메뉴 건너뛰기




Volumn 86, Issue 5, 2009, Pages 454-466

Modeling corneal metabolism and oxygen transport during contact lens wear

Author keywords

Contact lens; Cornea; Metabolism; Oxygen consumption; Oxygen flux

Indexed keywords

ANTERIOR CHAMBER; CONTACT LENS WEAR; CONTINUUM REACTION; CORNEA; EXTENDED WEARS; EYE CONTACT; GLUCOSE METABOLISM; HYDROGEN IONS; ION TRANSPORTS; LACTATE CONCENTRATION; LENS SYSTEMS; METABOLIC MODELS; METABOLIC REACTIONS; METABOLIC SHIFT; MONOD KINETIC; NEW INDICES; OXYGEN CONSUMPTION; OXYGEN DEFICIENCY; OXYGEN DEPLETION; OXYGEN DEPRIVATION; OXYGEN DIFFUSION; OXYGEN FLUX; OXYGEN TRANSPORT; REACTIVE LOSS; REACTIVE SPECIES; SPECIES CONCENTRATION; TEAR FILMS; TRICARBOXYLIC ACID CYCLE;

EID: 67651148249     PISSN: 10405488     EISSN: None     Source Type: Journal    
DOI: 10.1097/OPX.0b013e31819f9e70     Document Type: Article
Times cited : (39)

References (71)
  • 1
    • 0015382535 scopus 로고
    • Oxygen consumption by the component layers of the cornea
    • Lond
    • Freeman RD. Oxygen consumption by the component layers of the cornea. J Physiol (Lond) 1972;225:15-32.
    • (1972) J Physiol , vol.225 , pp. 15-32
    • Freeman, R.D.1
  • 3
    • 0014440587 scopus 로고
    • Steady state distribution of oxygen and carbon dioxide in the in vivo cornea of an eye covered by a gas-permeable contact lens
    • Fatt I, Bieber MT, Pye SD. Steady state distribution of oxygen and carbon dioxide in the in vivo cornea of an eye covered by a gas-permeable contact lens. Am J Optom Arch Am Acad Optom 1969;46:3-14.
    • (1969) Am J Optom Arch Am Acad Optom , vol.46 , pp. 3-14
    • Fatt, I.1    Bieber, M.T.2    Pye, S.D.3
  • 4
    • 0025039785 scopus 로고
    • Corneal pathophysiology with contact lens wear
    • DOI 10.1016/0039-6257(90)90046-X
    • Bruce AS, Brennan NA. Corneal pathophysiology with contact lens wear. Surv Ophthalmol 1990;35:25-58. (Pubitemid 20246193)
    • (1990) Survey of Ophthalmology , vol.35 , Issue.1 , pp. 25-58
    • Bruce, A.S.1    Brennan, N.A.2
  • 6
    • 0037664653 scopus 로고    scopus 로고
    • Clinical signs of hypoxia with high-Dk soft lens extended wear: Is the cornea convinced?
    • Sweeney DF. Clinical signs of hypoxia with high-Dk soft lens extended wear: is the cornea convinced? Eye Contact Lens 2003;29:S22-5.
    • (2003) Eye Contact Lens , vol.29
    • Sweeney, D.F.1
  • 9
    • 0023155380 scopus 로고
    • Measurement of in vivo human corneal stromal pH: Open and closed eyes
    • Bonanno JA, Polse KA. Measurement of in vivo human corneal stromal pH: open and closed eyes. Invest Ophthalmol Vis Sci 1987;28: 522-530
    • (1987) Invest Ophthalmol Vis Sci , vol.28 , pp. 522-530
    • Bonanno, J.A.1    Polse, K.A.2
  • 10
    • 0019731768 scopus 로고
    • Stromal lactate accumulation can account for corneal oedema osmotically following epithelial hypoxia in the rabbit
    • Lond
    • Klyce SD. Stromal lactate accumulation can account for corneal oedema osmotically following epithelial hypoxia in the rabbit. J Physiol (Lond) 1981;321:49-64.
