메뉴 건너뛰기




Volumn , Issue , 2008, Pages 5650-5656

Improved chest wall imaging through combined complex trajectories in dedicated dual modality SPECT-CT breast molecular imaging

Author keywords

[No Author keywords available]

Indexed keywords

3D POSITIONING; BREAST IMAGING SYSTEM; CHEST WALL; COMPLEX TRAJECTORIES; CONE BEAM; CT SYSTEM; DATA SETS; DUAL MODALITY; DUAL-MODALITY SYSTEMS; INTEGRATED IMAGING SYSTEMS; LIMITED-ANGLE TOMOGRAPHY; MOLECULAR IMAGING; OBSERVER STUDIES; PATIENT BED; PATIENT POSITIONING; RECONSTRUCTED IMAGE; SPECT SYSTEM; TASK-BASED;

EID: 67649237336     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2008.4774525     Document Type: Conference Paper
Times cited : (5)

References (19)
  • 1
    • 23744501752 scopus 로고    scopus 로고
    • Evaluation of fully 3-D emission mammotomography with a compact cadmium zinc telluride detector
    • DOI 10.1109/TMI.2005.852501, Molecular Imaging
    • C. N. Brzymialkiewicz, M. P. Tornai, R. L. McKinley, and J. E. Bowsher, "Evaluation of fully 3D emission mammotomography with a compact cadmium zinc telluride detector," IEEE Trans. Med. Imag, vol.24, pp. 868-877, 2005. (Pubitemid 41118464)
    • (2005) IEEE Transactions on Medical Imaging , vol.24 , Issue.7 , pp. 868-877
    • Brzymialkiewicz, C.N.1    Tornai, M.P.2    McKinley, R.L.3    Bowsher, J.E.4
  • 3
    • 33745373479 scopus 로고    scopus 로고
    • Preliminary investigation of dose for a dedicated mammotomography system
    • R. L. McKinley and M. P. Tornai, "Preliminary investigation of dose for a dedicated mammotomography system," 2006 Proc SPIE: Phys Med Imag, vol.6142, pp. 60-70, 11-17 Feb. 2006 2006.
    • (2006) 2006 Proc SPIE: Phys Med Imag , vol.6142 , Issue.200 , pp. 60-70
    • McKinley, R.L.1    Tornai, M.P.2
  • 4
    • 67649137477 scopus 로고    scopus 로고
    • Initial design considerations of a dedicated hybrid mammotomograph for fully 3D x-ray CT and high resolution PET using object magnification
    • Toronto, ON
    • M. P. Tornai, Y. C. Tai, and R. L. McKinley, "Initial design considerations of a dedicated hybrid mammotomograph for fully 3D x-ray CT and high resolution PET using object magnification," in Society of Nuclear Medicine Annual Meeting, Toronto, ON, 2005.
    • (2005) Society of Nuclear Medicine Annual Meeting
    • Tornai, M.P.1    Tai, Y.C.2    McKinley, R.L.3
  • 7
    • 48149085614 scopus 로고    scopus 로고
    • Investigating novel patient bed designs for use in a hybrid dual modality dedicated 3D breast imaging system
    • D. J. Crotty, P. Madhav, R. L. McKinley, and M. P. Tornai, "Investigating novel patient bed designs for use in a hybrid dual modality dedicated 3D breast imaging system," 2007 SPIE Med Imag Conf vol.6150,2007.
    • (2007) 2007 SPIE Med Imag Conf , vol.6150
    • Crotty, D.J.1    Madhav, P.2    McKinley, R.L.3    Tornai, M.P.4
  • 10
    • 33846611354 scopus 로고    scopus 로고
    • Towards patient imaging with dedicated emission mammotomography
    • DOI 10.1109/NSSMIC.2005.1596607, 1596607, 2005 IEEE Nuclear Science Symposium Conference Record -Nuclear Science Symposium and Medical Imaging Conference
    • C. N. Brzymialkiewicz, R. L. McKinley, and M. P. Tornai, "Towards patient imaging with dedicated emission mammotomography," 2005 IEEE Nucl Sci Symp & Med Imag Conf vol.3, pp. 1519-1523, 23-29 Oct. 2005 2005. (Pubitemid 46172031)
