메뉴 건너뛰기




Volumn 24, Issue 1, 2009, Pages 88-95

Combined influence of implant diameter and alveolar ridge width on crestal bone stress: A quantitative approach

Author keywords

Crestal bone stress; Finite element simulation; Implant diameter; Key words alveolar ridge width; Stress singularity; Structural rigidity

Indexed keywords

ARTICLE; BIOLOGICAL MODEL; BIOMECHANICS; COMPUTER SIMULATION; ELASTICITY; FINITE ELEMENT ANALYSIS; HUMAN; JAW; MECHANICAL STRESS; PATHOLOGY; PATHOPHYSIOLOGY; SURFACE PROPERTY; TOOTH IMPLANTATION; TOOTH PROSTHESIS; WEIGHT BEARING;

EID: 67649233037     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (15)

References (39)
  • 1
    • 0033212422 scopus 로고    scopus 로고
    • Hansson S.The implant neck: Smooth or provided with retention elements
    • Hansson S.The implant neck: Smooth or provided with retention elements. A biomechanical approach. Clin Oral Implants Res 1999;10:394-405.
    • (1999) A Biomechanical Approach. Clin Oral Implants Res , vol.10 , pp. 394-405
  • 2
    • 0041418181 scopus 로고    scopus 로고
    • Miyakawa 0, Kusakari H. Influence of implant design and bone quality on stress/strain distribution in bone around implants: A 3-dimensional finite element analysis
    • Tada S, Stegaroiu R, Kitamura E, Miyakawa 0, Kusakari H. Influence of implant design and bone quality on stress/strain distribution in bone around implants: A 3-dimensional finite element analysis. Int J Oral Maxillofac Implants 2003;18:357-368.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 357-368
    • Tada, S.1    Stegaroiu, R.2    Kitamura, E.3
  • 3
    • 26944455656 scopus 로고    scopus 로고
    • Comparative evaluation of implant designs: Influence of diameter, length, and taper on strains in the alveolar crest. A three-dimensional finite-element analysis
    • Petrie CS, Williams JL. Comparative evaluation of implant designs: Influence of diameter, length, and taper on strains in the alveolar crest. A three-dimensional finite-element analysis. Clin Oral Implants Res 2005;16:486-494.
    • (2005) Clin Oral Implants Res , vol.16 , pp. 486-494
    • Petrie, C.S.1    Williams, J.L.2
  • 4
    • 0032198792 scopus 로고    scopus 로고
    • Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog
    • Barbier L,Vander Sloten J, Krzesinski G, Schepers E,Van der Perre G. Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog. J Oral Rehabil 1998;25:847-858.
    • (1998) J Oral Rehabil , vol.25 , pp. 847-858
    • Barbier, L.1    Vander Sloten, J.2    Krzesinski, G.3    Schepers, E.4    Van Der Perre, G.5
  • 5
    • 4644291445 scopus 로고    scopus 로고
    • Biomechanical aspects of marginal bone resorption around osseointegrated implants: Considerations based on a three-dimensional finite element analysis
    • Kitamura E, Stegaroiu R, Nomura S, Miyakawa O. Biomechanical aspects of marginal bone resorption around osseointegrated implants: Considerations based on a three-dimensional finite element analysis. Clin Oral Implants Res 2004;15:401-412.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 401-412
    • Kitamura, E.1    Stegaroiu, R.2    Nomura, S.3    Miyakawa, O.4
  • 6
    • 16344386568 scopus 로고    scopus 로고
    • Influence of marginal bone resorption on stress around an implant. A three-dimensional finite element analysis
    • Kitamura E, Stegaroiu R, Nomura S, Miyakawa 0. Influence of marginal bone resorption on stress around an implant: A three-dimensional finite element analysis. j Oral Rehabil 2005;32:279-286.
    • (2005) J Oral Rehabil , vol.32 , pp. 279-286
    • Kitamura, E.1    Stegaroiu, R.2    Nomura, S.3    Miyakawa, O.4
  • 7
    • 33645078906 scopus 로고    scopus 로고
    • Analysis of bone-implant interaction phenomena by using a numerical approach
    • Natali AN, Pavan PG, Ruggero AL. Analysis of bone-implant interaction phenomena by using a numerical approach. Clin Oral Implants Res 2006;17:67-74.
    • (2006) Clin Oral Implants Res , vol.17 , pp. 67-74
    • Natali, A.N.1    Pavan, P.G.2    Ruggero, A.L.3
  • 8
    • 0031309247 scopus 로고    scopus 로고
    • Influence of bone quality on stress distribution for endosseous implants