    • (1981) J Physiol , vol.321 , pp. 49-64
    • Klyce, S.D.1
  • 12
    • 0014242008 scopus 로고
    • The steady-state distribution of oxygen and carbon dioxide in the in vivo cornea. I. The open eye in air and the closed eye
    • Fatt I, Bieber MT. The steady-state distribution of oxygen and carbon dioxide in the in vivo cornea. I. The open eye in air and the closed eye. Exp Eye Res 1968;7:103-112
    • (1968) Exp Eye Res , vol.7 , pp. 103-112
    • Fatt, I.1    Bieber, M.T.2
  • 13
    • 0014304897 scopus 로고
    • Steady-state distribution of oxygen and carbon dioxide in the in vivo cornea. II. The open eye in nitrogen and the covered eye
    • Fatt I. Steady-state distribution of oxygen and carbon dioxide in the in vivo cornea. II. The open eye in nitrogen and the covered eye. Exp Eye Res 1968;7:413-430
    • (1968) Exp Eye Res , vol.7 , pp. 413-430
    • Fatt, I.1
  • 14
    • 0016190287 scopus 로고
    • Oxygen tension distributions in the cornea: A re-examination
    • Fatt I, Freeman RD, Lin D. Oxygen tension distributions in the cornea: a re-examination. Exp Eye Res 1974;18:357-365
    • (1974) Exp Eye Res , vol.18 , pp. 357-365
    • Fatt, I.1    Freeman, R.D.2    Lin, D.3
  • 15
    • 0022081635 scopus 로고
    • Spatial distribution of oxygen in the cornea of a closed eye wearing a gas permeable contact lens
    • Fatt I, Lin D. Spatial distribution of oxygen in the cornea of a closed eye wearing a gas permeable contact lens. Curr Eye Res 1985;4: 723-724
    • (1985) Curr Eye Res , vol.4 , pp. 723-724
    • Fatt, I.1    Lin, D.2
  • 16
    • 0032843148 scopus 로고    scopus 로고
    • Re-evaluation of the oxygen diffusion model for predicting minimum contact lens Dk/t values needed to avoid corneal anoxia
    • Harvitt DM, Bonanno JA. Re-evaluation of the oxygen diffusion model for predicting minimum contact lens Dk/t values needed to avoid corneal anoxia. Optom Vis Sci 1999;76:712-719
    • (1999) Optom Vis Sci , vol.76 , pp. 712-719
    • Harvitt, D.M.1    Bonanno, J.A.2
  • 17
    • 18344393472 scopus 로고    scopus 로고
    • Corneal oxygenation during contact lens wear: Comparison of diffusion and EOP-based flux models
    • Brennan NA. Corneal oxygenation during contact lens wear: comparison of diffusion and EOP-based flux models. Clin Exp Optom 2005;88:103-108
    • (2005) Clin Exp Optom , vol.88 , pp. 103-108
    • Brennan, N.A.1
  • 18
    • 21344464651 scopus 로고    scopus 로고
    • Beyond flux: Total corneal oxygen consumption as an index of corneal oxygenation during contact lens wear
    • Brennan NA. Beyond flux: total corneal oxygen consumption as an index of corneal oxygenation during contact lens wear. Optom Vis Sci 2005;82:467-472
    • (2005) Optom Vis Sci , vol.82 , pp. 467-472
    • Brennan, N.A.1
  • 19
    • 34447559953 scopus 로고    scopus 로고
    • Corneal oxygen distribution with contact lens wear
    • DOI 10.1097/ICO.0b013e31804f5a22, PII 0000322620070700000003
    • Alvord LA, Hall WJ, Keyes LD, Morgan CF, Winterton LC. Corneal oxygen distribution with contact lens wear. Cornea 2007;26:654-664 (Pubitemid 47080281)
    • (2007) Cornea , vol.26 , Issue.6 , pp. 654-664
    • Alvord, L.A.1    Hall, W.J.2    Keyes, L.D.3    Morgan, C.F.4    Winterton, L.C.5
  • 20
    • 0030067863 scopus 로고    scopus 로고
    • New physiological paradigms to assess the effect of lens oxygen transmissibility on corneal health
    • Fatt I. New physiological paradigms to assess the effect of lens oxygen transmissibility on corneal health. CLAO J 1996;22:25-29 (Pubitemid 26039083)
    • (1996) CLAO Journal , vol.22 , Issue.1 , pp. 25-29
    • Fatt, I.1
  • 21
    • 0015094201 scopus 로고
    • Oxygen tension under an oxygen-permeable contact lens
    • Fatt I, St Helen R. Oxygen tension under an oxygen-permeable contact lens. Am J Optom Arch Am Acad Optom 1971;48:545-555
    • (1971) Am J Optom Arch Am Acad Optom , vol.48 , pp. 545-555
    • Fatt, I.1    St Helen, R.2
  • 22
    • 38249004254 scopus 로고
    • A new oxygen transmissibility concept for hydrogel contact lenses
    • Fatt I, Ruben CM. A new oxygen transmissibility concept for hydrogel contact lenses. J Br Contact Lens Assoc 1993;16:141-149
    • (1993) J Br Contact Lens Assoc , vol.16 , pp. 141-149
    • Fatt, I.1    Ruben, C.M.2
  • 23
    • 73849159212 scopus 로고
    • Some aspects of the carbohydrate metabolism of the cornea
    • Kinoshita JH. Some aspects of the carbohydrate metabolism of the cornea. Invest Ophthalmol 1962;1:178-186
    • (1962) Invest Ophthalmol , vol.1 , pp. 178-186
    • Kinoshita, J.H.1
  • 24
    • 17744411045 scopus 로고
    • Role of glucose in corneal metabolism
    • Thies RS, Mandel LJ. Role of glucose in corneal metabolism. Am J Physiol 1985;249:C409-16.
