Volumn 140, Issue 2, 2009, Pages 603-609

A MEMS affinity glucose sensor using a biocompatible glucose-responsive polymer

Author keywords

Affinity binding; Biocompatibility; Biosensors; Continuous glucose monitoring; Diabetes; MEMS; Viscometry

Indexed keywords

ACRYLAMIDE; AFFINITY BINDING; AFFINITY SENSOR; CANTILEVER VIBRATIONS; CONTINUOUS GLUCOSE MONITORING; DEVICE DESIGN; DIABETES; DIABETES MANAGEMENT; GLUCOSE CONCENTRATION; GLUCOSE RESPONSE; GLUCOSE-RESPONSIVE; LONG-TERM CONTINUOUS MONITORING; MICRO-CANTILEVER; MICRO-CHAMBER; OPTICAL LEVER; PARYLENE; PHENYLBORONIC ACIDS; SEMI-PERMEABLE MEMBRANES; SENSING ELEMENTS; SENSING PRINCIPLE; SENSOR RESPONSE; SUBCUTANEOUS TISSUES; VISCOMETRY;

EID: 67649385565     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2009.04.065     Document Type: Article
Times cited : (82)

References (27)
  • 2
    • 33846111973 scopus 로고    scopus 로고
    • The accuracy of the FreeStyle Navigator Continuous Glucose Monitoring System in children with type 1 diabetes
    • Wilson D.M., Beck R.W., Tamborlane W.V., et al. The accuracy of the FreeStyle Navigator Continuous Glucose Monitoring System in children with type 1 diabetes. Diabetes Care 30 (2007) 59-64
    • (2007) Diabetes Care , vol.30 , pp. 59-64
    • Wilson, D.M.1    Beck, R.W.2    Tamborlane, W.V.3
  • 3
    • 50849090588 scopus 로고    scopus 로고
    • Real-time glucose sensors in children and adolescents with type-1 diabetes
    • Danne T., Lange K., and Kordonouri O. Real-time glucose sensors in children and adolescents with type-1 diabetes. Hormone Research 70 (2008) 193-202
    • (2008) Hormone Research , vol.70 , pp. 193-202
    • Danne, T.1    Lange, K.2    Kordonouri, O.3
  • 4
    • 0033302247 scopus 로고    scopus 로고
    • Implanted electrochemical glucose sensors for the management of diabetes
    • Heller A. Implanted electrochemical glucose sensors for the management of diabetes. Annual Review of Biomedical Engineering 1 (1999) 153-175
    • (1999) Annual Review of Biomedical Engineering , vol.1 , pp. 153-175
    • Heller, A.1
  • 5
    • 33745822012 scopus 로고    scopus 로고
    • On-line coupling of size exclusion chromatography and capillary electrophoresis via solid-phase extraction and a Tee-split interface
    • Tempels F.W.A., Wiese G., and Underberg W.J.M. On-line coupling of size exclusion chromatography and capillary electrophoresis via solid-phase extraction and a Tee-split interface. Journal of Chromatography B 839 (2006) 30-35
    • (2006) Journal of Chromatography B , vol.839 , pp. 30-35
    • Tempels, F.W.A.1    Wiese, G.2    Underberg, W.J.M.3
  • 6
    • 0032063926 scopus 로고    scopus 로고
    • On line dual microdialysis with ESI-MS for direct analysis of complex biological samples and microorganism lysates
    • Liu C.L., Hofstadler S.A., Bresson J.A., et al. On line dual microdialysis with ESI-MS for direct analysis of complex biological samples and microorganism lysates. Analytical Chemistry 70 May (9) (1998) 1797-1801
    • (1998) Analytical Chemistry , vol.70 , Issue.May 9 , pp. 1797-1801
    • Liu, C.L.1    Hofstadler, S.A.2    Bresson, J.A.3
  • 7
    • 0028148673 scopus 로고
    • Suitability of aqueous dispersions of dextran and Concanavalin A for glucose sensing in different variants of the affinity sensor
    • Ballerstadt R., and Ehwald R. Suitability of aqueous dispersions of dextran and Concanavalin A for glucose sensing in different variants of the affinity sensor. Biosensors & Bioelectronics 9 (1994) 557-567
    • (1994) Biosensors & Bioelectronics , vol.9 , pp. 557-567
    • Ballerstadt, R.1    Ehwald, R.2
  • 8
    • 0020037173 scopus 로고
    • Affinity sensor-a new technique for developing implantable sensors for glucose and other metabolites
    • Schultz J.S., Mansouri S., and Goldstein I.J. Affinity sensor-a new technique for developing implantable sensors for glucose and other metabolites. Diabetes Care 5 3 (1982) 245-253
    • (1982) Diabetes Care , vol.5 , Issue.3 , pp. 245-253
    • Schultz, J.S.1    Mansouri, S.2    Goldstein, I.J.3
  • 9
    • 0019966434 scopus 로고
    • Immunogenicity and amplifier cell production by tumor vaccines enhanced by Concanavalin A
