-
1
-
-
0027690838
-
Dynamic gadolinium-enhanced three-dimensional abdominal MR arteriography
-
Prince MR, Yucel EK, Kaufman JA, Harrison DC, Geller SC. Dynamic gadolinium-enhanced three-dimensional abdominal MR arteriography. J Magn Reson Imaging 1993;3:877-881.
-
(1993)
J Magn Reson Imaging
, vol.3
, pp. 877-881
-
-
Prince, M.R.1
Yucel, E.K.2
Kaufman, J.A.3
Harrison, D.C.4
Geller, S.C.5
-
2
-
-
0023740742
-
MR fluoroscopy: Technical feasibility
-
DOI 10.1002/mrm.1910080102
-
Riederer SJ, Tasciyan T, Farzaneh F, Lee JN, Wright RC, Herfkens RJ. MR fluoroscopy: technical feasibility. Magn Reson Med 1988;8:1-15. (Pubitemid 18236283)
-
(1988)
Magnetic Resonance in Medicine
, vol.8
, Issue.1
, pp. 1-15
-
-
Riederer, S.J.1
Tasciyan, T.2
Farzaneh, F.3
Lee, J.N.4
Wright, R.C.5
Herfkens, R.J.6
-
3
-
-
0027381155
-
Generalized matched filtering for time-resolved MR angiography of pulsatile flow
-
DOI 10.1002/mrm.1910300511
-
Wang Y, Weber DM, Korosec FR, Mistretta CA, Grist TM, Swan JS, Turski PA. Generalized matched filtering for time-resolved MR angiography of pulsatile flow. Magn Reson Med 1993;30:600-608. (Pubitemid 23317317)
-
(1993)
Magnetic Resonance in Medicine
, vol.30
, Issue.5
, pp. 600-608
-
-
Wang, Y.1
Weber, D.M.2
Korosec, F.R.3
Mistretta, C.A.4
Grist, T.M.5
Swan, J.S.6
Turski, P.A.7
-
4
-
-
0030183445
-
The effects of time varying intravascular signal intensity and k-space acquisition order on three-dimensional MR angiography image quality
-
Maki JH, Prince MR, Londy FJ, Chenevert TL. The effects of time varying intravascular signal intensity and k-space acquisition order on three-dimensional MR angiography image quality. J Magn Reson Imaging 1996;6:642-651. (Pubitemid 126701436)
-
(1996)
Journal of Magnetic Resonance Imaging
, vol.6
, Issue.4
, pp. 642-651
-
-
Maki, J.H.1
Prince, M.R.2
Lonely, F.J.3
Chenevert, T.L.4
-
5
-
-
0029805810
-
Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector
-
Earls JP, Rofsky NM, DeCorato DR, Krinsky GA, Weinreb JC. Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: usefulness of a timing examination and MR power injector. Radiology 1996;201:705-710. (Pubitemid 26392618)
-
(1996)
Radiology
, vol.201
, Issue.3
, pp. 705-710
-
-
Earls, J.P.1
Rofsky, N.M.2
Decorato, D.R.3
Krinsky, G.A.4
Weinreb, J.C.5
-
6
-
-
0030893848
-
Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography
-
Foo TK, Saranathan M, Prince MR, Chenevert TL. Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography. Radiology 1997;203:275-280. (Pubitemid 27142744)
-
(1997)
Radiology
, vol.203
, Issue.1
, pp. 275-280
-
-
Foo, T.K.F.1
Saranathan, M.2
Prince, M.R.3
Chenevert, T.L.4
-
7
-
-
0030770299
-
Fluoroscopically triggered contrast-enhanced three-dimensional MR angiography with elliptical centric view order: Application to the renal arteries
-
Wilman AH, Riederer SJ, King BF, Debbins JP, Rossman PJ, Ehman RL. Fluoroscopically triggered contrast-enhanced three-dimensional MR angiography with elliptical centric view order: application to the renal arteries. Radiology 1997;205:137-146. (Pubitemid 27415138)