    • (1985) Am J Physiol , vol.249
    • Thies, R.S.1    Mandel, L.J.2
  • 26
    • 0033983891 scopus 로고    scopus 로고
    • Effects of RGP lens extended wear on glucose-lactate metabolism and stromal swelling in the rabbit cornea
    • Ichijima H, Imayasu M, Tanaka H, Ren DH, Cavanagh HD. Effects of RGP lens extended wear on glucose-lactate metabolism and stromal swelling in the rabbit cornea. CLAO J 2000;26:30-36 (Pubitemid 30053812)
    • (2000) CLAO Journal , vol.26 , Issue.1 , pp. 30-36
    • Ichijima, H.1    Imayasu, M.2    Tanaka, H.3    Ren, D.H.4    Cavanagh, H.D.5
  • 27
    • 0014502521 scopus 로고
    • Glucose and oxygen utilization by the rabbit cornea
    • Riley MV. Glucose and oxygen utilization by the rabbit cornea. Exp Eye Res 1969;8:193-200.
    • (1969) Exp Eye Res , vol.8 , pp. 193-200
    • Riley, M.V.1
  • 29
    • 0001117633 scopus 로고
    • The ionization of lactic acid from zero to fifty degrees
    • Available at: Accessed January 16, 2009
    • Nims LF, Smith PK. The ionization of lactic acid from zero to fifty degrees. J Biol Chem 1936;113:145-52. Available at: http:// www.jbc.org/cgi/ reprint/113/1/145.pdf. Accessed January 16, 2009.
    • (1936) J Biol Chem , vol.113 , pp. 145-152
    • Nims, L.F.1    Smith, P.K.2
  • 30
    • 0033930496 scopus 로고    scopus 로고
    • The effects of one-hour wear of high-Dk soft contact lenses on corneal pH and epithelial permeability
    • Lin MC, Graham AD, Polse KA, McNamara NA, Tieu TG. The effects of one-hour wear of high-Dk soft contact lenses on corneal pH and epithelial permeability. CLAO J 2000;26:130-133
    • (2000) CLAO J , vol.26 , pp. 130-133
    • Lin, M.C.1    Graham, A.D.2    Polse, K.A.3    McNamara, N.A.4    Tieu, T.G.5
  • 31
    • 0003081944 scopus 로고
    • The cornea
    • Graymore CN, ed. London: Academic Press
    • Maurice DM, Riley MV. The cornea. In: Graymore CN, ed. Biochemistry of the Eye. London: Academic Press, 1970:1-130.
    • (1970) Biochemistry of the Eye , pp. 1-130
    • Maurice, D.M.1    Riley, M.V.2
  • 33
    • 0026476498 scopus 로고
    • The microchemical detection of carbonic anhydrase in corneal epithelia
    • Conroy CW, Buck RH, Maren TH. The microchemical detection of carbonic anhydrase in corneal epithelia. Exp Eye Res 1992;55: 637-640
    • (1992) Exp Eye Res , vol.55 , pp. 637-640
    • Conroy, C.W.1    Buck, R.H.2    Maren, T.H.3
  • 35
    • 0035159141 scopus 로고    scopus 로고
    • A model of oxygen flux through contact lenses
    • Brennan NA. A model of oxygen flux through contact lenses. Cornea 2001;20:104-108
    • (2001) Cornea , vol.20 , pp. 104-108
    • Brennan, N.A.1
  • 36
    • 0018378705 scopus 로고
    • Tear flow under hydrogel contact lenses
    • Polse KA. Tear flow under hydrogel contact lenses. Invest Ophthalmol Vis Sci 1979;18:409-413
    • (1979) Invest Ophthalmol Vis Sci , vol.18 , pp. 409-413
    • Polse, K.A.1
  • 38
    • 38549163456 scopus 로고    scopus 로고
    • Minimum contact lens oxygen transmissibility (Dk/L) with monod kinetics for the corneal oxygen consumption rate
    • E-Abstract 904
    • Radke CJ, Chhabra M. Minimum contact lens oxygen transmissibility (Dk/L) with monod kinetics for the corneal oxygen consumption rate. Invest Ophthalmol Vis Sci 2005;46:E-Abstract 904.
