1
-
-
0032932956
-
Poor outcome of the PCA and Harris-Galante hip prostheses: randomized study of 171 arthroplasties with 9-year follow-up
-
Thanner J., Kaerrholm J., Malchau H., and Herberts P. Poor outcome of the PCA and Harris-Galante hip prostheses: randomized study of 171 arthroplasties with 9-year follow-up. Acta Orthop Scand 70 (1999) 155-162
-
(1999)
Acta Orthop Scand
, vol.70
, pp. 155-162
-
-
Thanner, J.1
Kaerrholm, J.2
Malchau, H.3
Herberts, P.4
-
3
-
-
0024954244
-
Biomechanical and histologic investigation of cemented total hip arthroplasties
-
Maloney W.J., Murali J., Burke D.W., O'Connor D.O., Zalenski E.B., Braydon C., et al. Biomechanical and histologic investigation of cemented total hip arthroplasties. Clin Orthop Rel Res 249 (1989) 129-140
-
(1989)
Clin Orthop Rel Res
, vol.249
, pp. 129-140
-
-
Maloney, W.J.1
Murali, J.2
Burke, D.W.3
O'Connor, D.O.4
Zalenski, E.B.5
Braydon, C.6
-
4
-
-
0025388865
-
A fractographic analysis of in vivo poly(methylmethacrylate) bone cement failure mechanisms
-
Topoleski L.D.T., Duchegne P., Cucheyne P., and Cuckler J.M. A fractographic analysis of in vivo poly(methylmethacrylate) bone cement failure mechanisms. J Biomed Mater Res 24 (1990) 135-154
-
(1990)
J Biomed Mater Res
, vol.24
, pp. 135-154
-
-
Topoleski, L.D.T.1
Duchegne, P.2
Cucheyne, P.3
Cuckler, J.M.4
-
5
-
-
0025784682
-
The initiation of failure in cemented femoral components of hip arthroplasties
-
Jasty M., Maloney W.J., Bragdon C.R., O'Connor D.O., Haire T., and Harris H.H. The initiation of failure in cemented femoral components of hip arthroplasties. J Bone Joint Surg Br 73B (1991) 551-558
-
(1991)
J Bone Joint Surg Br
, vol.73 B
, pp. 551-558
-
-
Jasty, M.1
Maloney, W.J.2
Bragdon, C.R.3
O'Connor, D.O.4
Haire, T.5
Harris, H.H.6
-
6
-
-
0027533403
-
Fatigue failure in the cement of an artificial hip joint
-
Culleton T.P., Prendergast P.J., and Taylor D. Fatigue failure in the cement of an artificial hip joint. Clin Mater 12 (1993) 95-102
-
(1993)
Clin Mater
, vol.12
, pp. 95-102
-
-
Culleton, T.P.1
Prendergast, P.J.2
Taylor, D.3
-
7
-
-
0030175862
-
An experimental study of damage accumulation in cemented hip prostheses
-
McCormack B.A.O., Prendergast P.J., and Gallagher D.G. An experimental study of damage accumulation in cemented hip prostheses. Clin Biomech 11 (1996) 214-219
-
(1996)
Clin Biomech
, vol.11
, pp. 214-219
-
-
McCormack, B.A.O.1
Prendergast, P.J.2
Gallagher, D.G.3
-
8
-
-
0032897980
-
Microdamage accumulation in the cement layer of hip replacements under flexural loading
-
McCormack B.A.O., and Prendergast P.J. Microdamage accumulation in the cement layer of hip replacements under flexural loading. J Biomech 32 (1999) 467-475
-
(1999)
J Biomech
, vol.32
, pp. 467-475
-
-
McCormack, B.A.O.1
Prendergast, P.J.2
-
9
-
-
3343006998
-
Cement microcracks in thin-mantle regions after in vitro fatigue loading
-
Mann K.A., Gupta S., Race A., Miller M.A., Cleary R.J., and Ayers D.C. Cement microcracks in thin-mantle regions after in vitro fatigue loading. J Arthroplasty 19 (2004) 605-612
-
(2004)
J Arthroplasty
, vol.19
, pp. 605-612
-
-
Mann, K.A.1
Gupta, S.2
Race, A.3
Miller, M.A.4
Cleary, R.J.5
Ayers, D.C.6
-
10
-
-
0345581246
-
Finite element simulation of anisotropic damage accumulation and creep in acrylic bone cement
-
Stolk J., Verdonschot N., Murphy B.P., Predergast P.J., and Huiskes R. Finite element simulation of anisotropic damage accumulation and creep in acrylic bone cement. Eng Fract Mech 7 (2004) 513-528
-
(2004)
Eng Fract Mech
, vol.7
, pp. 513-528
-
-
Stolk, J.1
Verdonschot, N.2
Murphy, B.P.3
Predergast, P.J.4
Huiskes, R.5
-
11
-
-
0036643309
-
Fatigue analysis of cemented hip prosthesis: damage accumulation scenario and sensitivity analysis
-
Colombi P. Fatigue analysis of cemented hip prosthesis: damage accumulation scenario and sensitivity analysis. Int J Fatigue 24 (2002) 739-746
-
(2002)
Int J Fatigue
, vol.24
, pp. 739-746
-
-
Colombi, P.1
-
12
-
-
4644221748
-
Computer simulation on fatigue behaviour of cemented hip prostheses: a physiological model
-
Hung J.-P., Chen J.-H., Chiang H.-L., and Wu J.S.-S. Computer simulation on fatigue behaviour of cemented hip prostheses: a physiological model. Comput Meth Prog Biomed 76 (2004) 103-113
-
(2004)
Comput Meth Prog Biomed
, vol.76
, pp. 103-113
-
-
Hung, J.-P.1
Chen, J.-H.2
Chiang, H.-L.3
Wu, J.S.-S.4
-
13
-
-
0027715365
-
Failed innovation in total hip replacement
-
Huiskes R. Failed innovation in total hip replacement. Acta Orthop Scand 64 (1993) 699-716
-
(1993)
Acta Orthop Scand
, vol.64
, pp. 699-716
-
-
Huiskes, R.1
-
14
-
-
0027301351
-
The outcome of Charnley total hip arthroplasty with cement after a minimum twenty-year follow-up. The results of one surgeon
-
Schulte K.R., Callaghan J.J., Kelley S.S., and Johnston R.C. The outcome of Charnley total hip arthroplasty with cement after a minimum twenty-year follow-up. The results of one surgeon. J Bone Joint Surg Am 75 (1993) 961-975
-
(1993)
J Bone Joint Surg Am
, vol.75
, pp. 961-975
-
-
Schulte, K.R.1
Callaghan, J.J.2
Kelley, S.S.3
Johnston, R.C.4
-
15
-
-
33947253157
-
-
Huiskes R, Stolk J. Biomechanics and preclinical testing of artificial joints: the hip. In: Basic orthopaedic biomechanics and mechano-biology. Lippincott Williams & Wilkins, Philadelphia, USA.
