-
1
-
-
0027998781
-
-
The effect of intensive diabetes treatment on the development and progression of longterm complications in adolescents with insulin-dependent diabetes mellitus: the Diabetes Control and Complications Trial. Diabetes Control and Complications Trial Research Group. J Pediatr 1994;125:177-188
-
The effect of intensive diabetes treatment on the development and progression of longterm complications in adolescents with insulin-dependent diabetes mellitus: the Diabetes Control and Complications Trial. Diabetes Control and Complications Trial Research Group. J Pediatr 1994;125:177-188.
-
-
-
-
2
-
-
0035663189
-
Diabetes Control and Complications Trial (DCCT)/Epidemiology of Diabetes Interventions and Complications (EDIC) Research Group: Beneficial effects of intensive therapy of diabetes during adolescence: outcomes after the conclusion of the Diabetes Control and Complications Trial (DCCT)
-
White NH, Cleary PA, Dahms W, Goldstein D, Malone J, Tamborlane WV; Diabetes Control and Complications Trial (DCCT)/Epidemiology of Diabetes Interventions and Complications (EDIC) Research Group: Beneficial effects of intensive therapy of diabetes during adolescence: outcomes after the conclusion of the Diabetes Control and Complications Trial (DCCT). J Pediatr 2001;139:804-812.
-
(2001)
J Pediatr
, vol.139
, pp. 804-812
-
-
White, N.H.1
Cleary, P.A.2
Dahms, W.3
Goldstein, D.4
Malone, J.5
Tamborlane, W.V.6
-
3
-
-
44449120061
-
Relationship of A1C to glucose concentrations in children with type 1 diabetes: Assessments by high frequency glucose determinations by sensors
-
Diabetes Research in Children Network (DirecNet) Study Group
-
Diabetes Research in Children Network (DirecNet) Study Group, Wilson DM, Kollman C: Relationship of A1C to glucose concentrations in children with type 1 diabetes: assessments by high frequency glucose determinations by sensors. Diabetes Care 2008;31:381-385.
-
(2008)
Diabetes Care
, vol.31
, pp. 381-385
-
-
Wilson, D.M.1
Kollman, C.2
-
4
-
-
53549092190
-
-
Heller S, Kim H, Draeger E: Within-person variation in fasting blood glucose is correlated to incidence of hypoglycemia in people with type 1 diabetes treated with insulin detemir and NPH insulin. Diabetologia 2004;47S1:A303.
-
Heller S, Kim H, Draeger E: Within-person variation in fasting blood glucose is correlated to incidence of hypoglycemia in people with type 1 diabetes treated with insulin detemir and NPH insulin. Diabetologia 2004;47S1:A303.
-
-
-
-
5
-
-
0014848738
-
Mean amplitude of glycemic excursions, a measure of diabetic instability
-
Service FJ
-
Service FJ, Molnar GD, Rosevear JW, Ackermann E, Gatweood LC, Taylor WF: Mean amplitude of glycemic excursions, a measure of diabetic instability. Diabetes 1970;19:644-655.
-
(1970)
Diabetes
, vol.19
, pp. 644-655
-
-
Molnar, G.D.1
Rosevear, J.W.2
Ackermann, E.3
Gatweood, L.C.4
Taylor, W.F.5
-
6
-
-
33645728965
-
Assessing glycemia in diabetes using self-monitoring blood glucose and hemoglobin A1c
-
Saudek CD, Derr RL, Kalyani RR: Assessing glycemia in diabetes using self-monitoring blood glucose and hemoglobin A1c. JAMA 2006;295:1688-1697.
-
(2006)
JAMA
, vol.295
, pp. 1688-1697
-
-
Saudek, C.D.1
Derr, R.L.2
Kalyani, R.R.3
-
7
-
-
35748960486
-
New developments in the treatment of type 1 diabetes in children
-
Danne T, Lange K, Kordonouri O: New developments in the treatment of type 1 diabetes in children. Arch Dis Child 2007;92:1015-1019.
-
(2007)
Arch Dis Child
, vol.92
, pp. 1015-1019
-
-
Danne, T.1
Lange, K.2
Kordonouri, O.3
-
8
-
-
33645732339
-
Glycemic variability: A hemoglobin A1c-independent risk factor for diabetic complications
-
Brownlee M, Hirsch IB: Glycemic variability: a hemoglobin A1c-independent risk factor for diabetic complications. JAMA 2006;295:1707-1708.
