Volumn 62, Issue 1, 2009, Pages 66-76

SEMAC: Slice encoding for metal artifact correction in MRI

Author keywords

Distorted excitation profiles; Distortion correction; Field inhomogeneities; Metal artifacts; Metal induced distortions; Metallic implants; Susceptibility artifact; View angle tilting

Indexed keywords

ENCODING (SYMBOLS); IMAGE SEGMENTATION; MAGNETIC RESONANCE IMAGING; SIGNAL ENCODING;

EID: 67650085839     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.21967     Document Type: Article
Times cited : (328)

References (28)
  • 1
    • 21444440419 scopus 로고    scopus 로고
    • Prevalence of primary and revision total hip and knee arthroplasty in the united states from 1990 through 2002
    • Kurtz S, Mowat F, Ong K, Chan N, Lau E, Halpern M. Prevalence of primary and revision total hip and knee arthroplasty in the united states from 1990 through 2002. J Bone Joint Surg Am 2005;87:1487-1497.
    • (2005) J Bone Joint Surg Am , vol.87 , pp. 1487-1497
    • Kurtz, S.1    Mowat, F.2    Ong, K.3    Chan, N.4    Lau, E.5    Halpern, M.6
  • 2
    • 67650035828 scopus 로고    scopus 로고
    • Resnick D. Diagnosis of bone and joint disorders. New York: Saunders; 2002.
    • Resnick D. Diagnosis of bone and joint disorders. New York: Saunders; 2002.
  • 4
    • 23744475809 scopus 로고    scopus 로고
    • MR imaging of soft tissues adjacent to orthopaedic hardware: Techniques to minimize susceptibility artefact
    • Eustace S, Goldberg R, Williamson D, Melhem ER, Oladipo O, Yucel EK, Jara H. MR imaging of soft tissues adjacent to orthopaedic hardware: Techniques to minimize susceptibility artefact. Clin Radiol 1997;52:589-594.
    • (1997) Clin Radiol , vol.52 , pp. 589-594
    • Eustace, S.1    Goldberg, R.2    Williamson, D.3    Melhem, E.R.4    Oladipo, O.5    Yucel, E.K.6    Jara, H.7
  • 7
    • 0029184004 scopus 로고
    • Nonsusceptibility artifacts due to metallic objects inMRimaging
    • Camacho CR, Plewes DB, Henkelman RM. Nonsusceptibility artifacts due to metallic objects inMRimaging. JMagn Reson Imaging 1995;5:75-88.
    • (1995) JMagn Reson Imaging , vol.5 , pp. 75-88
    • Camacho, C.R.1    Plewes, D.B.2    Henkelman, R.M.3
  • 8
    • 21244506736 scopus 로고    scopus 로고
    • Correction of MR image distortions induced by metallic objects using a 3D cubic B-Spline basis set: Application to stereotactic surgical planning
    • Skare S, Anderson J. Correction of MR image distortions induced by metallic objects using a 3D cubic B-Spline basis set: Application to stereotactic surgical planning. Magn Reson Med 2005;54:169-181.
    • (2005) Magn Reson Med , vol.54 , pp. 169-181
    • Skare, S.1    Anderson, J.2
  • 11
    • 0023883943 scopus 로고
    • Total inhomogeneity correction including chemical shifts and susceptibility by view angle tilting
    • Cho ZH, Kim DJ, Kim YK. Total inhomogeneity correction including chemical shifts and susceptibility by view angle tilting. Med Phys 1988;15:7-11.
    • (1988) Med Phys , vol.15 , pp. 7-11
    • Cho, Z.H.1    Kim, D.J.2    Kim, Y.K.3
  • 12
    • 12844254477 scopus 로고    scopus 로고
    • Reduction of blurring in view angle tilting MRI
    • Butts K, Pauly JM, Gold GE. Reduction of blurring in view angle tilting MRI. Magn Reson Med 2005;53:418-24.
    • (2005) Magn Reson Med , vol.53 , pp. 418-424
    • Butts, K.1    Pauly, J.M.2    Gold, G.E.3
  • 19
    • 0345830059 scopus 로고    scopus 로고
    • Metallic artefacts in MR imaging: Effects of main field orientation and strength
    • Guermazi A, Miaux Y, Zaim S, Peterfy C, White D, Genant HK. Metallic artefacts in MR imaging: Effects of main field orientation and strength. Clin Radiol 2003;58:322-328.
    • (2003) Clin Radiol , vol.58 , pp. 322-328
    • Guermazi, A.1    Miaux, Y.2    Zaim, S.3    Peterfy, C.4    White, D.5    Genant, H.K.6
  • 20
    • 7544240906 scopus 로고    scopus 로고
    • MRI of hip prostheses using single-point methods: In vitro studies towards the artifact-free imaging of individuals with metal implants
    • Graf H, Steidle G, Martirosian P, Lauer UA, Schick F. MRI of hip prostheses using single-point methods: In vitro studies towards the artifact-free imaging of individuals with metal implants. Magn Reson Imaging 2004;22:1097-1103.
    • (2004) Magn Reson Imaging , vol.22 , pp. 1097-1103
    • Graf, H.1    Steidle, G.2    Martirosian, P.3    Lauer, U.A.4    Schick, F.5
  • 21
    • 0032868199 scopus 로고    scopus 로고
    • 3D z-shim method for reduction of susceptibility effects in BOLD fMRI
    • Glover GH. 3D z-shim method for reduction of susceptibility effects in BOLD fMRI. Magn Reson Med 1999;42:290-299.
    • (1999) Magn Reson Med , vol.42 , pp. 290-299
    • Glover, G.H.1
  • 22
    • 0032768601 scopus 로고    scopus 로고
    • Composite image formation in z-shimmed functional MR imaging
    • Constable RT, Spencer DD. Composite image formation in z-shimmed functional MR imaging. Magn Reson Med 1999;42:110-117.
    • (1999) Magn Reson Med , vol.42 , pp. 110-117
    • Constable, R.T.1    Spencer, D.D.2
  • 24
    • 33646449765 scopus 로고    scopus 로고
    • Fast spin echo sequences with very long echo trains: Design of variable refocusing flip angle schedules and generation of clinical t2 contrast
    • Busse RF, Hariharan H, Vu A, Brittain JH. Fast spin echo sequences with very long echo trains: Design of variable refocusing flip angle schedules and generation of clinical t2 contrast. Magn Reson Med 2006;55:1030-1037.
    • (2006) Magn Reson Med , vol.55 , pp. 1030-1037
    • Busse, R.F.1    Hariharan, H.2    Vu, A.3    Brittain, J.H.4
  • 28
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: The application of compressed sensing for rapid MR imaging
    • Lustig M, Donoho D, Pauly JM. Sparse MRI: The application of compressed sensing for rapid MR imaging. Magn Reson Med 2007;58:1182-1195.
    • (2007) Magn Reson Med , vol.58 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.