메뉴 건너뛰기




Volumn 28, Issue 7, 2007, Pages 1304-1305

Assessment of collateral supply by two-coil continuous arterial spin labeling after coil occlusion of the internal carotid artery

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; ARTIFICIAL EMBOLISM; BRAIN BLOOD FLOW; CASE REPORT; DISSECTING ANEURYSM; ECHO PLANAR IMAGING; GRAY MATTER; HUMAN; INTERNAL CAROTID ARTERY ANEURYSM; INTERNAL CAROTID ARTERY OCCLUSION; LEFT HEMISPHERE; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; RADIOFREQUENCY RADIATION; RIGHT HEMISPHERE; SPIN LABELING;

EID: 34548183746     PISSN: 01956108     EISSN: None     Source Type: Journal    
DOI: 10.3174/ajnr.A0552     Document Type: Article
Times cited : (4)

References (12)
  • 1
    • 0028938324 scopus 로고
    • Endarterectomy for asymptomatic carotid artery stenosis
    • Executive Committee for the Asymptomatic Carotid Atherosclerosis Study
    • Executive Committee for the Asymptomatic Carotid Atherosclerosis Study. Endarterectomy for asymptomatic carotid artery stenosis. JAMA 1995;273:1421-28
    • (1995) JAMA , vol.273 , pp. 1421-1428
  • 2
    • 0033033852 scopus 로고    scopus 로고
    • Multislice perfusion and perfusion territory imaging in humans with separate label and image coils
    • Zaharchuk G, Ledden PJ, Kwong KK, et al. Multislice perfusion and perfusion territory imaging in humans with separate label and image coils. Magn Reson Med 1999;41:1093-98
    • (1999) Magn Reson Med , vol.41 , pp. 1093-1098
    • Zaharchuk, G.1    Ledden, P.J.2    Kwong, K.K.3
  • 3
    • 0036708137 scopus 로고    scopus 로고
    • Continuous arterial spin labeling using a local magnetic field gradient coil
    • Trampel R, Mildner T, Goerke U, et al. Continuous arterial spin labeling using a local magnetic field gradient coil. Magn Reson Med 2002;48:543-46
    • (2002) Magn Reson Med , vol.48 , pp. 543-546
    • Trampel, R.1    Mildner, T.2    Goerke, U.3
  • 4
    • 0037764001 scopus 로고    scopus 로고
    • Selective arterial spin labeling (SASL): Perfusion territory mapping of selected feeding arteries tagged using two-dimensional radiofrequency pulses
    • Davies NP, Jezzard P. Selective arterial spin labeling (SASL): perfusion territory mapping of selected feeding arteries tagged using two-dimensional radiofrequency pulses. Magn Reson Med 2003;49;1133-42
    • (2003) Magn Reson Med , vol.49 , pp. 1133-1142
    • Davies, N.P.1    Jezzard, P.2
  • 5
    • 10044224810 scopus 로고    scopus 로고
    • Brain perfusion territory imaging applying oblique-plane arterial spin labeling with a standard send/receive head coil
    • Werner R, Alfke K, Schaeffter T, et al. Brain perfusion territory imaging applying oblique-plane arterial spin labeling with a standard send/receive head coil. Magn Reson Med 2004;52:1443-47
    • (2004) Magn Reson Med , vol.52 , pp. 1443-1447
    • Werner, R.1    Alfke, K.2    Schaeffter, T.3
  • 6
    • 1842418806 scopus 로고    scopus 로고
    • Flow territory mapping of the cerebral arteries with regional perfusion MRI
    • Hendrikse J, van der Grond J, Lu H, et al. Flow territory mapping of the cerebral arteries with regional perfusion MRI. Stroke 2004;35:882-87
    • (2004) Stroke , vol.35 , pp. 882-887
    • Hendrikse, J.1    van der Grond, J.2    Lu, H.3
  • 7
    • 2942699891 scopus 로고    scopus 로고
    • Efficiency of flow-driven adiabatic spin inversion under realistic experimental conditions: A computer simulation
    • Trampel R, Jochimsen TH, Mildner T, et al. Efficiency of flow-driven adiabatic spin inversion under realistic experimental conditions: a computer simulation. Magn Reson Med 2004;51:1187-93
    • (2004) Magn Reson Med , vol.51 , pp. 1187-1193
    • Trampel, R.1    Jochimsen, T.H.2    Mildner, T.3
  • 9
    • 0037407695 scopus 로고    scopus 로고
    • Functional perfusion imaging using continuous arterial spin labeling with separate labeling and imaging coils at 3 T
    • Mildner T, Trampel R, Möller HE, et al, Functional perfusion imaging using continuous arterial spin labeling with separate labeling and imaging coils at 3 T. Magn Reson Med 2003;49:791-95
    • (2003) Magn Reson Med , vol.49 , pp. 791-795
    • Mildner, T.1    Trampel, R.2    Möller, H.E.3
  • 10
    • 0344900036 scopus 로고    scopus 로고
    • Precision of the CASL-perfusion MRI technique for the measurement of cerebral blood flow in whole brain and vascular territories
    • Floyd TF, Ratcliffe SJ, Wang J, et al. Precision of the CASL-perfusion MRI technique for the measurement of cerebral blood flow in whole brain and vascular territories. J Magn Reson Imaging 2003;18:649-55
    • (2003) J Magn Reson Imaging , vol.18 , pp. 649-655
    • Floyd, T.F.1    Ratcliffe, S.J.2    Wang, J.3
  • 11
    • 14844290242 scopus 로고    scopus 로고
    • Continuous arterial spin labeling at the human common carotid artery: The influence of transit times
    • Mildner T, Möller HE, Driesel W, et al. Continuous arterial spin labeling at the human common carotid artery: the influence of transit times. NMR Biomed 2005;18:19-23
    • (2005) NMR Biomed , vol.18 , pp. 19-23
    • Mildner, T.1    Möller, H.E.2    Driesel, W.3
  • 12
    • 0036325034 scopus 로고    scopus 로고
    • Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 tesla
    • Wang J, Alsop DC, Li L, et al. Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 tesla. Magn Reson Med 2002;48:242-54
    • (2002) Magn Reson Med , vol.48 , pp. 242-254
    • Wang, J.1    Alsop, D.C.2    Li, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.