-
(2006)
JAMA
, vol.295
, pp. 1707-1708
-
-
Brownlee, M.1
Hirsch, I.B.2
-
9
-
-
0037518410
-
Glucose sensor evaluation of glycemic instability in pediatric type 1 diabetes mellitus
-
Alemzadeh R, Loppnow C, Parton E, Kirby M: Glucose sensor evaluation of glycemic instability in pediatric type 1 diabetes mellitus. Diabetes Technol Ther 2003;5:167-173.
-
(2003)
Diabetes Technol Ther
, vol.5
, pp. 167-173
-
-
Alemzadeh, R.1
Loppnow, C.2
Parton, E.3
Kirby, M.4
-
10
-
-
1842527586
-
Assessment of the severity of hypoglycemia and glycemic lability in type 1 diabetic subjects undergoing islet transplantation
-
Ryan EA, Shandro T, Green K, Paty BW, Senior PA, Bigam D, Shapiro AM, Vantyghem MC: Assessment of the severity of hypoglycemia and glycemic lability in type 1 diabetic subjects undergoing islet transplantation. Diabetes 2004;53:955-962.
-
(2004)
Diabetes
, vol.53
, pp. 955-962
-
-
Ryan, E.A.1
Shandro, T.2
Green, K.3
Paty, B.W.4
Senior, P.A.5
Bigam, D.6
Shapiro, A.M.7
Vantyghem, M.C.8
-
11
-
-
0034117324
-
Performance evaluation of the MiniMed continuous glucose monitoring system during patient home use
-
Gross TM, Bode BW, Einhorn D, Kayne DM, Reed JH, White NH, Mastrototaro JJ: Performance evaluation of the MiniMed continuous glucose monitoring system during patient home use. Diabetes Technol Ther 2000;2:49-56.
-
(2000)
Diabetes Technol Ther
, vol.2
, pp. 49-56
-
-
Gross, T.M.1
Bode, B.W.2
Einhorn, D.3
Kayne, D.M.4
Reed, J.H.5
White, N.H.6
Mastrototaro, J.J.7
-
13
-
-
1842583012
-
Alarms based on real-time sensor glucose values alert patients to hypo- and hyperglycemia: The guardian continuous monitoring system
-
Bode B, Gross K, Rikalo N, Schwartz S, Wahl T, Page C, Gross T, Mastrototaro J: Alarms based on real-time sensor glucose values alert patients to hypo- and hyperglycemia: the guardian continuous monitoring system. Diabetes Technol Ther 2004;6:105-113.
-
(2004)
Diabetes Technol Ther
, vol.6
, pp. 105-113
-
-
Bode, B.1
Gross, K.2
Rikalo, N.3
Schwartz, S.4
Wahl, T.5
Page, C.6
Gross, T.7
Mastrototaro, J.8
-
14
-
-
0036481429
-
Continuous subcutaneous glucose monitoring in diabetic patients: A multicenter analysis
-
Maran A, Crepaldi C, Tiengo A, Grassi G, Vitali E, Pagano G, Bistoni S, Calabrese G, Santeusanio F, Leonetti F, Ribaudo M, Di Mario U, Annuzzi G, Genovese S, Riccardi G, Previti M, Cucinotta D, Giorgino F, Bellomo A, Giorgino R, Poscia A, Varalli M: Continuous subcutaneous glucose monitoring in diabetic patients: a multicenter analysis. Diabetes Care 2002;25:347-352.
-
(2002)
Diabetes Care
, vol.25
, pp. 347-352
-
-
Maran, A.1
Crepaldi, C.2
Tiengo, A.3
Grassi, G.4
Vitali, E.5
Pagano, G.6
Bistoni, S.7
Calabrese, G.8
Santeusanio, F.9
Leonetti, F.10
Ribaudo, M.11
Di Mario, U.12
Annuzzi, G.13
Genovese, S.14
Riccardi, G.15
Previti, M.16
Cucinotta, D.17
Giorgino, F.18
Bellomo, A.19
Giorgino, R.20
Poscia, A.21
Varalli, M.22
more..
-
15
-
-
4344615386
-
Impact of posture and fixation technique on impedance spectroscopy used for continuous and non-invasive glucose monitoring
-
Pfuetzner A, Caduff A, Larbig M, Schrepfer T, Forst T: Impact of posture and fixation technique on impedance spectroscopy used for continuous and non-invasive glucose monitoring. Diabetes Technol Ther 2004;6:435-441.
-
(2004)
Diabetes Technol Ther
, vol.6
, pp. 435-441
-
-
Pfuetzner, A.1
Caduff, A.2
Larbig, M.3
Schrepfer, T.4
Forst, T.5
-
16
-
-
0242363717
-
A continuous glucose sensor based on wired enzyme technology: Results from a 3-day trial in patients with type 1 diabetes
-
Feldman B, Brazg R, Schwartz S, Weinstein R: A continuous glucose sensor based on wired enzyme technology: results from a 3-day trial in patients with type 1 diabetes. Diabetes Technol Ther 2003;5:769-779.