    • Holmes DC, Loftus JT. Influence of bone quality on stress distribution for endosseous implants. J Oral Implantol 1997;23:104-111.
    • (1997) J Oral Implantol , vol.23 , pp. 104-111
    • Holmes, D.C.1    Loftus, J.T.2
  • 9
    • 23944475039 scopus 로고    scopus 로고
    • Influence of cortical bone quality on stress distribution in bone around dental implant
    • KitagawaT,TanimotoY, Nemoto K,Aida M. Influence of cortical bone quality on stress distribution in bone around dental implant. Dent Mater j 2005;24:219-224.
    • (2005) Dent Mater J , vol.24 , pp. 219-224
    • Kitagawattanimotoy1    Nemoto Kaida, M.2
  • 10
    • 14844290222 scopus 로고    scopus 로고
    • Three- dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown
    • Sevimay M.Turhan F, Kilicarslan MA, Eskitascioglu G.Three- dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown. J Prosthet Dent 2005;93:227-234.
    • (2005) J Prosthet Dent , vol.93 , pp. 227-234
    • Sevimay, M.1    Turhan, F.2    Kilicarslan, M.A.3    Eskitascioglu, G.4
  • 11
    • 1842840921 scopus 로고    scopus 로고
    • Update of bone physiology and Wolff's Law for clinicians
    • Frost HM.A 2003 update of bone physiology and Wolff's Law for clinicians. Angle Orthod 2004;74:3-15.
    • (2003) Angle Orthod , vol.2004 , Issue.74 , pp. 3-15
    • Frost, HM.A.1
  • 12
    • 0022726532 scopus 로고
    • The long- term efficacy of currently used dental implants: A review and proposed criteria for success
    • Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long- term efficacy of currently used dental implants: A review and proposed criteria for success. Int J Oral Maxillofac Implants 1986;1:11-25.
    • (1986) Int J Oral Maxillofac Implants , vol.1 , pp. 11-25
    • Albrektsson, T.1    Zarb, G.2    Worthington, P.3    Eriksson, A.R.4
  • 13
    • 85016033318 scopus 로고
    • Mechanical loading of BrSnemark implants affects interfacial bone modeling and remodeling
    • Hoshaw SJ, Brunski JB, Cochran GVB. Mechanical loading of BrSnemark implants affects interfacial bone modeling and remodeling. Int J Oral Maxillofac Implants 1994;9:345-360.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 345-360
    • Hoshaw, S.J.1    Brunski, J.B.2    Cochran, G.V.B.3
  • 14
    • 0028083161 scopus 로고
    • Location of implants in the interforaminal region of the mandible and the consequences for the design of the superstructure
    • Meijer HJ, Starmans FJ, Steen WH, Bosman F. Location of implants in the interforaminal region of the mandible and the consequences for the design of the superstructure. J Oral Rehabil 1994;21:47-56.
    • (1994) J Oral Rehabil , vol.21 , pp. 47-56
    • Meijer, H.J.1    Starmans, F.J.2    Steen, W.H.3    Bosman, F.4
  • 15
    • 20744449333 scopus 로고    scopus 로고
    • Crestal bone changes around titanium implants. Part I: A retrospective radiographic evaluation in humans comparing two non-submerged implant designs with different machined collar lengths
    • Hanggi MP, Hanggi DC, Schoolfield JD, Meyer J, Cochran DL, Hermann JS. Crestal bone changes around titanium implants. Part I: A retrospective radiographic evaluation in humans comparing two non-submerged implant designs with different machined collar lengths. J Periodontol 2005;76:791-802.
    • (2005) J Periodontol , vol.76 , pp. 791-802
    • Hanggi, M.P.1    Hanggi, D.C.2    Schoolfield, J.D.3    Meyer, J.4    Cochran, D.L.5    Hermann, J.S.6
  • 16
    • 0031986671 scopus 로고    scopus 로고
    • Evaluating parameters of osseointegrated dental implants using finite element analysis: A two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction
    • Holmgren EP,Seckinger RJ, Kilgren LM, Mante F. Evaluating parameters of osseointegrated dental implants using finite element analysis: A two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction. J Oral Implantol 1998;24:80-88.
    • (1998) J Oral Implantol , vol.24 , pp. 80-88
    • Holmgren Epseckinger, R.J.1    Kilgren, L.M.2    Mante, F.3
  • 17
    • 0025581284 scopus 로고
    • Two-dimensional FEM analysis of hydroxyapatite implants: Diameter effects on stress distribution
