메뉴 건너뛰기




Volumn 29, Issue 6, 2009, Pages 1414-1424

Shielded dual-loop resonator for arterial spin labeling at the neck

Author keywords

Continuous arterial spin labeling; Labeling coil; Perfusion, two coil CASL

Indexed keywords

POLYPROPYLENE;

EID: 66749086284     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.21803     Document Type: Article
Times cited : (9)

References (36)
  • 2
    • 34548183746 scopus 로고    scopus 로고
    • Assessment of collateral supply by two-coil continuous arterial spin labeling after coil occlusion of the internal carotid artery
    • DOI 10.3174/ajnr.A0552
    • Möller HE, Mildner T, Preul C, Zimmer C, von Cramon DY. Assessment of collateral supply by two-coil continuous arterial spin labeling after coil occlusion of the internal carotid artery. AJNR Am J Neuroradiol 2007;28:1304-1305. (Pubitemid 47309663)
    • (2007) American Journal of Neuroradiology , vol.28 , Issue.7 , pp. 1304-1305
    • Moller, H.E.1    Mildner, T.2    Preul, C.3    Zimmer, C.4    Yves Von Cramon, D.5
  • 3
    • 24944476586 scopus 로고    scopus 로고
    • Towards quantification of blood-flow changes during cognitive task activation using perfusion-based fMRI
    • DOI 10.1016/j.neuroimage.2005.04.040, PII S1053811905003186
    • Mildner T, Zysset S, Trampel R, Driesel W, Möller HE. Towards quantification of blood-flow changes during cognitive task activation using perfusion-based fMRI. NeuroImage 2005;27:919-926. (Pubitemid 41317260)
    • (2005) NeuroImage , vol.27 , Issue.4 , pp. 919-926
    • Mildner, T.1    Zysset, S.2    Trampel, R.3    Driesel, W.4    Moller, H.E.5
  • 8
    • 14844290242 scopus 로고    scopus 로고
    • Continuous arterial spin labeling at the human common carotid artery: The influence of transit times
    • DOI 10.1002/nbm.917
    • Mildner T, Möller HE, Driesel W, Norris DG, Trampel R. Continuous arterial spin labeling at the human common carotid artery: the influence of transit times. NMR Biomed 2005;18:19-23. (Pubitemid 40347539)
    • (2005) NMR in Biomedicine , vol.18 , Issue.1 , pp. 19-23
    • Mildner, T.1    Moller, H.E.2    Driesel, W.3    Norris, D.G.4    Trampel, R.5
  • 9
    • 0031876165 scopus 로고    scopus 로고
    • Multisection cerebral blood flow MRI imaging with continuous arterial spin labeling
    • Alsop DC, Detre JA. Multisection cerebral blood flow MR imaging with continuous arterial spin labeling. Radiology 1998;208:410-416. (Pubitemid 28373748)
    • (1998) Radiology , vol.208 , Issue.2 , pp. 410-416
    • Alsop, D.C.1    Detre, J.A.2
  • 10
    • 15944405346 scopus 로고    scopus 로고
    • Amplitude-modulated continuous arterial spin-labeling 3.0-T perfusion MR imaging with a single coil: Feasibility study
    • DOI 10.1148/radiol.2351031663
    • Wang J, Zhang Y, Wolf RL, Roc AC, Alsop DC, Detre JA. Amplitude-modulated continuous arterial spin-labeling 3.0-T perfusion MR imaging with a single coil: feasibility study. Radiology 2005;235:218-228. (Pubitemid 40432258)
    • (2005) Radiology , vol.235 , Issue.1 , pp. 218-228
    • Wang, J.1    Zhang, Y.2    Wolf, R.L.3    Roc, A.C.4    Alsop, D.C.5    Detre, J.A.6
  • 11
    • 0033033852 scopus 로고    scopus 로고
    • Multislice perfusion and perfusion territory imaging in humans with separate label and image coils
    • DOI 10.1002/(SICI)1522-2594(199906)41:6<1093::AID-MRM4>3.0.CO;2-0