-
(2003)
Diabetes Technol Ther
, vol.5
, pp. 769-779
-
-
Feldman, B.1
Brazg, R.2
Schwartz, S.3
Weinstein, R.4
-
17
-
-
34250776500
-
Reduction in hemoglobin A1C with real-time continuous glucose monitoring: Results from a 12-week observational study
-
Bailey TS, Zisser HC, Garg SK: Reduction in hemoglobin A1C with real-time continuous glucose monitoring: results from a 12-week observational study. Diabetes Technol Ther 2007;9:203-210.
-
(2007)
Diabetes Technol Ther
, vol.9
, pp. 203-210
-
-
Bailey, T.S.1
Zisser, H.C.2
Garg, S.K.3
-
19
-
-
0031036953
-
Noninvasive blood glucose monitoring
-
Klonoff DC: Noninvasive blood glucose monitoring. Diabetes Care 1997;20:433-437.
-
(1997)
Diabetes Care
, vol.20
, pp. 433-437
-
-
Klonoff, D.C.1
-
20
-
-
0033552348
-
In vivo glucose sensing for diabetes management: Progress towards non-invasive monitoring. Interview by Judy Jones
-
Pickup J, McCartney L, Rolinski L, Birch D: In vivo glucose sensing for diabetes management: progress towards non-invasive monitoring. Interview by Judy Jones. BMJ 1999;319:1289-1293.
-
(1999)
BMJ
, vol.319
, pp. 1289-1293
-
-
Pickup, J.1
McCartney, L.2
Rolinski, L.3
Birch, D.4
-
21
-
-
0031864724
-
Non-invasive continuous glucose monitoring in type I diabetic patients with optical glucose sensors. Non-Invasive Task Force (NITF)
-
Heinemann L, Schmelzeisen-Redeker G: Non-invasive continuous glucose monitoring in type I diabetic patients with optical glucose sensors. Non-Invasive Task Force (NITF). Diabetologia 1998;41:848-854.
-
(1998)
Diabetologia
, vol.41
, pp. 848-854
-
-
Heinemann, L.1
Schmelzeisen-Redeker, G.2
-
22
-
-
0033366694
-
Transcutaneous glucose measurement using near-infrared spectroscopy during hypoglycemia
-
Gabriely I, Wozniak R, Mevorach M, Kaplan J, Aharon Y, Shamoon H: Transcutaneous glucose measurement using near-infrared spectroscopy during hypoglycemia. Diabetes Care 1999;22:2026-2032.
-
(1999)
Diabetes Care
, vol.22
, pp. 2026-2032
-
-
Gabriely, I.1
Wozniak, R.2
Mevorach, M.3
Kaplan, J.4
Aharon, Y.5
Shamoon, H.6
-
23
-
-
0026668743
-
Noninvasive glucose monitoring in diabetic patients: A preliminary evaluation
-
Robinson MR, Eaton RP, Haaland DM, et al: Noninvasive glucose monitoring in diabetic patients: a preliminary evaluation. Clin Chem 1992;38:1618-1622.
-
(1992)
Clin Chem
, vol.38
, pp. 1618-1622
-
-
Robinson, M.R.1
Eaton, R.P.2
Haaland, D.M.3
-
24
-
-
0033859245
-
Transcutaneous glucose measurement using near-infrared spectroscopy: Validation of statistical calibration models
-
Heise HM, Lampen P: Transcutaneous glucose measurement using near-infrared spectroscopy: validation of statistical calibration models. Diabetes Care 2000;23:1208-1210.
-
(2000)
Diabetes Care
, vol.23
, pp. 1208-1210
-
-
Heise, H.M.1
Lampen, P.2
-
25
-
-
0034061329
-
Transdermal monitoring of glucose and other analytes using ultrasound
-
Kost J, Mitragotri S, Gabbay RA, Pishko M, Langer R: Transdermal monitoring of glucose and other analytes using ultrasound. Nat Med 2000;6:347-350.
-
(2000)
Nat Med
, vol.6
, pp. 347-350
-
-
Kost, J.1
Mitragotri, S.2
Gabbay, R.A.3
Pishko, M.4
Langer, R.5
-
26
-
-
0027754155
-
Glucose determination by a pulsed photoacoustic technique: An experimental study using a gelatin-based tissue phantom
-
Quan KM, Christison GB, Mackenzie HA, Hodgson P: Glucose determination by a pulsed photoacoustic technique: an experimental study using a gelatin-based tissue phantom. Phys Med Biol 1993;38:1911-1922.
