메뉴 건너뛰기




Volumn 5, Issue , 2005, Pages 2537-2541

Investigating the effects of energy resolution in dedicated emission mammotomography

Author keywords

[No Author keywords available]

Indexed keywords

3D LESION IMAGING; ENERGY RESOLUTION; PHANTOMS; SINGLE PHOTON EMISSION MAMMOTOMOGRAPHY;

EID: 33846585632     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2005.1596856     Document Type: Conference Paper
Times cited : (6)

References (12)
  • 1
    • 0001800886 scopus 로고    scopus 로고
    • Dedicated breast imaging with an ASET: Application specific emission tomograph
    • M. P. Tornai et al., "Dedicated breast imaging with an ASET: Application specific emission tomograph," J. Nucl. Med., vol. 42, no. 5, p.97P, 2001.
    • (2001) J. Nucl. Med , vol.42 , Issue.5
    • Tornai, M.P.1
  • 2
    • 0037706081 scopus 로고    scopus 로고
    • Implementation and initial characterization of acquisition orbits with a dedicated emission mammotomograph
    • C. N. Archer, M. P. Tornai, J. E. Bowsher, S. D. Metzler, B. C. Pieper, and R. J. Jaszczak, "Implementation and initial characterization of acquisition orbits with a dedicated emission mammotomograph," IEEE Trans. Nucl. Sci., vol. 50, pp. 413-420, 2003.
    • (2003) IEEE Trans. Nucl. Sci , vol.50 , pp. 413-420
    • Archer, C.N.1    Tornai, M.P.2    Bowsher, J.E.3    Metzler, S.D.4    Pieper, B.C.5    Jaszczak, R.J.6
  • 4
    • 23744501752 scopus 로고    scopus 로고
    • Evaluation of Fully 3D Emission Mammotomography with a Compact Cadmium Zinc Telluride Detector
    • C. N. Brzymialkiewicz, M. P. Tornai, R. L. McKinley, and J. E. Bowsher, "Evaluation of Fully 3D Emission Mammotomography with a Compact Cadmium Zinc Telluride Detector," IEEE Trans. Med. Imag., vol. 24, pp. 868-877,2005.
    • (2005) IEEE Trans. Med. Imag , vol.24 , pp. 868-877
    • Brzymialkiewicz, C.N.1    Tornai, M.P.2    McKinley, R.L.3    Bowsher, J.E.4
  • 6
    • 0021924201 scopus 로고
    • Effect of resolution improvement on required count density in ECT imaging: A computer simulation
    • G Muehllehner. Effect of resolution improvement on required count density in ECT imaging: a computer simulation.Phys. Med. Biol. 30:163-173. 1985.
    • (1985) Phys. Med. Biol , vol.30 , pp. 163-173
    • Muehllehner, G.1
  • 7
    • 0031599142 scopus 로고    scopus 로고
    • Mersenne Twister: A 623-Dimensionally Equidistributed Uniform Pseudo-Random Number Generator
    • January
    • M. Matsumoto and T. Nishimura, "Mersenne Twister: A 623-Dimensionally Equidistributed Uniform Pseudo-Random Number Generator", ACM Transactions on Modeling and Computer Simulation, Vol. 8, No. 1, January 1998, pp 3-30.
    • (1998) ACM Transactions on Modeling and Computer Simulation , vol.8 , Issue.1 , pp. 3-30
    • Matsumoto, M.1    Nishimura, T.2
  • 8
    • 33846579657 scopus 로고    scopus 로고
    • http://www-personal.engin.umich.edu/~wagnerr/MersenneTwister.html
  • 9
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • H. M. Hudson and R. S. Larkin "Accelerated image reconstruction using ordered subsets of projection data," IEEE Trans. Med. Imag, vol 13, pp. 601-609, 1994.
    • (1994) IEEE Trans. Med. Imag , vol.13 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 10
    • 0024910866 scopus 로고
    • Resampling estimates of precision in emission tomography
    • D.R. Haynor and S.D. Woods. Resampling estimates of precision in emission tomography. IEEE Trans. Med. Imag., 8(4):337-343, 1989.
    • (1989) IEEE Trans. Med. Imag , vol.8 , Issue.4 , pp. 337-343
    • Haynor, D.R.1    Woods, S.D.2
  • 11
    • 0037150011 scopus 로고    scopus 로고
    • A non-parametric bootstrap approach for analyzing the statistical properties of SPECT and PET images
    • I. Buvat. A non-parametric bootstrap approach for analyzing the statistical properties of SPECT and PET images. Phys. Med. Biol., 47:1761-1775, 2002.
    • (2002) Phys. Med. Biol , vol.47 , pp. 1761-1775
    • Buvat, I.1
  • 12
    • 0036816162 scopus 로고    scopus 로고
    • Estimation of image noise in PET using the bootstrap method
    • M. Dahlbom. Estimation of image noise in PET using the bootstrap method. IEEE Trans. Nucl. Sci., 49(5):2062-2066, 2002.
    • (2002) IEEE Trans. Nucl. Sci , vol.49 , Issue.5 , pp. 2062-2066
    • Dahlbom, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.