-
(1997)
Radiology
, vol.205
, Issue.1
, pp. 137-146
-
-
Wilman, A.H.1
Riederer, S.J.2
King, B.F.3
Debbins, J.P.4
Rossman, P.J.5
Ehman, R.L.6
-
8
-
-
0031908601
-
Peripheral vascular tree stenoses: Evaluation with moving-bed infusion- Tracking MR angiography
-
Ho KY, Leiner T, de Haan MW, Kessels AG, Kitslaar PJ, van Engelshoven JM. Peripheral vascular tree stenoses: evaluation with moving-bed infusion-tracking MR angiography. Radiology 1998;206:683-692. (Pubitemid 28128515)
-
(1998)
Radiology
, vol.206
, Issue.3
, pp. 683-692
-
-
Ho, K.Y.J.A.M.1
Leiner, T.2
De Haan, M.W.3
Kessels, A.G.H.4
Kitslaar, P.J.E.H.M.5
Van Engelshoven, J.M.A.6
-
9
-
-
0032471072
-
Contrast-enhanced magnetic resonance angiography of the renal arteries. Original investigation
-
Hany TF, Leung DA, Pfammatter T, Debatin JF. Contrast-enhanced magnetic resonance angiography of the renal arteries. Original investigation. Invest Radiol 1998;33:653-659.
-
(1998)
Invest Radiol
, vol.33
, pp. 653-659
-
-
Hany, T.F.1
Leung, D.A.2
Pfammatter, T.3
Debatin, J.F.4
-
10
-
-
0032930455
-
Stepping-table gadolinium-enhanced digital subtraction MR angiography of the aorta and lower extremity arteries: Preliminary experience
-
Meaney JF, Ridgway JP, Chakraverty S, Robertson I, Kessel D, Radjenovic A, Kouwenhoven M, Kassner A, Smith MA. Stepping-table gadolinium-enhanced digital subtraction MR angiography of the aorta and lower extremity arteries: preliminary experience. Radiology 1999;211:59-67. (Pubitemid 29161734)
-
(1999)
Radiology
, vol.211
, Issue.1
, pp. 59-67
-
-
Meaney, J.F.M.1
Ridgway, J.P.2
Chakraverty, S.3
Robertson, I.4
Kessel, D.5
Radjenovic, A.6
Kouwenhoven, M.7
Kassner, A.8
Smith, M.A.9
-
11
-
-
0032846557
-
Contrast-enhanced MR angiography of the carotid bifurcation
-
DOI 10.1002/(SICI)1522-2586(199909)10:3<317::AID-JMRI14>3.0.CO;2-M
-
Korosec FR, Turski PA, Carroll TJ, Mistretta CA, Grist TM. Contrast-enhanced MR angiography of the carotid bifurcation. J Magn Reson Imaging 1999;10:317-325. (Pubitemid 29463116)
-
(1999)
Journal of Magnetic Resonance Imaging
, vol.10
, Issue.3
, pp. 317-325
-
-
Korosec, F.R.1
Turski, P.A.2
Carroll, T.J.3
Mistretta, C.A.4
Grist, T.M.5
-
12
-
-
0036158390
-
Continuously moving table data acquisition method for long FOV contrast-enhanced MRA and whole-body MRI
-
DOI 10.1002/mrm.10061
-
Kruger DG, Riederer SJ, Grimm RC, Rossman PJ. Continuously moving table data acquisition method for long FOV contrast-enhanced MRA and whole-body MRI. Magn Reson Med 2002;47:224-231. (Pubitemid 34116789)
-
(2002)
Magnetic Resonance in Medicine
, vol.47
, Issue.2
, pp. 224-231
-
-
Kruger, D.G.1
Riederer, S.J.2
Grimm, R.C.3
Rossman, P.J.4
Minnesota5
-
13
-
-
0036720426
-
Thorax: Low-dose contrast-enhanced three-dimensional MR angiography with subsecond temporal resolution-initial results
-
Finn JP, Baskaran V, Carr JC, McCarthy RM, Pereles FS, Kroeker R, Laub GA. Thorax: low-dose contrast-enhanced three-dimensional MR angiography with subsecond temporal resolution-initial results. Radiology 2002;224:896-904.
