Effect of the shapes of the oscillometric pulse amplitude envelopes and their characteristic ratios on the differences between auscultatory and oscillometric blood pressure measurements

Author keywords

Characteristic ratios; Oscillometric noninvasive blood pressure; Oscillometric waveform shape; Oscillometric auscultatory pressure differences; Simulators

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; AUSCULTATION; BLOOD PRESSURE CUFF; BLOOD PRESSURE MEASUREMENT; DIASTOLIC BLOOD PRESSURE; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; OSCILLOMETRY; PRIORITY JOURNAL; REFERENCE VALUE; SCHOOL CHILD; SIMULATOR; SYSTOLIC BLOOD PRESSURE; WAVEFORM;

EID: 34648832866     PISSN: 13595237     EISSN: None     Source Type: Journal    
DOI: 10.1097/MBP.0b013e32826fb773     Document Type: Article
Times cited : (38)

References (17)
  • 1
    • 0018376613 scopus 로고
    • Noninvasive automatic determination of mean arterial blood pressure
    • Ramsey M, III. Noninvasive automatic determination of mean arterial blood pressure. Med Biol Eng Computing 1979; 17:11-18.
    • (1979) Med Biol Eng Computing , vol.17 , pp. 11-18
    • Ramsey III, M.1
  • 2
    • 0020307159 scopus 로고
    • Characterisation of the oscillometric method for measuring indirect blood pressure
    • Geddes LA, Voelz M, Combs C, Reiner D, Babbs CF. Characterisation of the oscillometric method for measuring indirect blood pressure. Annal Biomed Eng 1982; 10:271-280.
    • (1982) Annal Biomed Eng , vol.10 , pp. 271-280
    • Geddes, L.A.1    Voelz, M.2    Combs, C.3    Reiner, D.4    Babbs, C.F.5
  • 3
    • 0030110895 scopus 로고    scopus 로고
    • An arm phantom: A digital simulation system for testing sphygmomanometers
    • Groß H, Mieke S, Ulbrich M. An arm phantom: a digital simulation system for testing sphygmomanometers. J Med Eng & Tech 1996; 20:75-83.
    • (1996) J Med Eng & Tech , vol.20 , pp. 75-83
    • Groß, H.1    Mieke, S.2    Ulbrich, M.3
  • 4
    • 0030221353 scopus 로고    scopus 로고
    • A mathematical study of some biomechanical factors affecting the oscillometric blood pressure measurement
    • Ursino M, Cristalli C. A mathematical study of some biomechanical factors affecting the oscillometric blood pressure measurement. IEEE Trans Biomed Eng 1996; 43:761-778.
    • (1996) IEEE Trans Biomed Eng , vol.43 , pp. 761-778
    • Ursino, M.1    Cristalli, C.2
  • 5
    • 1542344282 scopus 로고
    • Standard algorithm of blood-pressure measurement by the oscillometric method [letter]
    • Sapinski A. Standard algorithm of blood-pressure measurement by the oscillometric method [letter]. Med Biol Eng Computing 1992; 30:671.
    • (1992) Med Biol Eng Computing , vol.30 , pp. 671
    • Sapinski, A.1
  • 6
    • 33744508715 scopus 로고    scopus 로고
    • Can a simulator that regenerates physiological waveforms evaluate oscillometric non-invasive blood pressure devices?
    • Amoore JN, Vacher E, Murray IC, Mieke S, King ST, Smith FE, Murray A. Can a simulator that regenerates physiological waveforms evaluate oscillometric non-invasive blood pressure devices? Blood Press Monit 2006; 11:63-67.
    • (2006) Blood Press Monit , vol.11 , pp. 63-67
    • Amoore, J.N.1    Vacher, E.2    Murray, I.C.3    Mieke, S.4    King, S.T.5    Smith, F.E.6    Murray, A.7
  • 7
    • 0034959116 scopus 로고    scopus 로고
    • Evaluation of the overall efficacy of the Omron office digital blood pressure HEM-907 monitor in adults
    • White WB, Anwar YA. Evaluation of the overall efficacy of the Omron office digital blood pressure HEM-907 monitor in adults. Blood Press Monit 2001; 6:107-110.
