메뉴 건너뛰기




Volumn 6, Issue , 2007, Pages 4044-4050

Comparison of reduced angle and fully 3D acquisition sequencing and trajectories for dual-modality mammotomography

Author keywords

[No Author keywords available]

Indexed keywords

3D-ACQUISITION; ANTHROPOMORPHIC BREAST PHANTOM; BREAST CANCER IMAGING; BREAST IMAGING; CENTER OF ROTATION; CHEST-WALL; CONE BEAMS; CONE-BEAM CT; CT IMAGING; DUAL-MODALITY; FIELD OF VIEWS; IMAGE DEGRADATIONS; IMAGING PROTOCOLS; ITERATIVE RECONSTRUCTION ALGORITHMS; MAMMOTOMOGRAPHY; NUCLEAR SCIENCES; PROJECTION ANGLES; SPECT SYSTEM; SPECT-CT;

EID: 48149099262     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2007.4437016     Document Type: Conference Paper
Times cited : (6)

References (18)
  • 1
  • 2
    • 48149085614 scopus 로고    scopus 로고
    • Investigating novel patient bed designs for use in a hybrid dual modality dedicated 3D breast imaging system
    • D. J. Crotty, P. Madhav, R. L. McKinley, and M. P. Tornai, "Investigating novel patient bed designs for use in a hybrid dual modality dedicated 3D breast imaging system," 2007 SPIE Med Imag Conf, vol. 6150, 2007.
    • (2007) 2007 SPIE Med Imag Conf , vol.6150
    • Crotty, D.J.1    Madhav, P.2    McKinley, R.L.3    Tornai, M.P.4
  • 3
    • 33745377441 scopus 로고    scopus 로고
    • Investigation of emission contamination in the transmission image of a dual modality computed mammotomography system
    • D. J. Crotty, C. N. Brzymialkiewicz, R. L. McKinley, and M. P. Tornai, "Investigation of emission contamination in the transmission image of a dual modality computed mammotomography system," 2006 Proc SPIE: Phys Med Imag, vol. 6142, pp. 664-674, 2006.
    • (2006) 2006 Proc SPIE: Phys Med Imag , vol.6142 , pp. 664-674
    • Crotty, D.J.1    Brzymialkiewicz, C.N.2    McKinley, R.L.3    Tornai, M.P.4
  • 5
    • 0141928682 scopus 로고    scopus 로고
    • Digital x-ray tomosynthesis: Current state of the art and clinical potential
    • J. T. Dobbins, 3rd and D. J. Godfrey, "Digital x-ray tomosynthesis: current state of the art and clinical potential," Phys Med Biol, vol. 48, pp. R65-106, 2003.
    • (2003) Phys Med Biol , vol.48
    • Dobbins 3rd, J.T.1    Godfrey, D.J.2
  • 6
    • 34548225376 scopus 로고    scopus 로고
    • Digital breast tomosynthesis: Initial experience in 98 women with abnormal digital screening mammography
    • S. P. Poplack, T. D. Tosteson, C. A. Kogel, and H. M. Nagy, "Digital breast tomosynthesis: initial experience in 98 women with abnormal digital screening mammography," AJR Am J Roentgenol, vol. 189, pp. 616-623, 2007.
    • (2007) AJR Am J Roentgenol , vol.189 , pp. 616-623
    • Poplack, S.P.1    Tosteson, T.D.2    Kogel, C.A.3    Nagy, H.M.4
  • 9
    • 33749404804 scopus 로고    scopus 로고
    • A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis
    • Y. Zhang, H. P. Chan, B. Sahiner, J. Wei, M. M. Goodsitt, L. M. Hadjiiski, J. Ge, and C. Zhou, "A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis," Med Phys. vol. 33. pp. 3781-3795, 2006.
    • (2006) Med Phys , vol.33 , pp. 3781-3795
    • Zhang, Y.1    Chan, H.P.2    Sahiner, B.3    Wei, J.4    Goodsitt, M.M.5    Hadjiiski, L.M.6    Ge, J.7    Zhou, C.8
  • 10
    • 23744501752 scopus 로고    scopus 로고
    • Evaluation of fully 3D emission mammotomography with a compact cadmium zinc telluride detector