    • (2005) IEEE Nuclear Science Symposium Conference Record , vol.3 , pp. 1519-1523
    • Brzymialkiewicz, C.N.1    McKinley, R.L.2    Tornai, M.P.3
  • 12
    • 0025221610 scopus 로고
    • Computed tomography scanning with simultaneous patient translation
    • C. R. Crawford and K. F. King, "Computed tomography scanning with simultaneous patient translation," Medical Physics, vol.17, pp. 967-982, 1990.
    • (1990) Medical Physics , vol.17 , pp. 967-982
    • Crawford, C.R.1    King, K.F.2
  • 13
    • 33748948707 scopus 로고    scopus 로고
    • Performance of dedicated emission mammotomography for various breast shapes and sizes
    • DOI 10.1088/0031-9155/51/19/021, PII S0031915506237126, 021
    • C. N. Brzymialkiewicz, M. P. Tornai, R. L. McKinley, S. J. Cutler, and J. E. Bowsher, "Performance for dedicated emission mammotomography for various breast shapes and sizes," Phys Med Biol, vol.51, pp. 5051-5064, 2006. (Pubitemid 44429860)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.19 , pp. 5051-5064
    • Brzymialkiewicz, C.N.1    Tornai, M.P.2    McKinley, R.L.3    Cutler, S.J.4    Bowsher, J.E.5
  • 14
    • 23844478988 scopus 로고    scopus 로고
    • 3D data acquisition sampling strategies for dedicated emission mammotomography for various breast sizes
    • M2-269, 2004 IEEE Nuclear Science Symposium Conference Record
    • C. N. Brzymialkiewicz, M. P. Tornai, R. L. McKinley, and J. E. Bowsher, "3D data acquisition sampling strategies for dedicated emission mammotomography for various breast sizes," 2005 IEEE Nucl Sci Symp & Med Imag Conf vol.4, pp. 2596-2600,16-22 Oct. 2004 2004. (Pubitemid 41148102)
    • (2004) IEEE Nuclear Science Symposium Conference Record , vol.4 , pp. 2596-2600
    • Brzymialkiewicz, C.N.1    Tornai, M.P.2    McKinley, R.L.3    Cutler, S.J.4    Bowsher, J.E.5
  • 15
    • 33846585632 scopus 로고    scopus 로고
    • Investigating the effects of energy resolution in dedicated emission mammotomography
    • DOI 10.1109/NSSMIC.2005.1596856, 1596856, 2005 IEEE Nuclear Science Symposium Conference Record -Nuclear Science Symposium and Medical Imaging Conference
    • S. J. Cutler, C. N. Brzymialkiewicz, and M. P. Tornai, "Investigating the effects of energy resolution in dedicated emission mammotomography," 2005 IEEE Nucl Sci Symp & Med Imag Conf vol.5, pp. 2537-2541,23-29 Oct. 2005 2005. (Pubitemid 46172261)
    • (2005) IEEE Nuclear Science Symposium Conference Record , vol.5 , pp. 2537-2541
    • Cutler, S.J.1    Brzymialkiewicz, C.N.2    Tornai, M.P.3
  • 16
    • 23844549425 scopus 로고    scopus 로고
    • Comparison of scintimammography and dedicated emission mammotomography
    • M3-6, 2004 IEEE Nuclear Science Symposium Conference Record
    • M. P. Tornai, C. N. Brzymialkiewicz, and R. L. McKinley, "Comparison of scintimammography and dedicated emission mammotomography," in 2004 IEEE Nucl. Sci. Symposium & Med. Imaging Conference, Rome, Italy, 2004, pp. 2818-2822. (Pubitemid 41147853)
    • (2004) IEEE Nuclear Science Symposium Conference Record , vol.5 , pp. 2818-2822
    • Tornai, M.P.1    Brzymialkiewicz, C.N.2    Cutler, S.J.3    Madhav, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.