-
(1993)
Phys Med Biol
, vol.38
, pp. 1911-1922
-
-
Quan, K.M.1
Christison, G.B.2
Mackenzie, H.A.3
Hodgson, P.4
-
27
-
-
0033579205
-
Noninvasive glucose monitoring: Comprehensive clinical results. Cygnus Research Team
-
Tamada JA, Garg SK, Jovanovic L, Pitzer KR, Fermi SJ, Potts RO: Noninvasive glucose monitoring: comprehensive clinical results. Cygnus Research Team. JAMA 1999;282:1839-1844.
-
(1999)
JAMA
, vol.282
, pp. 1839-1844
-
-
Tamada, J.A.1
Garg, S.K.2
Jovanovic, L.3
Pitzer, K.R.4
Fermi, S.J.5
Potts, R.O.6
-
28
-
-
0032882086
-
Correlation of finger-stick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with type 1 diabetes
-
Garg SK, Potts RO, Ackerman NR, Fermi SJ, Tamada JA, Chase HP: Correlation of finger-stick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with type 1 diabetes. Diabetes Care 1999;22:1708-1714.
-
(1999)
Diabetes Care
, vol.22
, pp. 1708-1714
-
-
Garg, S.K.1
Potts, R.O.2
Ackerman, N.R.3
Fermi, S.J.4
Tamada, J.A.5
Chase, H.P.6
-
29
-
-
18144373420
-
A randomized multicenter trial comparing the GlucoWatch Biographer with standard glucose monitoring in children with type 1 diabetes
-
Chase HP, Beck R, Tamborlane W, et al: A randomized multicenter trial comparing the GlucoWatch Biographer with standard glucose monitoring in children with type 1 diabetes. Diabetes Care 2005;28:1101-1106.
-
(2005)
Diabetes Care
, vol.28
, pp. 1101-1106
-
-
Chase, H.P.1
Beck, R.2
Tamborlane, W.3
-
30
-
-
6044276738
-
Diabetes Research in Children Network (DirecNet) Study Group: GlucoWatch G2 Biographer alarm reliability during hypoglycemia in children
-
Tsalikian E, Kollman C, Mauras N, Weinzimer S, Buckingham B, Xing D, Beck R, Ruedy K, Tamborlane W, Fiallo-Scharer R; Diabetes Research in Children Network (DirecNet) Study Group: GlucoWatch G2 Biographer alarm reliability during hypoglycemia in children. Diabetes Technol Ther 2004;6:559-565.
-
(2004)
Diabetes Technol Ther
, vol.6
, pp. 559-565
-
-
Tsalikian, E.1
Kollman, C.2
Mauras, N.3
Weinzimer, S.4
Buckingham, B.5
Xing, D.6
Beck, R.7
Ruedy, K.8
Tamborlane, W.9
Fiallo-Scharer, R.10
-
31
-
-
0027425609
-
Long-term continuous glucose monitoring with microdialysis in ambulatory insulin-dependent diabetic patients
-
Bolinder J, Ungerstedt U, Arner P: Long-term continuous glucose monitoring with microdialysis in ambulatory insulin-dependent diabetic patients. Lancet 1993;342:1080-1085.
-
(1993)
Lancet
, vol.342
, pp. 1080-1085
-
-
Bolinder, J.1
Ungerstedt, U.2
Arner, P.3
-
32
-
-
0031032280
-
Self-monitoring of blood glucose in type I diabetic patients: Comparison with continuous microdialysis measurements of glucose in subcutaneous adipose tissue during ordinary life conditions
-
Bolinder J, Hagstrom-Toft E, Ungerstedt U, Arner P: Self-monitoring of blood glucose in type I diabetic patients: comparison with continuous microdialysis measurements of glucose in subcutaneous adipose tissue during ordinary life conditions. Diabetes Care 1997;20:64-70.
-
(1997)
Diabetes Care
, vol.20
, pp. 64-70
-
-
Bolinder, J.1
Hagstrom-Toft, E.2
Ungerstedt, U.3
Arner, P.4
-
33
-
-
0028218970
-
Development of miniaturized glucose monitoring system by combining a needle-type glucose sensor with microdialysis sampling method
-
Hashiguchi Y, Sakakida M, Nishida K, Uemura T, Kajiwara K, Shichiri M: Development of miniaturized glucose monitoring system by combining a needle-type glucose sensor with microdialysis sampling method. Diabetes Care 1994;17:387-396.