    • C. N. Brzymialkiewicz, M. P. Tornai, R. L. McKinley, and J. E. Bowsher, "Evaluation of fully 3D emission mammotomography with a compact cadmium zinc telluride detector," IEEE Trans. Med. Imag., vol. 24, pp. 868-877, 2005.
    • (2005) IEEE Trans. Med. Imag , vol.24 , pp. 868-877
    • Brzymialkiewicz, C.N.1    Tornai, M.P.2    McKinley, R.L.3    Bowsher, J.E.4
  • 11
    • 33748948707 scopus 로고    scopus 로고
    • Performance of dedicated emission mammotomography for various breast shapes and sizes
    • C. N. Brzymialkiewicz, M. P. Tornai, R. L. McKinley, S. J. Cutler, and J. E. Bowsher, "Performance of dedicated emission mammotomography for various breast shapes and sizes," Phys Med Biol, vol. 51, pp. 5051-5064, 2006.
    • (2006) Phys Med Biol , vol.51 , pp. 5051-5064
    • Brzymialkiewicz, C.N.1    Tornai, M.P.2    McKinley, R.L.3    Cutler, S.J.4    Bowsher, J.E.5
  • 13
    • 23844455030 scopus 로고    scopus 로고
    • Investigation of cone-beam acquisitions implemented using a novel dedicated mammotomography system with unique arbitrary orbit capability
    • R. L. McKinley, C. N. Brzymialkiewicz, P. Madhav, and M. P. Tornai, "Investigation of cone-beam acquisitions implemented using a novel dedicated mammotomography system with unique arbitrary orbit capability," 2005 Proc SPIE: Phys Med Imag, vol. 5745. pp. 609-617, 2005.
    • (2005) 2005 Proc SPIE: Phys Med Imag , vol.5745 , pp. 609-617
    • McKinley, R.L.1    Brzymialkiewicz, C.N.2    Madhav, P.3    Tornai, M.P.4
  • 14
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • H. M. Hudson and R. S. Larkin, "Accelerated image reconstruction using ordered subsets of projection data," IEEE Trans. Med. Imag., vol. 13, pp. 601-609, 1994.
    • (1994) IEEE Trans. Med. Imag , vol.13 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 15
    • 34247181672 scopus 로고    scopus 로고
    • Analysis of a novel offset cone-beam computed mammotomography system geometry for accomodating various breast sizes
    • R. L. McKinley, M. P. Tornai, C. Brzymialkiewicz, P. Madhav, E. Samei, and J. E. Bowsher, "Analysis of a novel offset cone-beam computed mammotomography system geometry for accomodating various breast sizes," Physica Medica, vol. 21, pp. 48-55, 2006.
    • (2006) Physica Medica , vol.21 , pp. 48-55
    • McKinley, R.L.1    Tornai, M.P.2    Brzymialkiewicz, C.3    Madhav, P.4    Samei, E.5    Bowsher, J.E.6
  • 16
    • 0345103297 scopus 로고    scopus 로고
    • Ordered subsets algorithms for transmission tomography
    • H. Erdogan and J. A. Fessler, "Ordered subsets algorithms for transmission tomography," Phys Med Biol, vol. 44, pp. 2835-2851, 1999.
    • (1999) Phys Med Biol , vol.44 , pp. 2835-2851
    • Erdogan, H.1    Fessler, J.A.2
  • 17
    • 0242409499 scopus 로고    scopus 로고
    • AMIDE: A free software tool for multimodality medical image analysis
    • A. M. Loening and S. S. Gambhir, "AMIDE: a free software tool for multimodality medical image analysis," Mol Imaging, vol. 2, pp. 131-137, 2003.
    • (2003) Mol Imaging , vol.2 , pp. 131-137
    • Loening, A.M.1    Gambhir, S.S.2
  • 18
    • 48149089517 scopus 로고    scopus 로고
    • D. Stout, Multimodality image display and analysis using AMIDE, J Nucl Med, 48, p. (Supplement 2) 205P, 2007.
    • D. Stout, "Multimodality image display and analysis using AMIDE," J Nucl Med, vol. 48, p. (Supplement 2) 205P, 2007.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.