-
(2002)
Radiology
, vol.224
, pp. 896-904
-
-
Finn, J.P.1
Baskaran, V.2
Carr, J.C.3
McCarthy, R.M.4
Pereles, F.S.5
Kroeker, R.6
Laub, G.A.7
-
14
-
-
0037386443
-
Preoperative evaluation of the entire hepatic vasculature in living liver donors with use of contrast-enhanced MR angiography and true fast imaging with steady-state precession
-
Carr JC, Nemcek AA, Jr, Abecassis M, Blei A, Clarke L, Pereles FS, McCarthy R, Finn JP. Preoperative evaluation of the entire hepatic vasculature in living liver donors with use of contrast-enhanced MR angiography and true fast imaging with steady-state precession. J Vasc Interv Radiol 2003;14:441-449. (Pubitemid 36423165)
-
(2003)
Journal of Vascular and Interventional Radiology
, vol.14
, Issue.4
, pp. 441-449
-
-
Carr, J.C.1
Nemcek Jr., A.A.2
Abecassis, M.3
Blei, A.4
Clarke, L.5
Pereles, F.S.6
McCarthy, R.7
Finn, J.P.8
-
16
-
-
0022465686
-
A proposed grading system for arteriovenous malformations
-
Spetzler RF, Martin NA. A proposed grading system for arteriovenous malformations. J Neurosurg 1986;65:476-483. (Pubitemid 16000693)
-
(1986)
Journal of Neurosurgery
, vol.65
, Issue.4
, pp. 476-483
-
-
Spetzler, R.F.1
Martin, N.A.2
-
17
-
-
0023263036
-
Surgical management of large AVM's by staged embolization and operative excision
-
Spetzler RF, Martin NA, Carter LP, Flom RA, Raudzens PA, Wilkinson E. Surgical management of large AVM's by staged embolization and operative excision. J Neurosurg 1987;67:17-28. (Pubitemid 17085008)
-
(1987)
Journal of Neurosurgery
, vol.67
, Issue.1
, pp. 17-28
-
-
Spetzler, R.F.1
Martin, N.A.2
Carter, L.P.3
-
18
-
-
0033953603
-
Dynamic three-dimensional magnetic resonance abdominal angiography and perfusion: Implementation and preliminary experience
-
DOI 10.1002/(SICI)1522-2586(200002)11:2<201::AID-JMRI19>3.0.CO;2-4
-
Goldfarb JW, Prasad PV, Griswold MA, Edelman RR. Dynamic three-dimensional magnetic resonance abdominal angiography and perfusion: implementation and preliminary experience. J Magn Reson Imaging 2000;11:201-207. (Pubitemid 30080976)
-
(2000)
Journal of Magnetic Resonance Imaging
, vol.11
, Issue.2
, pp. 201-207
-
-
Goldfarb, J.W.1
Prasad, P.V.2
Griswold, M.A.3
Edelman, R.R.4
-
19
-
-
0030982409
-
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
-
DOI 10.1002/mrm.1910380414
-
Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997;38:591-603. (Pubitemid 27419224)
-
(1997)
Magnetic Resonance in Medicine
, vol.38
, Issue.4
, pp. 591-603
-
-
Sodickson, D.K.1
Manning, W.J.2
-
20
-
-
0032712873
-
SENSE: Sensitivity encoding for fast MRI
-
DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S
-
Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P. SENSE: sensitivity encoding for fast MRI. Magn Reson Med 1999;42:952-962. (Pubitemid 29521486)
-
(1999)
Magnetic Resonance in Medicine
, vol.42
, Issue.5
, pp. 952-962
-
-
Pruessmann, K.P.1
Weiger, M.2
Scheidegger, M.B.3
Boesiger, P.4
-
21
-
-
0034538104
-
Contrast-enhanced 3D MR angiography with simultaneous acquisition of spatial harmonics: A pilot study
-
Sodickson DK, McKenzie CA, Li W, Wolff S, Manning WJ, Edelman RR. Contrast-enhanced 3D MR angiography with simultaneous acquisition of spatial harmonics: a pilot study. Radiology 2000;217:284-289. (Pubitemid 33097615)
-
(2000)
Radiology
, vol.217
, Issue.1
, pp. 284-289
-
-
Sodickson, D.K.1
McKenzie, C.A.2
Li, W.3
Wolff, S.4
Manning, W.J.5
Edelman, R.R.6
-
22
-
-
0033760130
-
Contrast-enhanced 3D MRA using SENSE
-
Weiger M, Pruessmann KP, Kassner A, Roditi G, Lawton T, Reid A, Boesiger P. Contrast-enhanced 3D MRA using SENSE. J Magn Reson Imaging 2000;12:671-677.