-
(1994)
Diabetes Care
, vol.17
, pp. 387-396
-
-
Hashiguchi, Y.1
Sakakida, M.2
Nishida, K.3
Uemura, T.4
Kajiwara, K.5
Shichiri, M.6
-
34
-
-
0034491295
-
The MiniMed continuous glucose monitoring system
-
Mastrototaro JJ: The MiniMed continuous glucose monitoring system. Diabetes Technol Ther 2000;2(suppl 1):s13-s18.
-
(2000)
Diabetes Technol Ther
, vol.2
, Issue.SUPPL. 1
-
-
Mastrototaro, J.J.1
-
35
-
-
14844351847
-
The Diabetes Research in Children Network (DirecNet) Study Group: Accuracy of the modified Continuous Glucose Monitoring System (CGMS) sensor in an outpatient setting: results from a diabetes research in children network (DirecNet) study
-
Tansey MJ, Beck RW, Buckingham BA, Mauras N, Fiallo-Scharer R, Xing D, Killman C, Tamborlane WV, Ruedy KJ; The Diabetes Research in Children Network (DirecNet) Study Group: Accuracy of the modified Continuous Glucose Monitoring System (CGMS) sensor in an outpatient setting: results from a diabetes research in children network (DirecNet) study. Diabetes Technol Ther 2005;7:109-114.
-
(2005)
Diabetes Technol Ther
, vol.7
, pp. 109-114
-
-
Tansey, M.J.1
Beck, R.W.2
Buckingham, B.A.3
Mauras, N.4
Fiallo-Scharer, R.5
Xing, D.6
Killman, C.7
Tamborlane, W.V.8
Ruedy, K.J.9
-
36
-
-
3042781935
-
Glycemic patterns detected by continuous subcutaneous glucose sensing in children and adolescents with type 1 diabetes mellitus treated by multiple daily injections vs. continuous subcutaneous insulin infusion
-
Weintrob N, Schechter A, Benzaquen H, et al: Glycemic patterns detected by continuous subcutaneous glucose sensing in children and adolescents with type 1 diabetes mellitus treated by multiple daily injections vs. continuous subcutaneous insulin infusion. Arch Pediatr Adolesc Med 2004;158:677-684.
-
(2004)
Arch Pediatr Adolesc Med
, vol.158
, pp. 677-684
-
-
Weintrob, N.1
Schechter, A.2
Benzaquen, H.3
-
37
-
-
37549054745
-
Continuous Glucose Monitoring System in children with type 1 diabetes mellitus: A systematic review and meta-analysis
-
Golicki DT, Golicka D, Groele L, Pankowska E: Continuous Glucose Monitoring System in children with type 1 diabetes mellitus: a systematic review and meta-analysis. Diabetologia 2008;51:233-240.
-
(2008)
Diabetologia
, vol.51
, pp. 233-240
-
-
Golicki, D.T.1
Golicka, D.2
Groele, L.3
Pankowska, E.4
-
38
-
-
33746393341
-
Continuous glucose monitoring-guided insulin adjustment in children and adolescents on near-physiological insulin regimens: A randomized controlled trial
-
Yates K, Hasnat Milton A, Dear K, Ambler G: Continuous glucose monitoring-guided insulin adjustment in children and adolescents on near-physiological insulin regimens: a randomized controlled trial. Diabetes Care 2006;29:1512-1517.
-
(2006)
Diabetes Care
, vol.29
, pp. 1512-1517
-
-
Yates, K.1
Hasnat Milton, A.2
Dear, K.3
Ambler, G.4
-
39
-
-
33745249928
-
Continuous subcutaneous glucose monitoring in children with type 1 diabetes mellitus: A single-blind, randomized, controlled trial
-
Lagarde WH, Barrows FP, Davenport ML, Kang M, Guess HA, Calikoglu AS: Continuous subcutaneous glucose monitoring in children with type 1 diabetes mellitus: a single-blind, randomized, controlled trial. Pediatr Diabetes 2006;7:159-164.
-
(2006)
Pediatr Diabetes
, vol.7
, pp. 159-164
-
-
Lagarde, W.H.1
Barrows, F.P.2
Davenport, M.L.3
Kang, M.4
Guess, H.A.5
Calikoglu, A.S.6
-
40
-
-
33645455629
-
Results of an randomized controlled cross-over-trial on the effect of continuous glucose monitoring (CGMS) on glycemic control in children and adolescents with type 1 diabetes
-
Deiss D, Hartmann R, Schmidt J, Kordonouri O: Results of an randomized controlled cross-over-trial on the effect of continuous glucose monitoring (CGMS) on glycemic control in children and adolescents with type 1 diabetes. Exp Clin Endocrinol Diabetes 2006;114:63-67.