    • Zaharchuk G, Ledden PJ, Kwong KK, Reese TG, Rosen BR, Wald LL. Multislice perfusion and perfusion territory imaging in humans with separate label and image coils. Magn Reson Med 1999;41:1093-1098. (Pubitemid 29247276)
    • (1999) Magnetic Resonance in Medicine , vol.41 , Issue.6 , pp. 1093-1098
    • Zaharchuk, G.1    Ledden, P.J.2    Kwong, K.K.3    Reese, T.G.4    Rosen, B.R.5    Wald, L.L.6
  • 13
    • 0037407695 scopus 로고    scopus 로고
    • Functional perfusion imaging using continuous arterial spin labeling with separate labeling and imaging coils at 3 T
    • DOI 10.1002/mrm.10438
    • Mildner T, Trampel R, Möller HE, Schäfer A, Wiggins CJ, Norris DG. Functional perfusion imaging using continuous arterial spin labeling with separate labeling and imaging coils at 3 T. Magn Reson Med 2003;49:791-795. (Pubitemid 36523463)
    • (2003) Magnetic Resonance in Medicine , vol.49 , Issue.5 , pp. 791-795
    • Mildner, T.1    Trampel, R.2    Moller, H.E.3    Schafer, A.4    Wiggins, C.J.5    Norris, D.G.6
  • 14
    • 1542346910 scopus 로고    scopus 로고
    • Fast Pseudo-Continuous Arterial Spin Labeling for Functional Imaging Using a Two-Coil System
    • DOI 10.1002/mrm.10733
    • Hernandez-Garcia L, Lee GR, Vazquez AL, Noll DC. Fast, pseudocontinuous arterial spin labeling for functional imaging using a two-coil system. Magn Reson Med 2004;51:577-585. (Pubitemid 38298672)
    • (2004) Magnetic Resonance in Medicine , vol.51 , Issue.3 , pp. 577-585
    • Hernandez-Garcia, L.1    Lee, G.R.2    Vazquez, A.L.3    Noll, D.C.4
  • 15
    • 4644225113 scopus 로고    scopus 로고
    • Whole-brain 3D perfusion MRI at 3.0 T using CASL with a separate labeling coil
    • DOI 10.1002/mrm.20124
    • Talagala SL, Ye FQ, Ledden PJ, Chesnick S. Whole-brain 3D perfusion MRI at 3.0 T using CASL with a separate labeling coil. Magn Reson Med 2004;52:131-140. (Pubitemid 39295265)
    • (2004) Magnetic Resonance in Medicine , vol.52 , Issue.1 , pp. 131-140
    • Talagala, S.L.1    Ye, F.Q.2    Ledden, P.J.3    Chesnick, S.4
  • 16
    • 0032857913 scopus 로고    scopus 로고
    • Pseudo-continuous arterial spin labeling technique for measuring CBF dynamics with high temporal resolution
    • DOI 10.1002/(SICI)1522-2594(199909)42:3<425::AID-MRM3>3.0.CO;2-S
    • Silva AC, Kim SG. Pseudo-continuous arterial spin labeling technique for measuring CBF dynamics with high temporal resolution. Magn Reson Med 1999;42:425-429. (Pubitemid 29416202)
    • (1999) Magnetic Resonance in Medicine , vol.42 , Issue.3 , pp. 425-429
    • Silva, A.C.1    Kim, S.-G.2
  • 18
    • 0023512971 scopus 로고
    • High-quality MR imaging with flexible transmission line resonators
    • Zabel HJ, Bader R, Gehrig J, Lorenz WJ. High-quality MR imaging with flexible transmission line resonators. Radiology 1987;165:857-859. (Pubitemid 18003228)
    • (1987) Radiology , vol.165 , Issue.3 , pp. 857-859
    • Zabel, H.-J.1    Bader, R.2    Gehrig, J.3    Lorenz, W.J.4
  • 19
    • 0028130688 scopus 로고
    • The theory of shielded loop resonators
    • DOI 10.1002/mrm.1910320615
    • Harpen MD. The theory of shielded loop resonators. Magn Reson Med 1994;32:785-788. (Pubitemid 24371181)
    • (1994) Magnetic Resonance in Medicine , vol.32 , Issue.6 , pp. 785-788
    • Harpen, M.D.1
  • 20
  • 21
    • 0034405181 scopus 로고    scopus 로고
    • The principle of reciprocity in signal strength calculations - A mathematical guide