    • (2001) Blood Press Monit , vol.6 , pp. 107-110
    • White, W.B.1    Anwar, Y.A.2
  • 9
    • 0027479012 scopus 로고
    • National standard for measurement of resting and ambulatory blood pressure with automated sphygmomanometers
    • White WB, Berson AS, Robbins C, Jamieson MJ, Prisant LM, Roccella E, et al. National standard for measurement of resting and ambulatory blood pressure with automated sphygmomanometers. Hypertension 1993; 21:504-509.
    • (1993) Hypertension , vol.21 , pp. 504-509
    • White, W.B.1    Berson, A.S.2    Robbins, C.3    Jamieson, M.J.4    Prisant, L.M.5    Roccella, E.6
  • 10
    • 34648846923 scopus 로고    scopus 로고
    • Test procedures to determine the overall system accuracy of automated non-invasive sphygmomanometers. 2004. ISBN 058044542 9
    • EN 1060-4
    • EN 1060-4: 2004. Test procedures to determine the overall system accuracy of automated non-invasive sphygmomanometers. 2004. ISBN 058044542 9.
    • (2004)
  • 11
    • 0028532654 scopus 로고
    • Survey of automated noninvasive blood pressure monitors
    • Ng KG, Small CF. Survey of automated noninvasive blood pressure monitors. J Clin Eng 1994; 19:452-475.
    • (1994) J Clin Eng , vol.19 , pp. 452-475
    • KG, N.1    Small, C.F.2
  • 12
    • 0029956336 scopus 로고    scopus 로고
    • A comparison of non-invasive methods of blood pressure measurement in normotensive and hypertensive pregnant women
    • Arfeen ZU, Maran NJ, Simon EJ, McClure JH. A comparison of non-invasive methods of blood pressure measurement in normotensive and hypertensive pregnant women. Int J Obstet Anesth 1996; 5:168-171.
    • (1996) Int J Obstet Anesth , vol.5 , pp. 168-171
    • Arfeen, Z.U.1    Maran, N.J.2    Simon, E.J.3    McClure, J.H.4
  • 13
    • 0035061763 scopus 로고    scopus 로고
    • Blood pressure monitoring during pregnancy
    • Feldman DB. Blood pressure monitoring during pregnancy. Blood Press Monit 2001; 6:1-7.
    • (2001) Blood Press Monit , vol.6 , pp. 1-7
    • Feldman, D.B.1
  • 15
    • 0031874834 scopus 로고    scopus 로고
    • Determinants of the limits of agreement between the sphygmomanometer and the Spacelabs 90207 device for blood pressure measurement in healthy volunteers and insulin-dependent diabetic patients
    • Van Ittersum FJ, Wijering RM, Lambert J, Donker AJ, Stehouwer CD. Determinants of the limits of agreement between the sphygmomanometer and the Spacelabs 90207 device for blood pressure measurement in healthy volunteers and insulin-dependent diabetic patients. J Hypertens 1998; 16:1125-1130.
    • (1998) J Hypertens , vol.16 , pp. 1125-1130
    • Van Ittersum, F.J.1    Wijering, R.M.2    Lambert, J.3    Donker, A.J.4    Stehouwer, C.D.5
  • 16
    • 0035799041 scopus 로고    scopus 로고
    • Blood pressure measuring devices: Recommendations of the European Society of Hypertension
    • O'Brien E, Waeber B, Parati G, Staessen J, Myers MG. Blood pressure measuring devices: recommendations of the European Society of Hypertension. Br Med J 2001; 322:531-536.
    • (2001) Br Med J , vol.322 , pp. 531-536
    • O'Brien, E.1    Waeber, B.2    Parati, G.3    Staessen, J.4    Myers, M.G.5
  • 17
    • 0035527552 scopus 로고    scopus 로고
    • Oscillometric blood pressure measurement: Progress and problems
    • van Montfrans GA. Oscillometric blood pressure measurement: progress and problems. Blood Press Monit 2001; 6:287-290.
    • (2001) Blood Press Monit , vol.6 , pp. 287-290
    • van Montfrans, G.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.