-
(2006)
Exp Clin Endocrinol Diabetes
, vol.114
, pp. 63-67
-
-
Deiss, D.1
Hartmann, R.2
Schmidt, J.3
Kordonouri, O.4
-
41
-
-
0038643466
-
Continuous subcutaneous glucose monitoring improved metabolic control in pediatric patients with type 1 diabetes: A controlled cross-over study
-
Ludvigsson J, Hanas R: Continuous subcutaneous glucose monitoring improved metabolic control in pediatric patients with type 1 diabetes: a controlled cross-over study. Pediatrics 2003;11:933-938.
-
(2003)
Pediatrics
, vol.11
, pp. 933-938
-
-
Ludvigsson, J.1
Hanas, R.2
-
42
-
-
0035142380
-
Continuous glucose monitoring in children with type 1 diabetes
-
Chase HP, Kim LM, Owen SL, et al: Continuous glucose monitoring in children with type 1 diabetes. Pediatrics 2001;107:222-226.
-
(2001)
Pediatrics
, vol.107
, pp. 222-226
-
-
Chase, H.P.1
Kim, L.M.2
Owen, S.L.3
-
43
-
-
34548321004
-
The Medtronic Minimed Gold continuous glucose monitoring system: An effective means to discover hypo- and hyperglycemia in children under 7 years of age
-
Gandrud LM, Xing D, Kollman C, Block JM, Kunselman B, Wilson DM, Buckingham BA: The Medtronic Minimed Gold continuous glucose monitoring system: an effective means to discover hypo- and hyperglycemia in children under 7 years of age. Diabetes Technol Ther 2007;9:307-316.
-
(2007)
Diabetes Technol Ther
, vol.9
, pp. 307-316
-
-
Gandrud, L.M.1
Xing, D.2
Kollman, C.3
Block, J.M.4
Kunselman, B.5
Wilson, D.M.6
Buckingham, B.A.7
-
44
-
-
34548297198
-
Continuous subcutaneous insulin infusion attenuated glycemic instability in preschool children with type 1 diabetes mellitus
-
Alemzadeh R, Palma-Sisto P, Holzum M, Parton E, Kicher J: Continuous subcutaneous insulin infusion attenuated glycemic instability in preschool children with type 1 diabetes mellitus. Diabetes Technol Ther 2007;9:339-347.
-
(2007)
Diabetes Technol Ther
, vol.9
, pp. 339-347
-
-
Alemzadeh, R.1
Palma-Sisto, P.2
Holzum, M.3
Parton, E.4
Kicher, J.5
-
45
-
-
33750616147
-
Unrecognised hypoglycaemia in children and adolescents with type 1 diabetes using the continuous glucose monitoring system: Prevalence and contributors
-
Wiltshire EJ, Newton K, McTavish L: Unrecognised hypoglycaemia in children and adolescents with type 1 diabetes using the continuous glucose monitoring system: prevalence and contributors. J Paediatr Child Health 2006;42:758-763.
-
(2006)
J Paediatr Child Health
, vol.42
, pp. 758-763
-
-
Wiltshire, E.J.1
Newton, K.2
McTavish, L.3
-
46
-
-
34249880433
-
Treatment with insulin glargine reduces asymptomatic hypoglycemia detected by continuous subcutaneous glucose monitoring in children and adolescents with type 1 diabetes
-
Deiss D, Kordonouri O, Hartmann R, Hopfenmüller W, Lüpke K, Danne T: Treatment with insulin glargine reduces asymptomatic hypoglycemia detected by continuous subcutaneous glucose monitoring in children and adolescents with type 1 diabetes. Pediatr Diabetes 2007;8:157-162.
-
(2007)
Pediatr Diabetes
, vol.8
, pp. 157-162
-
-
Deiss, D.1
Kordonouri, O.2
Hartmann, R.3
Hopfenmüller, W.4
Lüpke, K.5
Danne, T.6
-
47
-
-
34548426872
-
Hyperglycemia and externalizing behavior in children with type 1 diabetes
-
McDonnell CM, Northam EA, Donath SM, Werther GA, Cameron FJ: Hyperglycemia and externalizing behavior in children with type 1 diabetes. Diabetes Care 2007;30:2211-2215.
-
(2007)
Diabetes Care
, vol.30
, pp. 2211-2215
-
-
McDonnell, C.M.1
Northam, E.A.2
Donath, S.M.3
Werther, G.A.4
Cameron, F.J.5
-
48
-
-
33845483509
-
Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring
-
Deiss D, Bolinder J, Riveline JP, Battelino T, Bosi E, Tubiana-Rufi N, Kerr D, Phillip M: Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring. Diabetes Care 2006;29:2730-2732.