    • Kataoka T., Oh-Hashi F., and Sakurai Y. Immunogenicity and amplifier cell production by tumor vaccines enhanced by Concanavalin A. Gann 73 (1982) 193-205
    • (1982) Gann , vol.73 , pp. 193-205
    • Kataoka, T.1    Oh-Hashi, F.2    Sakurai, Y.3
  • 10
    • 0023395014 scopus 로고
    • Studies on the effect of Concanavalin A on the metabolism of low density lipoproteins in skin fibroblasts
    • Matsuura H., Ranganathan S., Yamamoto M., et al. Studies on the effect of Concanavalin A on the metabolism of low density lipoproteins in skin fibroblasts. Japanese Journal of Medicine 26 (1987) 323-325
    • (1987) Japanese Journal of Medicine , vol.26 , pp. 323-325
    • Matsuura, H.1    Ranganathan, S.2    Yamamoto, M.3
  • 11
    • 0032501420 scopus 로고    scopus 로고
    • Totally synthetic polymer gels responding to external glucose concentration: their preparation and application to on-off regulation of insulin-release
    • Kataoka K., and Matsumoto A. Totally synthetic polymer gels responding to external glucose concentration: their preparation and application to on-off regulation of insulin-release. Journal of the American Chemical Society 120 48 (1998) 12694-12695
    • (1998) Journal of the American Chemical Society , vol.120 , Issue.48 , pp. 12694-12695
    • Kataoka, K.1    Matsumoto, A.2
  • 12
    • 0029902912 scopus 로고    scopus 로고
    • Saccharide sensing with molecular receptors based on boronic acid
    • (International edition in English)
    • James T.D., Sandanayake K.R.A.S., and Shinkai S. Saccharide sensing with molecular receptors based on boronic acid. Angewandte Chemie 35 (1996) 1910-1922 (International edition in English)
    • (1996) Angewandte Chemie , vol.35 , pp. 1910-1922
    • James, T.D.1    Sandanayake, K.R.A.S.2    Shinkai, S.3
  • 13
    • 24144443786 scopus 로고    scopus 로고
    • Boronolectins and fluorescent boronolectins: an examination of the detailed chemistry issues important for the design
    • Yan J., Fang H., and Wang B. Boronolectins and fluorescent boronolectins: an examination of the detailed chemistry issues important for the design. Medicinal Research Reviews 25 (2005) 490-520
    • (2005) Medicinal Research Reviews , vol.25 , pp. 490-520
    • Yan, J.1    Fang, H.2    Wang, B.3
  • 14
    • 33645298033 scopus 로고    scopus 로고
    • A hydrogel-based implantable micromachined transponder for wireless glucose measurement
    • Lei M., Baldi A., Nuxoll E., et al. A hydrogel-based implantable micromachined transponder for wireless glucose measurement. Diabetes Technology & Therapeutics 8 (2006) 112-122
    • (2006) Diabetes Technology & Therapeutics , vol.8 , pp. 112-122
    • Lei, M.1    Baldi, A.2    Nuxoll, E.3
  • 15
    • 0033978399 scopus 로고    scopus 로고
    • A membrane-moderated, conductimetric sensor for the detection and measurement of specific organic solutes in aqueous solutions
    • Arnold F.H., Zheng W., and Michaels A.S. A membrane-moderated, conductimetric sensor for the detection and measurement of specific organic solutes in aqueous solutions. Journal of Membrane Science 167 (2000) 227-239
    • (2000) Journal of Membrane Science , vol.167 , pp. 227-239
    • Arnold, F.H.1    Zheng, W.2    Michaels, A.S.3
  • 16
    • 58549099502 scopus 로고    scopus 로고
    • Development of boronic acid grafted random copolymer sensing fluid for continuous glucose monitoring
    • Li S., Davis E.N., Anderson J., et al. Development of boronic acid grafted random copolymer sensing fluid for continuous glucose monitoring. Biomacromolecules 10 (2009) 113-118
    • (2009) Biomacromolecules , vol.10 , pp. 113-118
    • Li, S.1    Davis, E.N.2    Anderson, J.3
  • 17
    • 0033673135 scopus 로고    scopus 로고
    • Miniaturized electroanalytical sensor systems in micromachined structures
    • Cai X.X., Glidle A., and Cooper J.M. Miniaturized electroanalytical sensor systems in micromachined structures. Electroanalysis 12 9 (2000) 631-639
    • (2000) Electroanalysis , vol.12 , Issue.9 , pp. 631-639
    • Cai, X.X.1    Glidle, A.2    Cooper, J.M.3
  • 18
    • 3042739491 scopus 로고    scopus 로고
