메뉴 건너뛰기




Volumn 42, Issue 8, 2009, Pages 1061-1068

Damage evolution in acetabular replacements under long-term physiological loading conditions

Author keywords

Cement fixation; Endurance testing; Fatigue damage; Implant loosening; Micro CT scan; Physiological loading

Indexed keywords

BLOCK LOADINGS; BONE-CEMENT INTERFACES; DAMAGE DEVELOPMENT; DAMAGE EVOLUTIONS; ENDURANCE TESTING; FATIGUE FAILURES; FINITE-ELEMENT ANALYSIS; HIP SIMULATOR STUDIES; HIP SIMULATORS; IMPLANT LOOSENING; IN-VITRO; MICRO-CT SCAN; MICROSCOPIC STUDIES; NORMAL WALKINGS; PELVIC BONES; PHYSIOLOGICAL LOADING; STAIR-CLIMBING;

EID: 67349211097     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2009.02.023     Document Type: Article
Times cited : (7)

References (20)
  • 1
    • 0024100992 scopus 로고
    • Density and temperature effects on some mechanical properties of cancellous bone
    • Brear K., Currey J.D., Raines S., and Smith K.J. Density and temperature effects on some mechanical properties of cancellous bone. Engineering in Medicine 17 4 (1988) 163-167
    • (1988) Engineering in Medicine , vol.17 , Issue.4 , pp. 163-167
    • Brear, K.1    Currey, J.D.2    Raines, S.3    Smith, K.J.4
  • 3
    • 67349098821 scopus 로고    scopus 로고
    • Bergmann, G., Graichen, F., Rohlmann, A., Deuretzbacher, G., Morlock, M., Heller, M., Duda, G., 1999. The hip joint: contact forces, gait data and load cycles, European Commission, contract SMT4-CT96-2076.
    • Bergmann, G., Graichen, F., Rohlmann, A., Deuretzbacher, G., Morlock, M., Heller, M., Duda, G., 1999. The hip joint: contact forces, gait data and load cycles, European Commission, contract SMT4-CT96-2076.
  • 5
    • 0017047304 scopus 로고
    • Radiological demarcation of cemented sockets in total hip replacement
    • DeLee J.G., and Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clinical Orthopaedics 121 (1976) 20-32
    • (1976) Clinical Orthopaedics , vol.121 , pp. 20-32
    • DeLee, J.G.1    Charnley, J.2
  • 6
    • 0026443614 scopus 로고
    • Early and late loosening of the acetabular cup after low-friction arthroplasty
    • Garcia-Cimbrelo E., and Munuera L. Early and late loosening of the acetabular cup after low-friction arthroplasty. Journal of Bone and Joint Surgery 74A (1992) 1119-1129
    • (1992) Journal of Bone and Joint Surgery , vol.74 A , pp. 1119-1129
    • Garcia-Cimbrelo, E.1    Munuera, L.2
  • 7
    • 33750322379 scopus 로고    scopus 로고
    • In-vitro fatigue behaviour of a cemented acetabular reconstruction
    • Heaton-Adegbile P., Zant N.P., and Tong J. In-vitro fatigue behaviour of a cemented acetabular reconstruction. Journal of Biomechanics 39 (2006) 2882-2886
    • (2006) Journal of Biomechanics , vol.39 , pp. 2882-2886
    • Heaton-Adegbile, P.1    Zant, N.P.2    Tong, J.3
  • 8
    • 0027715365 scopus 로고
    • Failed innovation in total hip replacement: diagnosis and proposals for a cure
    • Huiskes R. Failed innovation in total hip replacement: diagnosis and proposals for a cure. Acta Orthopaedica Scandinavia 64 (1993) 699-716
    • (1993) Acta Orthopaedica Scandinavia , vol.64 , pp. 699-716
    • Huiskes, R.1
  • 9
    • 0027489640 scopus 로고
    • Mechanical failure in total hip arthroplasty with cement
    • Huiskes R. Mechanical failure in total hip arthroplasty with cement. Current Orthopaedics 7 (1993) 239-247
    • (1993) Current Orthopaedics , vol.7 , pp. 239-247
    • Huiskes, R.1
  • 14
    • 0027301351 scopus 로고
    • The outcome of Charnley total hip arthroplasty with cement after a minimum twenty-year follow-up. The results of one surgeon
    • Schulte K.R., Callaghan J.J., Kelley S.S., and Johnston R.C. The outcome of Charnley total hip arthroplasty with cement after a minimum twenty-year follow-up. The results of one surgeon. Journal of Bone and Joint Surgery-American Volume 75 (1993) 961-975
    • (1993) Journal of Bone and Joint Surgery-American Volume , vol.75 , pp. 961-975
    • Schulte, K.R.1    Callaghan, J.J.2    Kelley, S.S.3    Johnston, R.C.4
  • 16
    • 0034989298 scopus 로고    scopus 로고
    • Hip-joint abductor-muscle forces adequately represent in vivo loading of a cemented total hip reconstruction
    • Stolk J., Verdonschot N., and Huiskes R. Hip-joint abductor-muscle forces adequately represent in vivo loading of a cemented total hip reconstruction. Journal of Biomechanics 34 (2001) 917-926
    • (2001) Journal of Biomechanics , vol.34 , pp. 917-926
    • Stolk, J.1    Verdonschot, N.2    Huiskes, R.3
  • 17
    • 33645776769 scopus 로고    scopus 로고
    • Aseptic loosening, not only a question of wear: a review of different theories
    • Sundfeldt M., Carlsson L.V., Johansson C.B., Thomsen P., and Gretzer C. Aseptic loosening, not only a question of wear: a review of different theories. Acta Orthopaedica 77 2 (2006) 177-197
    • (2006) Acta Orthopaedica , vol.77 , Issue.2 , pp. 177-197
    • Sundfeldt, M.1    Carlsson, L.V.2    Johansson, C.B.3    Thomsen, P.4    Gretzer, C.5
  • 19
    • 33947266526 scopus 로고    scopus 로고
    • Fatigue fracture in cement mantle in a simplified acetabular replacement model
    • Zant N.P., Wong K.Y., and Tong J. Fatigue fracture in cement mantle in a simplified acetabular replacement model. International Journal of Fatigue 29 7 (2008) 1245-1252
    • (2008) International Journal of Fatigue , vol.29 , Issue.7 , pp. 1245-1252
    • Zant, N.P.1    Wong, K.Y.2    Tong, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.