-
(2006)
Diabetes Care
, vol.29
, pp. 2730-2732
-
-
Deiss, D.1
Bolinder, J.2
Riveline, J.P.3
Battelino, T.4
Bosi, E.5
Tubiana-Rufi, N.6
Kerr, D.7
Phillip, M.8
-
49
-
-
36749003852
-
Real-time continuous glucose monitoring using GuardianRT: From research to clinical practice
-
Tubiana-Rufi N, Riveline JP, Dardari D: Real-time continuous glucose monitoring using GuardianRT: from research to clinical practice. Diabetes Metab 2007;33:415-420.
-
(2007)
Diabetes Metab
, vol.33
, pp. 415-420
-
-
Tubiana-Rufi, N.1
Riveline, J.P.2
Dardari, D.3
-
50
-
-
33845603166
-
A pilot trial in pediatrics with the sensor-augmented pump: Combining real-time continuous glucose monitoring with the insulin pump
-
Halvorson M, Carpenter S, Kaiserman K, Kaufman F: A pilot trial in pediatrics with the sensor-augmented pump: combining real-time continuous glucose monitoring with the insulin pump. J Pediatr 2007;150:103-105.
-
(2007)
J Pediatr
, vol.150
, pp. 103-105
-
-
Halvorson, M.1
Carpenter, S.2
Kaiserman, K.3
Kaufman, F.4
-
51
-
-
53549102819
-
First user experience with an integrated insulin pump and real-time continuous glucose monitoring system in pediatric and young adult patients with type 1 diabetes
-
Danne T, Liebl A, Reicherl A, Walte K, Bacher F, Röthig K, Lauterborn R, Kordonouri O: First user experience with an integrated insulin pump and real-time continuous glucose monitoring system in pediatric and young adult patients with type 1 diabetes. Pediatr Diabetes 2006;7(suppl 5):65.
-
(2006)
Pediatr Diabetes
, vol.7
, Issue.SUPPL. 5
, pp. 65
-
-
Danne, T.1
Liebl, A.2
Reicherl, A.3
Walte, K.4
Bacher, F.5
Röthig, K.6
Lauterborn, R.7
Kordonouri, O.8
-
52
-
-
33846111973
-
DirecNet Study Group: The accuracy of the FreeStyle Navigator continuous glucose monitoring system in children with type 1 diabetes
-
Wilson DM, Beck RW, Tamborlane WV, Dontchev MJ, Kollman C, Chase P, Fox LA, Ruedy KJ, Tsalikian E, Weinzimer SA; DirecNet Study Group: The accuracy of the FreeStyle Navigator continuous glucose monitoring system in children with type 1 diabetes. Diabetes Care 2007;30:59-64.
-
(2007)
Diabetes Care
, vol.30
, pp. 59-64
-
-
Wilson, D.M.1
Beck, R.W.2
Tamborlane, W.V.3
Dontchev, M.J.4
Kollman, C.5
Chase, P.6
Fox, L.A.7
Ruedy, K.J.8
Tsalikian, E.9
Weinzimer, S.A.10
-
53
-
-
34548660790
-
-
Diabetes Research in Children Network (DirecNet) Study Group, Buckingham B, Beck RW, Tamborlane WV, Xing D, Kollman C, Fiallo-Scharer R, Mauras N, Ruedy KJ, Tansey M, Weinzimer SA, Wysocki T: Continuous glucose monitoring in children with type 1 diabetes. J Pediatr 2007;151:388-393, 393.e1-e2.
-
Diabetes Research in Children Network (DirecNet) Study Group, Buckingham B, Beck RW, Tamborlane WV, Xing D, Kollman C, Fiallo-Scharer R, Mauras N, Ruedy KJ, Tansey M, Weinzimer SA, Wysocki T: Continuous glucose monitoring in children with type 1 diabetes. J Pediatr 2007;151:388-393, 393.e1-e2.
-
-
-
-
54
-
-
44449178472
-
Diabetes Research in Children Network (DirecNet) Study Group: FreeStyle navigator continuous glucose monitoring system use in children with type 1 diabetes using glargine-based multiple daily dose regimens: results of a pilot trial Diabetes Research in Children Network (DirecNet) Study Group
-
Weinzimer S, Xing D, Tansey M, Fiallo-Scharer R, Mauras N, Wysocki T, Beck R, Tamborlane W, Ruedy K; Diabetes Research in Children Network (DirecNet) Study Group: FreeStyle navigator continuous glucose monitoring system use in children with type 1 diabetes using glargine-based multiple daily dose regimens: results of a pilot trial Diabetes Research in Children Network (DirecNet) Study Group. Diabetes Care 2008;31:525-527.