    • (2005) Invest Ophthalmol Vis Sci , vol.46
    • Radke, C.J.1    Chhabra, M.2
  • 39
    • 67650975333 scopus 로고
    • The respiration of luminous bacteria and the effect of oxygen tension upon oxygen consumption
    • Shoup CS. The respiration of luminous bacteria and the effect of oxygen tension upon oxygen consumption. J Gen Physiol 1929;13:27-45.
    • (1929) J Gen Physiol , vol.13 , pp. 27-45
    • Shoup, C.S.1
  • 40
    • 3142545224 scopus 로고
    • The influence of oxygen tension upon the respiration of unicellular organisms
    • Amberson WR. The influence of oxygen tension upon the respiration of unicellular organisms. Biol Bull 1928;55:79-91.
    • (1928) Biol Bull , vol.55 , pp. 79-91
    • Amberson, W.R.1
  • 41
    • 67650962806 scopus 로고
    • The oxygen tension-oxygen consumption curve of unfertilized arbacia eggs
    • Tang PS. The oxygen tension-oxygen consumption curve of unfertilized arbacia eggs. Biol Bull 1931;60:242-244
    • (1931) Biol Bull , vol.60 , pp. 242-244
    • Tang, P.S.1
  • 42
    • 0013975091 scopus 로고
    • Oxygen consumption rate of tissue measured by a micropolarographic method
    • Takahashi GH, Fatt I, Goldstick TK. Oxygen consumption rate of tissue measured by a micropolarographic method. J Gen Physiol 1966;50:317-335
    • (1966) J Gen Physiol , vol.50 , pp. 317-335
    • Takahashi, G.H.1    Fatt, I.2    Goldstick, T.K.3
  • 44
    • 0344736650 scopus 로고    scopus 로고
    • Improvement of a mammalian cell culture process by adaptive, model-based dialysis fed-batch cultivation and suppression of apoptosis
    • DOI 10.1007/s00449-003-0335-z
    • Frahm B, Lane P, Markl H, Portner R. Improvement of a mammalian cell culture process by adaptive, model-based dialysis fed-batch cultivation and suppression of apoptosis. Bioprocess Biosyst Eng 2003; 26:1-10. (Pubitemid 37494491)
    • (2003) Bioprocess and Biosystems Engineering , vol.26 , Issue.1 , pp. 1-10
    • Frahm, B.1    Lane, P.2    Markl, H.3    Portner, R.4
  • 45
    • 0023281003 scopus 로고
    • Effect of rigid contact lens oxygen transmissibility on stromal pH in the living human eye
    • Bonanno JA, Polse KA. Effect of rigid contact lens oxygen transmissibility on stromal pH in the living human eye. Ophthalmology 1987;94:1305-1309
    • (1987) Ophthalmology , vol.94 , pp. 1305-1309
    • Bonanno, J.A.1    Polse, K.A.2
  • 46
    • 0028213974 scopus 로고
    • Corneal epithelial and aqueous humor acidification during in vivo contact lens wear in rabbits
    • Giasson C, Bonanno JA. Corneal epithelial and aqueous humor acidification during in vivo contact lens wear in rabbits. Invest Ophthalmol Vis Sci 1994;35:851-861 (Pubitemid 24079815)
    • (1994) Investigative Ophthalmology and Visual Science , vol.35 , Issue.3 , pp. 851-861
    • Giasson, C.1    Bonanno, J.A.2
  • 47
    • 0028929102 scopus 로고
    • Acidification of rabbit corneal endothelium during contact lens wear in vitro
    • Giasson C, Bonanno JA. Acidification of rabbit corneal endothelium during contact lens wear in vitro. Curr Eye Res 1995;14:311-318