    • Matsushita Y,Kitoh M,Mizuta K,lkeda H,SuetsuguT.Two- dimensional FEM analysis of hydroxyapatite implants: Diameter effects on stress distribution. J Oral Implantol 1990;16:6-11.
    • (1990) J Oral Implantol , vol.16 , pp. 6-11
    • Matsushita, Y.1    Kitoh, M.2    Mizuta, K.3    Ikeda, H.4    Suetsugu, T.5
  • 18
    • 0026926786 scopus 로고
    • The effect of abutment angulation on stress transfer for an implant
    • Clelland NL, Gilat A.The effect of abutment angulation on stress transfer for an implant. J Prosthodont 1992;1:24-28.
    • (1992) J Prosthodont , vol.1 , pp. 24-28
    • Clelland, N.L.1    Gilat, A.2
  • 19
    • 33646232732 scopus 로고    scopus 로고
    • Influence of implant abutment type on stress distribution in bone under various loading conditions using finite element analysis
    • Chun HJ, Shin HS, Han CH, Lee SH. Influence of implant abutment type on stress distribution in bone under various loading conditions using finite element analysis. Int J Oral Maxillofac Implants 2006;21:195-202.
    • (2006) Int J Oral Maxillofac Implants , vol.21 , pp. 195-202
    • Chun, H.J.1    Shin, H.S.2    Ch, H.3    Lee, S.H.4
  • 20
    • 19044381224 scopus 로고    scopus 로고
    • Evaluation of design parameters of osseointegrated dental implants using finite element analysis
    • Chun HJ, Cheong SY, Han JH, et al. Evaluation of design parameters of osseointegrated dental implants using finite element analysis. J Oral Rehabil 2002;29:565-574.
    • (2002) J Oral Rehabil , vol.29 , pp. 565-574
    • Chun, H.J.1    Cheong, S.Y.2    Han, J.H.3    Al, E.4
  • 21
    • 0042625004 scopus 로고    scopus 로고
    • The implant thread as a retention element in cortical bone: The effect of thread size and thread profile: A finite element study
    • Hansson S,Werke M.The implant thread as a retention element in cortical bone: The effect of thread size and thread profile: A finite element study. J Biomech 2003;36:1247-1258.
    • (2003) J Biomech , vol.36 , pp. 1247-1258
    • Hansson, S.1    Werke, M.2
  • 22
    • 0035375058 scopus 로고    scopus 로고
    • Bone reactions adjacent to titanium implants with different surface characteristics subjected to static load. A study in the dog (II)
    • Gotfredsen K, Berglundh T, Lindhe J. Bone reactions adjacent to titanium implants with different surface characteristics subjected to static load. A study in the dog (II). Clin Oral Implants Res 2001;12:196-201. (Pubitemid 33723220)
    • (2001) Clinical Oral Implants Research , vol.12 , Issue.3 , pp. 196-201
    • Gotfredsen, K.1    Berglundh, T.2    Lindhe, J.3
  • 23
    • 13744251734 scopus 로고    scopus 로고
    • A 6-year prospective study of 620 stress-diversion surface (SDS) dental implants
    • O'Brien GR, Gonshor A, Balfour A. A 6-year prospective study of 620 stress-diversion surface (SDS) dental implants. J Oral Implantol 2004;30:350-357.
    • (2004) J Oral Implantol , vol.30 , pp. 350-357
    • O'Brien, G.R.1    Gonshor, A.2    Balfour, A.3
  • 24
    • 9944241763 scopus 로고    scopus 로고
    • Evaluation of load transfer characteristics of five different implants in compact bone at different load levels by finite elements analysis
    • Bozkaya D, Muftu S, Muftu A. Evaluation of load transfer characteristics of five different implants in compact bone at different load levels by finite elements analysis. J Prosthet Dent 2004;92:523-530.
    • (2004) J Prosthet Dent , vol.92 , pp. 523-530
    • Bozkaya, D.1    Muftu, S.2    Muftu, A.3
  • 25
    • 49849127971 scopus 로고
    • Remarks on the singularity of elastic solutions near corners
    • Kalandiia Al. Remarks on the singularity of elastic solutions near corners. J Appl Math Mech 1969;33:127-131.
    • (1969) J Appl Math Mech , vol.33 , pp. 127-131
    • Al, K.1
  • 26
    • 0001701945 scopus 로고
    • Mesh-dependence and stress singularity in finite element analysis of creep crack growth by continuum damage mechanics approach
    • Liu Y, Murakami S, Kanagawa Y. Mesh-dependence and stress singularity in finite element analysis of creep crack growth by continuum damage mechanics approach. Eur J Mech A Solids 1994;13:395-418.