-
(2008)
Diabetes Care
, vol.31
, pp. 525-527
-
-
Weinzimer, S.1
Xing, D.2
Tansey, M.3
Fiallo-Scharer, R.4
Mauras, N.5
Wysocki, T.6
Beck, R.7
Tamborlane, W.8
Ruedy, K.9
-
56
-
-
33749077158
-
Real-time continuous glucose monitoring in pediatric patients during and after cardiac surgery
-
Piper HG, Alexander JL, Shukla A, Pigula F, Costello JM, Laussen PC, Jaksic T, Agus MS: Real-time continuous glucose monitoring in pediatric patients during and after cardiac surgery. Pediatrics 2006;118:1176-1184.
-
(2006)
Pediatrics
, vol.118
, pp. 1176-1184
-
-
Piper, H.G.1
Alexander, J.L.2
Shukla, A.3
Pigula, F.4
Costello, J.M.5
Laussen, P.C.6
Jaksic, T.7
Agus, M.S.8
-
57
-
-
33748412631
-
Evaluation of factors affecting CGMS calibration
-
Diabetes Research In Children Network (Direcnet) Study Group
-
Diabetes Research In Children Network (Direcnet) Study Group, Buckingham BA, Kollman C, Beck R, Kalajian A, Fiallo-Scharer R, Tansey MJ, Fox LA, Wilson DM, Weinzimer SA, Ruedy KJ, Tamborlane WV: Evaluation of factors affecting CGMS calibration. Diabetes Technol Ther 2006;8:318-325.
-
(2006)
Diabetes Technol Ther
, vol.8
, pp. 318-325
-
-
Buckingham, B.A.1
Kollman, C.2
Beck, R.3
Kalajian, A.4
Fiallo-Scharer, R.5
Tansey, M.J.6
Fox, L.A.7
Wilson, D.M.8
Weinzimer, S.A.9
Ruedy, K.J.10
Tamborlane, W.V.11
-
58
-
-
33646692450
-
Psychological aspects of continuous glucose monitoring in pediatric type 1 diabetes
-
Diabetes Research in Children Network (DirecNet) Study Group
-
Diabetes Research in Children Network (DirecNet) Study Group: Psychological aspects of continuous glucose monitoring in pediatric type 1 diabetes. Pediatr Diabetes 2006;7:32-38.
-
(2006)
Pediatr Diabetes
, vol.7
, pp. 32-38
-
-
-
59
-
-
53549132034
-
-
Buckingham B, Halvorson M, Kunselman E, Kaufmann FR: Sensor augmented pump therapy in adolescents: results of the first treat-to-target study. Diabetes 2007;56(suppl 1):A 479.
-
Buckingham B, Halvorson M, Kunselman E, Kaufmann FR: Sensor augmented pump therapy in adolescents: results of the first treat-to-target study. Diabetes 2007;56(suppl 1):A 479.
-
-
-
-
60
-
-
0033970025
-
A subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration
-
Updike SJ, Shults MC, Gilligan BJ, Rhodes RK: A subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration. Diabetes Care 2000;23:208-214.
-
(2000)
Diabetes Care
, vol.23
, pp. 208-214
-
-
Updike, S.J.1
Shults, M.C.2
Gilligan, B.J.3
Rhodes, R.K.4
-
61
-
-
0036902299
-
Implantable closed-loop glucosesensing and insulin delivery: The future for insulin pump therapy
-
Renard E: Implantable closed-loop glucosesensing and insulin delivery: the future for insulin pump therapy. Curr Opin Pharmacol 2002;2:708-716.
-
(2002)
Curr Opin Pharmacol
, vol.2
, pp. 708-716
-
-
Renard, E.1
-
63
-
-
38949150087
-
Detection of a meal using continuous glucose monitoring (CGM): Implications for an artificial beta-cell
-
Dassau E, Bequette BW, Buckingham BA, Doyle FJ: Detection of a meal using continuous glucose monitoring (CGM): implications for an artificial beta-cell. Diabetes Care 2008;31:295-300.
-
(2008)
Diabetes Care
, vol.31
, pp. 295-300
-
-
Dassau, E.1
Bequette, B.W.2
Buckingham, B.A.3
Doyle, F.J.4
-
64
-
-
18144421498
-
Continuous glucose monitoring: Roadmap for 21st century diabetes therapy
-
Klonoff DC: Continuous glucose monitoring: roadmap for 21st century diabetes therapy. Diabetes Care 2005;28:1231-1239.
-
(2005)
Diabetes Care
, vol.28
, pp. 1231-1239
-
-
Klonoff, D.C.1
|