    • Application of a new Cl-plasma-treated Ag/AgCl reference electrode to micromachined glucose sensor
    • Park S.I., Jun S.B., Park S., et al. Application of a new Cl-plasma-treated Ag/AgCl reference electrode to micromachined glucose sensor. IEEE Sensors Journal 3 3 (2003) 267-273
    • (2003) IEEE Sensors Journal , vol.3 , Issue.3 , pp. 267-273
    • Park, S.I.1    Jun, S.B.2    Park, S.3
  • 19
    • 67649327033 scopus 로고    scopus 로고
    • Study on sensing system configuration by MEMS technology
    • Chinami K., Akira Y., Keishin K., et al. Study on sensing system configuration by MEMS technology. IEIC Technical Report 104 (2004) 13-18
    • (2004) IEIC Technical Report , vol.104 , pp. 13-18
    • Chinami, K.1    Akira, Y.2    Keishin, K.3
  • 20
    • 0034212524 scopus 로고    scopus 로고
    • Microfabricated electrophoresis chips for simultaneous bioassays of glucose, uric acid, ascorbic acid, and acetaminophen
    • Wang J., Chatrathi M.P., Tian B.M., et al. Microfabricated electrophoresis chips for simultaneous bioassays of glucose, uric acid, ascorbic acid, and acetaminophen. Analytical Chemistry 72 110 (2000) 2514-2518
    • (2000) Analytical Chemistry , vol.72 , Issue.110 , pp. 2514-2518
    • Wang, J.1    Chatrathi, M.P.2    Tian, B.M.3
  • 21
    • 0034038899 scopus 로고    scopus 로고
    • Mini/micro thermal biosensors and other related devices for biochemical/clinical analysis and monitoring
    • Xie B., Ramanathan K., and Danielsson B. Mini/micro thermal biosensors and other related devices for biochemical/clinical analysis and monitoring. Trends in Analytical Chemistry 19 (2000) 340-349
    • (2000) Trends in Analytical Chemistry , vol.19 , pp. 340-349
    • Xie, B.1    Ramanathan, K.2    Danielsson, B.3
  • 22
    • 0027423044 scopus 로고
    • Calorimetric sensing in bioanalytical chemistry: principles, applications and trends
    • Bataillard P. Calorimetric sensing in bioanalytical chemistry: principles, applications and trends. Trends in Analytical Chemistry 12 (1993) 387-394
    • (1993) Trends in Analytical Chemistry , vol.12 , pp. 387-394
    • Bataillard, P.1
  • 23
    • 0034135607 scopus 로고    scopus 로고
    • A surface-micromachined optical self-homodyne polarimetric sensor for noninvasive glucose monitoring
    • Pu C., Zhu Z.H., and Lo Y.H. A surface-micromachined optical self-homodyne polarimetric sensor for noninvasive glucose monitoring. IEEE Photonics Technology Letters 12 2 (2000) 190-192
    • (2000) IEEE Photonics Technology Letters , vol.12 , Issue.2 , pp. 190-192
    • Pu, C.1    Zhu, Z.H.2    Lo, Y.H.3
  • 24
    • 0038392907 scopus 로고    scopus 로고
    • A PDMS dermal patch for non-intrusive transdermal glucose sensing
    • Paranjape M., Garra J., Brida S., et al. A PDMS dermal patch for non-intrusive transdermal glucose sensing. Sensors and Actuators a-Physical 104 3 (2003 May) 195-204
    • (2003) Sensors and Actuators a-Physical , vol.104 , Issue.3 , pp. 195-204
    • Paranjape, M.1    Garra, J.2    Brida, S.3
  • 25
    • 1642550407 scopus 로고    scopus 로고
    • Microfluidic devices on polymer substrates for bioanalytical applications
    • Ehrfeld W. (Ed), Springer-Verlag
    • Lin Y., Matson D.W., Kurath D.E., et al. Microfluidic devices on polymer substrates for bioanalytical applications. In: Ehrfeld W. (Ed). Microreaction Technology: Industrial Prospects (2000), Springer-Verlag 451-460
    • (2000) Microreaction Technology: Industrial Prospects , pp. 451-460
    • Lin, Y.1    Matson, D.W.2    Kurath, D.E.3
  • 27
    • 84887265351 scopus 로고    scopus 로고
    • Development of novel glucose sensing fluids with potential application to microelectromechanical systems-based continuous glucose monitoring
    • Li S., Huang X., Davis E.N., et al. Development of novel glucose sensing fluids with potential application to microelectromechanical systems-based continuous glucose monitoring. Journal of Diabetes Science and Technology 2 6 (2008) 1066-1074
    • (2008) Journal of Diabetes Science and Technology , vol.2 , Issue.6 , pp. 1066-1074
    • Li, S.1    Huang, X.2    Davis, E.N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.