    • (1994) Eur J Mech A Solids , vol.13 , pp. 395-418
    • Liu, Y.1    Murakami, S.2    Kanagawa, Y.3
  • 27
    • 4644350527 scopus 로고    scopus 로고
    • Force transmission of one- and two-piece Morse-taper oral implants: A nonlinear finite element analysis
    • Cehreli MC, Akca K, Iplikcioglu H. Force transmission of one- and two-piece Morse-taper oral implants: A nonlinear finite element analysis. Clin Oral Implants Res 2004;15:481-489.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 481-489
    • Cehreli, M.C.1    Akca, K.2    Iplikcioglu, H.3
  • 28
    • 0031267997 scopus 로고    scopus 로고
    • 3D-FEA of osseointegration percentages and patterns on implant- bone interfacial stresses
    • Papavasiliou G, Kamposiora P, Bayne SC, Felton DA.3D-FEA of osseointegration percentages and patterns on implant- bone interfacial stresses.J Dent 1997;25:485-491.
    • (1997) J Dent , vol.25 , pp. 485-491
    • Papavasiliou, G.1    Kamposiora, P.2    Bayne, S.C.3    Felton, D.A.4
  • 29
    • 0000155741 scopus 로고
    • Elastic and mechanical properties of human dentin
    • Craig RG, Peyton FA. Elastic and mechanical properties of human dentin. J Dent Res 1958;37:710-718.
    • (1958) J Dent Res , vol.37 , pp. 710-718
    • Craig, R.G.1    Peyton, F.A.2
  • 31
    • 0029361203 scopus 로고
    • Force and moment distributions among osseointegrated dental implants
    • Morgan MJ, James DF. Force and moment distributions among osseointegrated dental implants. J Biomech 1995;28:1103-1109.
    • (1995) J Biomech , vol.28 , pp. 1103-1109
    • Morgan, M.J.1    James, D.F.2
  • 33
    • 33746903498 scopus 로고    scopus 로고
    • Biomechanical consequences of progressive marginal bone loss around oral implants: A finite element stress analysis
    • Akca K, Cehreli MC. Biomechanical consequences of progressive marginal bone loss around oral implants: A finite element stress analysis. Med Biol Eng Comput 2006;44:527-535.
    • (2006) Med Biol Eng Comput , vol.44 , pp. 527-535
    • Akca, K.1    Cehreli, M.C.2
  • 34
    • 0037208976 scopus 로고    scopus 로고
    • A mimic osseointegrated implant model for three-dimensional finite element analysis
    • Akagawa Y, Sato Y,Teixeira ER,Shindoi N,Wadamoto M.A mimic osseointegrated implant model for three-dimensional finite element analysis. J Oral Rehabil 2003;30:41-45.
    • (2003) J Oral Rehabil , vol.30 , pp. 41-45
    • Akagawa, Y.1    Sato, Y.2    Teixeira, E.R.3    Shindoi, N.4    Wadamoto, M.5
  • 35
    • 70350152448 scopus 로고    scopus 로고
    • A finite element stress analysis of the bone around implant following cervical bone resorption
    • Jung ES, Jo KH, Lee CH. A finite element stress analysis of the bone around implant following cervical bone resorption. J Korean Acad Implant Dent 2003;8:38-47.
    • (2003) J Korean Acad Implant Dent , vol.8 , pp. 38-47
    • Jung, E.S.1    Jo, K.H.2    Lee, C.H.3
  • 36
    • 0034577395 scopus 로고    scopus 로고
    • Buser D,von ArxT,ten BruggenkateC,Weingart D.Basic surgical principles with ITI implants
    • Buser D,von ArxT,ten BruggenkateC,Weingart D.Basic surgical principles with ITI implants. Clin Oral Implants Res 2000;11(suppl 1):59-68.
    • (2000) Clin Oral Implants Res , vol.11 , Issue.SUPPL 1 , pp. 59-68
  • 38
    • 0026266914 scopus 로고
    • Three -dimensional finite element stress analysis in and around the Screw-Vent implant
    • Clelland NL, Ismail YH,Zaki HS,Pipko D.Three -dimensional finite element stress analysis in and around the Screw-Vent implant. Int J Oral Maxillofac Implants 1991 ;6:391-398.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 391-398
    • Clelland, N.L.1    Ismail, Y.H.2    Zaki, H.S.3    Pipko, D.4
  • 39
    • 0035377329 scopus 로고    scopus 로고
    • Application of finite element analysis in implant dentistry: A review of the literature
    • Geng JP,Tan KB, Liu GR. Application of finite element analysis in implant dentistry: A review of the literature.J Prosthet Dent 2001;85:585-598.
    • (2001) J Prosthet Dent , vol.85 , pp. 585-598
    • Geng, J.P.1    Tan, K.B.2    Liu, G.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.