    • (1995) Curr Eye Res , vol.14 , pp. 311-318
    • Giasson, C.1    Bonanno, J.A.2
  • 48
    • 0037335608 scopus 로고    scopus 로고
    • A mathematical model of tumor oxygen and glucose mass transport and metabolism with complex reaction kinetics
    • Kirkpatrick JP, Brizel DM, Dewhirst MW. A mathematical model of tumor oxygen and glucose mass transport and metabolism with complex reaction kinetics. Radiat Res 2003;159:336-344
    • (2003) Radiat Res , vol.159 , pp. 336-344
    • Kirkpatrick, J.P.1    Brizel, D.M.2    Dewhirst, M.W.3
  • 50
    • 0023232999 scopus 로고
    • The effect of corneal contact lenses on the oxygen tension in the anterior chamber of the rabbit eye
    • Stefansson E, Foulks GN, Hamilton RC. The effect of corneal contact lenses on the oxygen tension in the anterior chamber of the rabbit eye. Invest Ophthalmol Vis Sci 1987;28:1716-1719 (Pubitemid 17146740)
    • (1987) Investigative Ophthalmology and Visual Science , vol.28 , Issue.10 , pp. 1716-1719
    • Stefansson, E.1    Foulks, G.N.2    Hamilton, R.C.3
  • 51
    • 0015576985 scopus 로고
    • Effects of corneal environment on oxygen tension in the anterior chambers of rabbits
    • Barr RE, Silver IA. Effects of corneal environment on oxygen tension in the anterior chambers of rabbits. Invest Ophthalmol 1973;12: 140-144
    • (1973) Invest Ophthalmol , vol.12 , pp. 140-144
    • Barr, R.E.1    Silver, I.A.2
  • 54
    • 0014501421 scopus 로고
    • Sugar transport across the corneal endothelium
    • Hale PN, Maurice DM. Sugar transport across the corneal endothelium. Exp Eye Res 1969;8:205-215
    • (1969) Exp Eye Res , vol.8 , pp. 205-215
    • Hale, P.N.1    Maurice, D.M.2
  • 55
    • 0017095801 scopus 로고
    • The bicarbonate ion pump in the endothelium which regulates the hydration of rabbit cornea
    • Hodson S, Miller F. The bicarbonate ion pump in the endothelium which regulates the hydration of rabbit cornea. J Physiol 1976;263: 563-577 (Pubitemid 8025232)
    • (1976) Journal of Physiology , vol.263 , Issue.3 , pp. 563-577
    • Hodson, S.1    Miller, F.2
  • 56
    • 0025012490 scopus 로고
    • The pH in the precorneal tear film and under a contact lens measured with a fluorescent probe
    • DOI 10.1016/0014-4835(90)90209-D
    • Chen FS, Maurice DM. The pH in the precorneal tear film and under a contact lens measured with a fluorescent probe. Exp Eye Res 1990; 50:251-259 (Pubitemid 20081138)
    • (1990) Experimental Eye Research , vol.50 , Issue.3 , pp. 251-259
    • Chen, F.S.1    Maurice, D.M.2
  • 60
    • 0015302694 scopus 로고
    • Oxygen permeability of the limiting layers of the cornea
    • Freeman RD, Fatt I. Oxygen permeability of the limiting layers of the cornea. Biophys J 1972;12:237-247
    • (1972) Biophys J , vol.12 , pp. 237-247
    • Freeman, R.D.1    Fatt, I.2
  • 61
    • 0006865731 scopus 로고
    • Carbon dioxide permeability of contact lens materials
    • Ang JH, Efron N. Carbon dioxide permeability of contact lens materials. Int Contact Lens Clin 1989;16:48-58.