    • Hoult DI. The principle of reciprocity in signal strength calculations - a mathematical guide. Concepts Magn Reson 2000;12:173-187.
    • (2000) Concepts Magn Reson , vol.12 , pp. 173-187
    • Hoult, D.I.1
  • 23
    • 0022799215 scopus 로고
    • The field dependence of NMR imaging. I. Laboratory assessment of signal-to-noise ratio and power deposition
    • Chen CN, Sank, VJ, Cohen SM, Hoult DI. The field dependence of NMR imaging. I. Laboratory assessment of signal-to-noise ratio and power deposition. Magn Reson Med 1986;3:722-729.
    • (1986) Magn Reson Med , vol.3 , pp. 722-729
    • Chen, C.N.1    Sank, V.J.2    Cohen, S.M.3    Hoult, D.I.4
  • 24
    • 2942699891 scopus 로고    scopus 로고
    • Efficiency of flow-driven adiabatic spin inversion under realistic experimental conditions: A computer simulation
    • DOI 10.1002/mrm.20080
    • Trampel R, Jochimsen TH, Mildner T, Norris DG, Möller HE. Efficiency of flow-driven adiabatic spin inversion under realistic experimental conditions: a computer simulation. Magn Reson Med 2004;51:1187-1193. (Pubitemid 38797004)
    • (2004) Magnetic Resonance in Medicine , vol.51 , Issue.6 , pp. 1187-1193
    • Trampel, R.1    Jochimsen, T.H.2    Mildner, T.3    Norris, D.G.4    Moller, H.E.5
  • 26
    • 0003184979 scopus 로고
    • Council Directive 93/42/EEC of 14 June 1993 concerning medical devices
    • Council Directive 93/42/EEC of 14 June 1993 concerning medical devices. Offic J Eur Communities 1993;L169:1-43.
    • (1993) Offic J Eur Communities , vol.L169 , pp. 1-43
  • 28
    • 0002931369 scopus 로고
    • Mapping of the radiofrequency field
    • Insko EK, Bolinger L. Mapping of the radiofrequency field. J Magn Reson A 1993;103:82-85.
    • (1993) J Magn Reson A , vol.103 , pp. 82-85
    • Insko, E.K.1    Bolinger, L.2
  • 29
    • 0029952944 scopus 로고    scopus 로고
    • Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow
    • Alsop DC, Detre JA. Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow. J Cereb Blood Flow Metab 1996;16:1236-1249. (Pubitemid 26365376)
    • (1996) Journal of Cerebral Blood Flow and Metabolism , vol.16 , Issue.6 , pp. 1236-1249
    • Alsop, D.C.1    Detre, J.A.2
  • 31
    • 0021991039 scopus 로고
    • What is the correct value for the brain blood partition-coefficient for water?
    • Herscovitch P, Raichle ME. What is the correct value for the brain blood partition-coefficient for water? J Cereb Blood Flow Metab 1985;5:5-69.
    • (1985) J Cereb Blood Flow Metab , vol.5 , pp. 5-69
    • Herscovitch, P.1    Raichle, M.E.2
  • 32
    • 0034038214 scopus 로고    scopus 로고
    • Reduced power multislice MDEFT imaging
    • DOI 10.1002/(SICI)1522-2586(200004)11:4<445::AID-JMRI13>3.0.CO;2-T
    • Norris DG. Reduced power multislice MDEFT imaging. J Magn Reson Imaging 2000;11:445-451. (Pubitemid 30185885)
    • (2000) Journal of Magnetic Resonance Imaging , vol.11 , Issue.4 , pp. 445-451
    • Norris, D.G.1
  • 34
    • 66749181405 scopus 로고    scopus 로고
    • A simple and effective decoupling circuit for three-RF-coil ASL MRI experiments
    • abstract 1361
    • Li L, Zhang H, Ji T, Wyrwicz AM. A simple and effective decoupling circuit for three-RF-coil ASL MRI experiments. In: Proc 11th Annual Meeting ISMRM, Kyoto; 2004 (abstract 1361).
    • (2004) Proc 11th Annual Meeting ISMRM, Kyoto
    • Li, L.1    Zhang, H.2    Ji, T.3    Wyrwicz, A.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.