-
(2000)
J Magn Reson Imaging
, vol.12
, pp. 671-677
-
-
Weiger, M.1
Pruessmann, K.P.2
Kassner, A.3
Roditi, G.4
Lawton, T.5
Reid, A.6
Boesiger, P.7
-
23
-
-
0036263907
-
Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA)
-
DOI 10.1002/mrm.10171
-
Griswold MA, Jakob PM, Heidemann RM, Nittka M, Jellus V, Wang J, Kiefer B, Haase A. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 2002;47:1202-1210. (Pubitemid 34587412)
-
(2002)
Magnetic Resonance in Medicine
, vol.47
, Issue.6
, pp. 1202-1210
-
-
Griswold, M.A.1
Jakob, P.M.2
Heidemann, R.M.3
Nittka, M.4
Jellus, V.5
Wang, J.6
Kiefer, B.7
Haase, A.8
-
24
-
-
35948971793
-
4D radial contrast-enhanced MR angiography with sliding subtraction
-
DOI 10.1002/mrm.21364
-
Cashen TA, Jeong H, Shah MK, Bhatt HM, Shin W, Carr JC, Walker MT, Batjer HH, Carroll TJ. 4D radial contrast-enhanced MR angiography with sliding subtraction. Magn Reson Med 2007;58:962-972. (Pubitemid 350074364)
-
(2007)
Magnetic Resonance in Medicine
, vol.58
, Issue.5
, pp. 962-972
-
-
Cashen, T.A.1
Jeong, H.2
Shah, M.K.3
Bhatt, H.M.4
Shin, W.5
Carr, J.C.6
Walker, M.T.7
Batjer, H.H.8
Carroll, T.J.9
-
26
-
-
0033971791
-
Undersampled projection reconstruction applied to MR angiography
-
DOI 10.1002/(SICI)1522-2594(200001)43:1<91::AID-MRM11>3.0.CO;2-4
-
Peters DC, Korosec FR, Grist TM, Block WF, Holden JE, Vigen KK, Mistretta CA. Undersampled projection reconstruction applied to MR angiography. Magn Reson Med 2000;43:91-101. (Pubitemid 30027116)
-
(2000)
Magnetic Resonance in Medicine
, vol.43
, Issue.1
, pp. 91-101
-
-
Peters, D.C.1
Korosec, F.R.2
Grist, T.M.3
Block, W.F.4
Holden, J.E.5
Vigen, K.K.6
Mistretta, C.A.7
-
27
-
-
30344488447
-
Highly constrained backprojection for time-resolved MRI
-
DOI 10.1002/mrm.20772
-
Mistretta CA, Wieben O, Velikina J, Block W, Perry J, Wu Y, Johnson K. Highly constrained backprojection for time-resolved MRI. Magn Reson Med 2006;55:30-40. (Pubitemid 43062925)
-
(2006)
Magnetic Resonance in Medicine
, vol.55
, Issue.1
, pp. 30-40
-
-
Mistretta, C.A.1
Wieben, O.2
Velikina, J.3
Block, W.4
Perry, J.5
Wu, Y.6
Johnson, K.7
Wu, Y.8
-
28
-
-
36448951564
-
3D time-resolved contrast-enhanced cerebrovascular MR angiography with subsecond frame update times using radial k-space trajectories and highly constrained projection reconstruction
-
DOI 10.3174/ajnr.A0772
-
