Volumn 23, Issue 3, 2009, Pages 169-174

A poor correlation exists between oscillometric and radial arterial blood pressure as measured by the Philips MP90 monitor

Author keywords

Anesthesia monitoring; Blood pressure accuracy; Blood pressure monitoring; Invasive monitoring

Indexed keywords

ADULT PATIENTS; ANESTHESIA MONITORING; ARTERIAL BLOOD PRESSURE; BLOOD PRESSURE MONITORING; CONFIDENCE INTERVAL; CORRELATION ANALYSIS; CRITICAL CARE; DIASTOLIC PRESSURE; GOLD STANDARDS; INVASIVE MONITORING; MEAN ARTERIAL PRESSURE; MEAN PRESSURES; MEASUREMENT SYSTEM; MEDICAL CENTER; MEDICAL INSTRUMENTATION; PHILIPS; R VALUE; STANDARD DEVIATION; STANFORD UNIVERSITY; SURGICAL PROCEDURES;

EID: 67349105014     PISSN: 13871307     EISSN: 15732614     Source Type: Journal    
DOI: 10.1007/s10877-009-9178-8     Document Type: Article
Times cited : (15)

References (17)
  • 2
    • 0027491583 scopus 로고
    • Factors affecting the validity of the standard blood pressure cuff
    • Stolt M, Sjönell G, Aström H, Hansson L. Factors affecting the validity of the standard blood pressure cuff. Clin Physiol. 1993;13(6):611-20.
    • (1993) Clin Physiol , vol.13 , Issue.6 , pp. 611-620
    • Stolt, M.1    Sjönell, G.2    Aström, H.3    Hansson, L.4
  • 4
    • 0021654928 scopus 로고
    • Comparison between oscillometric and invasive blood pressure monitoring during cardiac surgery
    • Green M, Paulus DA, Roan VP, Van der Aa J. Comparison between oscillometric and invasive blood pressure monitoring during cardiac surgery. Int J Clin Monit Comput. 1984;1(1):21-6.
    • (1984) Int J Clin Monit Comput , vol.1 , Issue.1 , pp. 21-26
    • Green, M.1    Paulus, D.A.2    Roan, V.P.3    Van der Aa, J.4
  • 5
    • 0026543601 scopus 로고
    • Non-invasive vs. invasive beat-to-beat monitoring of blood pressure
    • Gabriel A, Lindblad LE, Angleryd C. Non-invasive vs. invasive beat-to-beat monitoring of blood pressure. Clin Physiol. 1992;12(2):229-35.
    • (1992) Clin Physiol , vol.12 , Issue.2 , pp. 229-235
    • Gabriel, A.1    Lindblad, L.E.2    Angleryd, C.3
  • 6
    • 0022508729 scopus 로고
    • A comparative study of the measurement of mean arterial blood pressure using automatic oscillometers, arterial cannulation and auscultation
    • Rutten AJ, Ilsley AH, Skowronski GA, Runciman WB. A comparative study of the measurement of mean arterial blood pressure using automatic oscillometers, arterial cannulation and auscultation. Anaesth Intensive Care. 1986;14(1):58-65.
    • (1986) Anaesth Intensive Care , vol.14 , Issue.1 , pp. 58-65
    • Rutten, A.J.1    Ilsley, A.H.2    Skowronski, G.A.3    Runciman, W.B.4
  • 7
    • 0033651835 scopus 로고    scopus 로고
    • How accurate is invasive blood pressure determination with fluid-filled pressure line systems?
    • Francke A, Wachsmuth H. How accurate is invasive blood pressure determination with fluid-filled pressure line systems? Anaesthesiol Reanim. 2000;25(2):46-54.
    • (2000) Anaesthesiol Reanim , vol.25 , Issue.2 , pp. 46-54
    • Francke, A.1    Wachsmuth, H.2
  • 9
    • 0027218269 scopus 로고
    • The British Hypertension Society Protocol for the evaluation of blood pressure measuring devices
    • O'Brien E, Petrie J, Littler WA, de Swiet M, Padfield PL, Altman D, et al. The British Hypertension Society Protocol for the evaluation of blood pressure measuring devices. J Hypertens. 1993;11(Suppl 2):S43-63.
    • (1993) J Hypertens , vol.11 , Issue.SUPPL. 2
    • O'Brien, E.1    Petrie, J.2    Littler, W.A.3    de Swiet, M.4    Padfield, P.L.5    Altman, D.6
  • 10
    • 0027218269 scopus 로고
    • Short report. An outline of the British Hypertension Society Protocol for the evaluation of blood pressure measuring devices
    • O'Brien E, Petrie J, Littler WA, de Swiet M, Padfield PL, Altman D, et al. Short report. An outline of the British Hypertension Society Protocol for the evaluation of blood pressure measuring devices. J Hypertens. 1993;11:677-9.
    • (1993) J Hypertens , vol.11 , pp. 677-679
