
-
0037735330
-
Bone density assessment of dental implant sites: 1. Quantitative computed tomography
-
Shahlaie M., Gantes B., Schulz E., Riggs M., and Crigger M. Bone density assessment of dental implant sites: 1. Quantitative computed tomography. Int J Oral Maxillofac Implants 18 (2003) 224-231
-
(2003)
Int J Oral Maxillofac Implants
, vol.18
, pp. 224-231
-
-
Shahlaie, M.1
Gantes, B.2
Schulz, E.3
Riggs, M.4
Crigger, M.5
-
41
-
-
17844379203
-
Assessment of correlation between computerized tomography values of the bone and cutting torque values at implant placement: a clinical study
-
Ikumi N., and Tsutsumi S. Assessment of correlation between computerized tomography values of the bone and cutting torque values at implant placement: a clinical study. Int J Oral Maxillofac Implants 20 (2005) 253-260
-
(2005)
Int J Oral Maxillofac Implants
, vol.20
, pp. 253-260
-
-
Ikumi, N.1
Tsutsumi, S.2
-
42
-
-
0344010698
-
Correlation of insertion torques with bone mineral density from dental quantitative CT in the mandible
-
Beer A., Gahleitner A., Holm A., Tschabitscher M., and Homolka P. Correlation of insertion torques with bone mineral density from dental quantitative CT in the mandible. Clin Oral Implants Res 14 (2003) 616-620
-
(2003)
Clin Oral Implants Res
, vol.14
, pp. 616-620
-
-
Beer, A.1
Gahleitner, A.2
Holm, A.3
Tschabitscher, M.4
Homolka, P.5
-
43
-
-
67949099962
-
-
Available at:, Accessed on June 27, 2007
-
Straumann Ortho Implant. Indication for use. Available at: http://www.fda.gov/cdrh/pdf4/k040469.pdf. Accessed on June 27, 2007.
-
Straumann Ortho Implant. Indication for use
-
-
-
44
-
-
0034778193
-
Vitamin D deficiency and bone health in healthy adults in Finland: could this be a concern in other parts of Europe?
-
Lamberg-Allardt C.J., Outila T.A., Karkkainen M.U., Rita H.J., and Valsta L.M. Vitamin D deficiency and bone health in healthy adults in Finland: could this be a concern in other parts of Europe?. J Bone Miner Res 16 (2001) 2066-2073
-
(2001)
J Bone Miner Res
, vol.16
, pp. 2066-2073
-
-
Lamberg-Allardt, C.J.1
Outila, T.A.2
Karkkainen, M.U.3
Rita, H.J.4
Valsta, L.M.5
-
46
-
-
14544296122
-
Intraoral hard and soft depths for temporary anchorage devices
-
Costa A., Pasta G., and Bergamaschi G. Intraoral hard and soft depths for temporary anchorage devices. Semin Orthod 11 (2005) 10-15
-
(2005)
Semin Orthod
, vol.11
, pp. 10-15
-
-
Costa, A.1
Pasta, G.2
Bergamaschi, G.3
|