Wu Y, Kim N, Korosec FR, Turk A, Rowley HA, Wieben O, Mistretta CA, Turski PA. 3D time-resolved contrast-enhanced cerebrovascular MR angiography with subsecond frame update times using radial k-space trajectories and highly constrained projection reconstruction. AJNR Am J Neuroradiol 2007;28:2001-2004. (Pubitemid 350174751)
-
(2007)
American Journal of Neuroradiology
, vol.28
, Issue.10
, pp. 2001-2004
-
-
Wu, Y.1
Kim, N.2
Korosec, F.R.3
Turk, A.4
Rowley, H.A.5
Wieben, O.6
Mistretta, C.A.7
Turski, P.A.8
-
29
-
-
34547941998
-
Time-resolved MR angiography with limited projections
-
DOI 10.1002/mrm.21312
-
Huang Y, Wright GA. Time-resolved MR angiography with limited projections. Magn Reson Med 2007;58:316-325. (Pubitemid 47267649)
-
(2007)
Magnetic Resonance in Medicine
, vol.58
, Issue.2
, pp. 316-325
-
-
Huang, Y.1
Wright, G.A.2
-
30
-
-
32544437989
-
Characterizing radial undersampling artifacts for cardiac applications
-
DOI 10.1002/mrm.20782
-
Peters DC, Rohatgi P, Botnar RM, Yeon SB, Kissinger KV, Manning WJ. Characterizing radial undersampling artifacts for cardiac applications. Magn Reson Med 2006;55:396-403. (Pubitemid 43238109)
-
(2006)
Magnetic Resonance in Medicine
, vol.55
, Issue.2
, pp. 396-403
-
-
Peters, D.C.1
Rohatgi, P.2
Botnar, R.M.3
Yeon, S.B.4
Kissinger, K.V.5
Manning, W.J.6
-
31
-
-
37549061019
-
More optimal HYPR reconstructions using a combination of HYPR and conjugate-gradient minimization
-
(Abstract 834).
-
Griswold MA, Barkauskas K, Blaimer M, Sunshine JL, Duerk JL. More optimal HYPR reconstructions using a combination of HYPR and conjugate-gradient minimization. In: Proceedings of the 15th Annual Meeting of ISMRM, Berlin, Germany, 2007 (Abstract 834).
-
(2007)
Proceedings of the 15th Annual Meeting of ISMRM, Berlin, Germany
-
-
Griswold, M.A.1
Barkauskas, K.2
Blaimer, M.3
Sunshine, J.L.4
Duerk, J.L.5
-
32
-
-
66149134234
-
Fast parallel image reconstruction for non-Cartesian trajectories
-
(Abstract 2347).
-
Heidemann RM, Griswold MA, Jakob PM. Fast parallel image reconstruction for non-Cartesian trajectories. In: Proceedings of the 11th Annual Meeting of ISMRM, Toronto, Canada, 2003 (Abstract 2347).
-
(2003)
Proceedings of the 11th Annual Meeting of ISMRM, Toronto, Canada
-
-
Heidemann, R.M.1
Griswold, M.A.2
Jakob, P.M.3
-
33
-
-
33845243474
-
Hybird radial-parallel 3D imaging
-
(Abstract 13).
-
Cashen TA, Carroll TJ. Hybird radial-parallel 3D imaging. In: Proceedings of the 13th Annual Meeting of ISMRM, Miami Beach, FL, USA, 2005 (Abstract 13).
-
(2005)
Proceedings of the 13th Annual Meeting of ISMRM, Miami Beach, FL, USA
-
-
Cashen, T.A.1
Carroll, T.J.2
|