-
-
-
-
16
-
-
0022353611
-
Contact finite element stress analysis of the hip joint
-
Rapperport D.J., Carter D.R., and Schurman D.J. Contact finite element stress analysis of the hip joint. J Orthop Res 3 (1985) 435-446
-
(1985)
J Orthop Res
, vol.3
, pp. 435-446
-
-
Rapperport, D.J.1
Carter, D.R.2
Schurman, D.J.3
-
18
-
-
0036046684
-
Analysis of contact mechanics in ceramic-on-ceramic hip joint replacements
-
Mak M.M., and Jin Z.-M. Analysis of contact mechanics in ceramic-on-ceramic hip joint replacements. Proc Inst Mech Eng, Part H, Eng Med 216 (2002) 231-236
-
(2002)
Proc Inst Mech Eng, Part H, Eng Med
, vol.216
, pp. 231-236
-
-
Mak, M.M.1
Jin, Z.-M.2
-
19
-
-
0034984126
-
contact forces and gait patterns from routine activities
-
Bergmann G., Deuretzbacher G., Heller M., Graichen F., Rohlmann A., Strauss J., et al. contact forces and gait patterns from routine activities. J Biomech 34 (2001) 859-872
-
(2001)
J Biomech
, vol.34
, pp. 859-872
-
-
Bergmann, G.1
Deuretzbacher, G.2
Heller, M.3
Graichen, F.4
Rohlmann, A.5
Strauss, J.6
-
20
-
-
0347384111
-
Fatigue properties of acrylic bone cements: review of the literature
-
Lewis G. Fatigue properties of acrylic bone cements: review of the literature. J Biomed Mater Res 66B (2003) 457-486
-
(2003)
J Biomed Mater Res
, vol.66 B
, pp. 457-486
-
-
Lewis, G.1
-
21
-
-
33947283110
-
Fatigue testing and performance of acrylic bone-cement materials: state-of-art review
-
Lewis G. Fatigue testing and performance of acrylic bone-cement materials: state-of-art review. J Biomed Mater Res: Appl Biomater 22 A1 (1988) 37-53
-
(1988)
J Biomed Mater Res: Appl Biomater
, vol.22
, Issue.A1
, pp. 37-53
-
-
Lewis, G.1
-
22
-
-
0037397195
-
Early cement damage around a femoral stem is concentrated at the cement/bone interface
-
Race A., Miller M.A., Ayers D.C., and Mann K.A. Early cement damage around a femoral stem is concentrated at the cement/bone interface. J Biomech 36 (2003) 489-496
-
(2003)
J Biomech
, vol.36
, pp. 489-496
-
-
Race, A.1
Miller, M.A.2
Ayers, D.C.3
Mann, K.A.4
-
23
-
-
0034307325
-
On fatigue lifetimes and fatigue crack growth behaviour of bone cement
-
Ishihara S., McEvily A.J., Goshima T., Kanekasu K., and Nara T. On fatigue lifetimes and fatigue crack growth behaviour of bone cement. J Mater Sci: Mater Med 11 (2000) 661-666
-
(2000)
J Mater Sci: Mater Med
, vol.11
, pp. 661-666
-
-
Ishihara, S.1
McEvily, A.J.2
Goshima, T.3
Kanekasu, K.4
Nara, T.5
-
24
-
-
33947249394
-
-
Hong T, Wang J-Y, Zant NP, Heaton-Adegbile P, Hussell JG, Tong J. A comparison of 2D and 3D acetabular models in the assessment of fatigue integrity of cement fixation. Unpublished work.
-
-
-
-
25
-
-
33750322379
-
In-vitro fatigue behaviour of a cemented acetabular reconstruction
-
Heaton-Adegbile P., Zant N P., and Tong J. In-vitro fatigue behaviour of a cemented acetabular reconstruction. J Biomech 39 (2006) 2882-2886
-
(2006)
J Biomech
, vol.39
, pp. 2882-2886
-
-
Heaton-Adegbile, P.1
Zant N, P.2
Tong, J.3
|