    • O'Brien, E.1    Petrie, J.2    Littler, W.A.3    de Swiet, M.4    Padfield, P.L.5    Altman, D.6
  • 11
    • 0035799041 scopus 로고    scopus 로고
    • Blood pressure measuring devices: Recommendations of the European Society of Hypertension
    • O'Brien E, Waeber B, Parati G, Staessen J, Myers M. Blood pressure measuring devices: Recommendations of the European Society of Hypertension. BMJ. 2001;322:531-6.
    • (2001) BMJ , vol.322 , pp. 531-536
    • O'Brien, E.1    Waeber, B.2    Parati, G.3    Staessen, J.4    Myers, M.5
  • 12
    • 0035527544 scopus 로고    scopus 로고
    • State of the market for devices for blood pressure measurement
    • O'Brien E. State of the market for devices for blood pressure measurement. Blood Press Monit. 2001;6(6):281-6.
    • (2001) Blood Press Monit , vol.6 , Issue.6 , pp. 281-286
    • O'Brien, E.1
  • 13
    • 43449127787 scopus 로고    scopus 로고
    • Noninvasive assessment of arterial pressure
    • Chemla D, Teboul JL, Richard C. Noninvasive assessment of arterial pressure. Curr Opin Crit Care. 2008;14(3):317-21.
    • (2008) Curr Opin Crit Care , vol.14 , Issue.3 , pp. 317-321
    • Chemla, D.1    Teboul, J.L.2    Richard, C.3
  • 14
    • 34248369753 scopus 로고    scopus 로고
    • Comparison of noninvasive oscillometric and intra-arterial blood pressure measurements in hyperacute stroke
    • Manios E, Vemmos K, Tsivgoulis G, Barlas G, Koroboki E, Spengos K, et al. Comparison of noninvasive oscillometric and intra-arterial blood pressure measurements in hyperacute stroke. Blood Press Monit. 2007;12(3):149-56.
    • (2007) Blood Press Monit , vol.12 , Issue.3 , pp. 149-156
    • Manios, E.1    Vemmos, K.2    Tsivgoulis, G.3    Barlas, G.4    Koroboki, E.5    Spengos, K.6
  • 15
    • 37349087844 scopus 로고    scopus 로고
    • Automatic blood pressure measurement: The oscillometric waveform shape is a potential contributor to differences between oscillometric and auscultatory pressure measurements
    • Amoore JN, Lemesre Y, Murray IC, Mieke S, King ST, Smith FE, et al. Automatic blood pressure measurement: The oscillometric waveform shape is a potential contributor to differences between oscillometric and auscultatory pressure measurements. J Hypertens. 2008;26(1):35-43.
    • (2008) J Hypertens , vol.26 , Issue.1 , pp. 35-43
    • Amoore, J.N.1    Lemesre, Y.2    Murray, I.C.3    Mieke, S.4    King, S.T.5    Smith, F.E.6
  • 16
    • 34648832866 scopus 로고    scopus 로고
    • Effect of the shapes of the oscillometric pulse amplitude envelopes and their characteristic ratios on the differences between auscultatory and oscillometric blood pressure measurements
    • Amoore JN, Vacher E, Murray IC, Mieke S, King ST, Smith FE, et al. Effect of the shapes of the oscillometric pulse amplitude envelopes and their characteristic ratios on the differences between auscultatory and oscillometric blood pressure measurements. Blood Press Monit. 2007;12(5):297-305.
    • (2007) Blood Press Monit , vol.12 , Issue.5 , pp. 297-305
    • Amoore, J.N.1    Vacher, E.2    Murray, I.C.3    Mieke, S.4    King, S.T.5    Smith, F.E.6
  • 17
    • 0035992025 scopus 로고    scopus 로고
    • International protocol for validation of blood pressure measuring devices in adults
    • with the statistical assistance of Atkins N and Gerin W on behalf of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension
    • O'Brien E, Pickering T, Asmar R, Myers M, Parati G, Staessen J, Mengden T, Imai Y, Waeber B, Palatini P with the statistical assistance of Atkins N and Gerin W on behalf of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension. International protocol for validation of blood pressure measuring devices in adults. Blood Press Monit 2002; 7: 3-17.
    • (2002) Blood Press Monit , vol.7 , pp. 3-17
    • O'Brien, E.1    Pickering, T.2    Asmar, R.3    Myers, M.4    Parati, G.5    Staessen, J.6    Mengden, T.7    Imai, Y.8    Waeber, B.9    Palatini, P.10


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.