    • (1989) Int Contact Lens Clin , vol.16 , pp. 48-58
    • Ang, J.H.1    Efron, N.2
  • 62
    • 33646867222 scopus 로고    scopus 로고
    • Glucose permeability of human, bovine, and porcine corneas in vitro
    • DOI 10.1159/000090726
    • Myung D, Derr K, Huie P, Noolandi J, Ta KP, Ta CN. Glucose permeability of human, bovine, and porcine corneas in vitro. Ophthalmic Res 2006;38:158-163 (Pubitemid 43780875)
    • (2006) Ophthalmic Research , vol.38 , Issue.3 , pp. 158-163
    • Myung, D.1    Derr, K.2    Huie, P.3    Noolandi, J.4    Ta, K.P.5    Ta, C.N.6
  • 63
    • 0000575007 scopus 로고
    • A stirred bath technique for diffusivity measurements in cell matrices
    • Chresand TJ, Dale BE, Hanson SL, Gillies RJ. A stirred bath technique for diffusivity measurements in cell matrices. Biotechnol Bioeng 1988;32:1029-1036
    • (1988) Biotechnol Bioeng , vol.32 , pp. 1029-1036
    • Chresand, T.J.1    Dale, B.E.2    Hanson, S.L.3    Gillies, R.J.4
  • 64
    • 0031982563 scopus 로고    scopus 로고
    • Non-steady-state diffusion in a multilayered tissue initiated by manipulation of chemical activity at the boundaries
    • Fatt I, Giasson CJ, Mueller TD. Non-steady-state diffusion in a multilayered tissue initiated by manipulation of chemical activity at the boundaries. Biophys J 1998;74:475-486 (Pubitemid 28041775)
    • (1998) Biophysical Journal , vol.74 , Issue.1 , pp. 475-486
    • Fatt, I.1    Giasson, C.J.2    Mueller, T.D.3
  • 65
    • 0017338650 scopus 로고
    • Elimination of anions derived from glucose metabolism as substrates for the fluid pump of rabbit corneal endothelium
    • Riley MV, Miller F, Hodson S, Linz D. Elimination of anions derived from glucose metabolism as substrates for the fluid pump of rabbit corneal endothelium. Exp Eye Res 1977;24:255-261 (Pubitemid 8054258)
    • (1977) Experimental Eye Research , vol.24 , Issue.3 , pp. 255-261
    • Riley, M.V.1    Miller, F.2    Hodson, S.3    Linz, D.4
  • 66
    • 0021123317 scopus 로고
    • Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses
    • Holden BA, Mertz GW. Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses. Invest Ophthalmol Vis Sci 1984;25:1161-1167
    • (1984) Invest Ophthalmol Vis Sci , vol.25 , pp. 1161-1167
    • Holden, B.A.1    Mertz, G.W.2
  • 67
    • 0027570611 scopus 로고
    • EOP and Dk/L: The quest for hyper transmissibility
    • Benjamin WJ. EOP and Dk/L: the quest for hyper transmissibility. J Am Optom Assoc 1993;64:196-200.
    • (1993) J Am Optom Assoc , vol.64 , pp. 196-200
    • Benjamin, W.J.1
  • 68
    • 38249003255 scopus 로고
    • Is there a problem in EOP land?
    • Fatt I. Is there a problem in EOP land? Int Contact Lens Clin 1993; 20:150-154
    • (1993) Int Contact Lens Clin , vol.20 , pp. 150-154
    • Fatt, I.1
  • 69
    • 0029932917 scopus 로고    scopus 로고
    • Direct noninvasive measurement of tear oxygen tension beneath gas- Permeable contact lenses in rabbits
    • Harvitt DM, Bonanno JA. Direct noninvasive measurement of tear oxygen tension beneath gas-permeable contact lenses in rabbits. Invest Ophthalmol Vis Sci 1996;37:1026-1036 (Pubitemid 26164234)
    • (1996) Investigative Ophthalmology and Visual Science , vol.37 , Issue.6 , pp. 1026-1036
    • Harvitt, D.M.1    Bonanno, J.A.2
  • 70
    • 0142258103 scopus 로고    scopus 로고
    • Biological oxygen apparent transmissibility of hydrogel contact lenses with and without organosilicon moieties
    • DOI 10.1016/S0142-9612(03)00527-1
    • Compan V, Lopez-Alemany A, Riande E, Refojo MF. Biological oxygen apparent transmissibility of hydrogel contact lenses with and without organosilicon moieties. Biomaterials 2004;25:359-365 (Pubitemid 37329725)
    • (2004) Biomaterials , vol.25 , Issue.2 , pp. 359-365
    • Compan, V.1    Lopez-Alemany, A.2    Riande, E.3    Refojo, M.F.4
  • 71
    • 31944434499 scopus 로고    scopus 로고
    • A review of the Holden-Mertz criteria for critical oxygen transmission
    • DOI 10.1097/01.icl.0000182488.70745.1d
    • Fonn D, Bruce AS. A review of the Holden-Mertz criteria for critical oxygen transmission. Eye Contact Lens 2005;31:247-251 (Pubitemid 43189097)
    • (2005) Eye and Contact Lens , vol.31 , Issue.6 , pp. 247-251
    • Fonn, D.1    Bruce, A.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.